Artigo em Inglês | MEDLINE | ID: mdl-32047029

RESUMO

BACKGROUND: The original bubble continuous positive airway pressure (bCPAP) design has wide-bore tubing and a low-resistance interface. This creates a stable airway pressure that is reflected by the submersion depth of the expiratory tubing. Several systems with alterations to the original bCPAP design are now available. Most of these are aimed for use in low-income and middle-income countries and have not been compared with the original design. OBJECTIVE: We identified three major alterations to the original bCPAP design: (1) resistance of nasal interface, (2) volume of dead space and (3) diameter of expiratory tubing. Our aim was to study the effect of these alterations on CPAP delivery and work of breathing in a mechanical lung model. Dead space should always be avoided and was not further tested. METHODS: The effect of nasal interface resistance and expiratory tubing diameter was evaluated with simulated breathing in a mechanical lung model without interface leakage. The main outcome was delivered CPAP and imposed work of breathing. RESULTS: High-resistance interfaces and narrow expiratory tubing increased the work of breathing. Additionally, narrow expiratory tubing resulted in higher CPAP levels than indicated by the submersion depth. CONCLUSION: Our study shows the significant effect on CPAP delivery and imposed work of breathing when using high-resistance interfaces and narrow expiratory tubing in bCPAP systems. New systems should include low-resistance interfaces and wide-bore tubing and be compared with the original bCPAP. Referring to all systems that bubble as bCPAP is misleading and potentially hazardous.

2.
Lakartidningen ; 1162019 Oct 08.
Artigo em Sueco | MEDLINE | ID: mdl-31593285

RESUMO

The recently documented high survival of extremely preterm infants in Sweden is related to a high degree of centralization of pre- and postnatal care and to recently issued national consensus guidelines providing recommendations for perinatal care at 22-24 gestational weeks. The prevalence of major neonatal morbidity remains high and exceeded 60 % in a recent study of extremely preterm infants born at < 27 gestational weeks delivered in Sweden in 2014-2016 and surviving to 1 year of age. Damage to immature organ systems inflicted during the neonatal period causes varying degrees of functional impairment with lasting effects in the growing child. There is an urgent need for evidence-based novel interventions aiming to prevent neonatal morbidity with a subsequent improvement of long-term outcome.


Assuntos
Lactente Extremamente Prematuro , Doenças do Prematuro , Nascimento Prematuro , Displasia Broncopulmonar/epidemiologia , Displasia Broncopulmonar/fisiopatologia , Displasia Broncopulmonar/prevenção & controle , Serviços Centralizados no Hospital , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Hemorragia Cerebral/fisiopatologia , Hemorragia Cerebral/prevenção & controle , Ventrículos Cerebrais/irrigação sanguínea , Ventrículos Cerebrais/diagnóstico por imagem , Enterocolite Necrosante/epidemiologia , Enterocolite Necrosante/fisiopatologia , Enterocolite Necrosante/prevenção & controle , Feminino , Humanos , Fenômenos Fisiológicos da Nutrição do Lactente , Recém-Nascido , Doenças do Prematuro/epidemiologia , Doenças do Prematuro/fisiopatologia , Doenças do Prematuro/prevenção & controle , Assistência Perinatal/organização & administração , Gravidez , Nascimento Prematuro/mortalidade , Retinopatia da Prematuridade/sangue , Retinopatia da Prematuridade/epidemiologia , Retinopatia da Prematuridade/fisiopatologia , Retinopatia da Prematuridade/prevenção & controle , Taxa de Sobrevida , Suécia/epidemiologia
3.
Pediatr Pulmonol ; 54(5): 602-609, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30887678

RESUMO

AIM: The ratio of ventilation to blood flow is an important determinant for regional gas exchange in the lung and hypoxemia is one of the clinical hallmarks in infants with bronchopulmonary dysplasia (BPD). We have previously demonstrated ventilation/perfusion ratio (V/Q) abnormalities in infants with BPD at 36 weeks postconceptional age. The status of V/Q matching in older children with a history of BPD in infancy is unknown. In this study, we examined if 10-year-old children with a history of BPD had V/Q impairments. METHODS: Three-dimensional V/Q-scintigraphy (SPECT) was performed in 26 children. RESULTS: In the BPD group, lung volume with mismatch, (V>Q) was larger compared to areas with reverse mismatch (Q>V), 26.2% and 11.8%, respectively, implying that perfusion defects contribute more than ventilation defects in the V/Q mismatch. Also, the mean fractional distribution of V and Q to V/Q in children with BPD was reduced compared to healthy children, 31% and 51% compared to 64% and 89%, respectively (P < 0.01). CONCLUSION: At 10 years of age children with a history of BPD had ventilation/perfusion abnormalities, with prominent perfusion defects. These V/Q abnormalities suggest the presence of residual alveolar-capillary impairment.


Assuntos
Displasia Broncopulmonar/fisiopatologia , Pulmão/fisiopatologia , Relação Ventilação-Perfusão , Displasia Broncopulmonar/diagnóstico por imagem , Estudos de Casos e Controles , Criança , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Ventilação Pulmonar , Volume de Ventilação Pulmonar , Tomografia Computadorizada de Emissão de Fóton Único , Cintilografia de Ventilação/Perfusão
4.
Acta Paediatr ; 108(1): 62-69, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29999201

RESUMO

AIM: This study evaluated if oral supplementation with the probiotic bacterium Lactobacillus reuteri DSM 17938 improved enteral feeding tolerance and growth rates in extremely low birthweight (ELBW) infants. METHOD: A randomised, double-blind, placebo-controlled trial comprising 134 ELBW (<1000 g) infants born before gestational week 28 + 0. Daily supplementation of L. reuteri (1.25 × 108 bacteria/day) or placebo started within 3 days and continued until gestational week 36 + 0. Primary outcome was feeding tolerance and secondary outcome growth rate calculated as z-score development. RESULTS: Feeding tolerance was similar in the probiotic and placebo group. Time to full enteral feeds was 15 days in both groups. The z-score of the head circumference decreased in both groups from birth to day 28 of life, but it decreased less in the L. reuteri group compared to the placebo group: -1.2 SD (95% CI: -1.4 to -1.0) versus -1.7 SD (95% CI: -2.0 to -1.5; p = 0.001). Other growth parameters were similar in the study groups. CONCLUSION: Lactobacillus reuteri did not reduce time to reach full enteral feeds in ELBW infants. The L. reuteri supplemented infants, however, had a better growth rate of the head during the first month of life.

5.
Mater Sci Eng C Mater Biol Appl ; 93: 782-789, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30274112

RESUMO

Ventilator associated pneumonia and sepsis are frequent complications in neonatal care. Bacterial colonization of medical devices and interfaces used for respiratory support may contribute by functioning as a bacterial reservoir seeding bacteria into airways. We have developed an antibacterial surface coating based on a cysteine ligand covalently coupled via a spacer to a carboxylic backbone layer on an acrylic acid grafted silicone surface. This coating was applied on a commercially available nasal prong and the antibacterial effect was evaluated both in vitro and in vivo in a first-in-human phase 1 trial. The coated nasal prongs had strong antibacterial activity against both Gram-negative and Gram-positive bacteria in vitro. In a randomized pre-clinical trial study of 24 + 24 healthy adult volunteers who carried coated or non-coated nasal prongs for 18 h, a 10log difference in mean bacterial colonization of 5.82 (p < 0.0001) was observed. These results show that this coating technique can prevent colonization by the normal skin and mucosal flora, and thus represent a promising novel technology for reduction of medical device-associated hospital acquired infections.


Assuntos
Antibacterianos/química , Materiais Revestidos Biocompatíveis/química , Bactérias Gram-Negativas/crescimento & desenvolvimento , Bactérias Gram-Positivas/crescimento & desenvolvimento , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Respiração Artificial/instrumentação , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia Associada à Ventilação Mecânica/microbiologia
6.
Nutrients ; 10(10)2018 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-30347801

RESUMO

Difference in human milk oligosaccharides (HMO) composition in breast milk may be one explanation why some preterm infants develop necrotizing enterocolitis (NEC) despite being fed exclusively with breast milk. The aim of this study was to measure the concentration of 15 dominant HMOs in breast milk during the neonatal period and investigate how their levels correlated to NEC, sepsis, and growth in extremely low birth weight (ELBW; <1000 g) infants who were exclusively fed with breast milk. Milk was collected from 91 mothers to 106 infants at 14 and 28 days and at postmenstrual week 36. The HMOs were analysed with high-performance anion-exchange chromatography with pulsed amperometric detection. The HMOs diversity and the levels of Lacto-N-difucohexaose I were lower in samples from mothers to NEC cases, as compared to non-NEC cases at all sampling time points. Lacto-N-difucohexaose I is only produced by secretor and Lewis positive mothers. There were also significant but inconsistent associations between 3'-sialyllactose and 6'-sialyllactose and culture-proven sepsis and significant, but weak correlations between several HMOs and growth rate. Our results suggest that the variation in HMO composition in breast milk may be an important factor explaining why exclusively breast milk fed ELBW infants develop NEC.


Assuntos
Enterocolite Necrosante/etiologia , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Leite Humano/química , Oligossacarídeos/efeitos adversos , Oligossacarídeos/classificação , Humanos , Recém-Nascido , Oligossacarídeos/química
7.
Pediatrics ; 142(Suppl 1): S533-S538, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30171138

RESUMO

Sweden has a long tradition of being at the forefront of the management of extremely preterm infants. In this article, we explore the historical background, ethical discussions, and evidence from national surveys combined with data from quality registers that form the background of the current Swedish guidelines for the care of extremely preterm infants. The current Swedish national guidelines suggest providing active care for preterm infants from 23 weeks' gestation and considering active care from 22 weeks' gestation. The survival of infants in gestational weeks 22 and 23 has increased and now exceed 50% and 60%, respectively; importantly, the Swedish proactive approach to care at the border of viability has not resulted in an increased proportion of functional impairment among survivors.


Assuntos
Gerenciamento Clínico , Viabilidade Fetal/fisiologia , Cuidado do Lactente/ética , Lactente Extremamente Prematuro/fisiologia , Doenças do Prematuro/epidemiologia , Doenças do Prematuro/terapia , Humanos , Cuidado do Lactente/métodos , Cuidado do Lactente/tendências , Recém-Nascido , Sistema de Registros/ética , Taxa de Sobrevida/tendências , Suécia/epidemiologia
9.
Acta Paediatr ; 106(11): 1760-1766, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28715132

RESUMO

AIM: Medijet nasal continuous positive airway pressure (CPAP) generators are a family of devices developed from the Benveniste valve. Previous studies have shown that the in vitro performance of the Medijet disposable generator was similar to the Neopuff resistor system. We hypothesised that resistance would be the main mechanism of CPAP generation in the Medijet disposable generator. METHODS: The in vitro performance of the Medijet reusable and disposable systems, the Neopuff resistor system and the Benveniste and Infant Flow nonresistor systems were investigated using static and dynamic bench tests. RESULTS: Large differences in performance were found between the different systems. The disposable Medijet demonstrated high resistance, low pressure stability and high imposed work of breathing. The results also showed that encapsulating the Benveniste valve changed it into a resistor system. CONCLUSION: The main mechanism of CPAP generation for the disposable Medijet generator was resistance. The Medijet device family showed increasing resistance with each design generation. The high resistance of the Medijet disposable generator could be of great value when examining the clinical importance of pressure stability. Our results suggest that this device should be used cautiously in patients where pressure-stable CPAP is believed to be clinically important.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Humanos , Recém-Nascido , Ventilação Pulmonar
10.
Arch Dis Child Fetal Neonatal Ed ; 102(3): F203-F207, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27553588

RESUMO

OBJECTIVE: T-piece resuscitation systems are pressure unstable and have high imposed work of breathing (iWOB). Pressure stable respiratory support with low iWOB might improve outcome. We have developed a new resuscitation system that can be used with nasal prongs or face mask. The aim of the study was to describe the in vitro performance of the new system and to perform a clinical feasibility trial of initial stabilisation of preterm infants. METHOD: A mechanical lung model was used to determine iWOB at increasing levels of continuous positive airway pressure (CPAP). The feasibility trial included 36 infants (27-34 weeks of gestation), who were randomised into three groups (T-piece, new system with face mask or new system with prongs). Collected data included problems with usage, safety, time to stable breathing, need for positive pressure ventilation and intubation. RESULTS: In the mechanical lung model, the new system reduced iWOB with 91.5% (mask) and 86.6% (medium prongs) compared with Neopuff (4 cm CPAP, p<0.001). Informed consent was obtained from 45 patients, 39 were randomised and 36 needed support. Randomisation resulted in an imbalance: The group of new system infants had lower gestational age compared with the T-piece group. Thirteen patients needed positive pressure ventilation (median 20 cm H2O). One infant was intubated. The study did not reveal problems with the equipment or safety. CONCLUSIONS: Compared with T-piece systems, the new system had a marked reduction in iWOB in bench tests. The feasibility trial did not reveal problems with usability or safety.


Assuntos
Cuidado do Lactente/métodos , Recém-Nascido Prematuro/fisiologia , Máscaras , Ressuscitação/métodos , Trabalho Respiratório/fisiologia , Índice de Apgar , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Estudos de Viabilidade , Feminino , Humanos , Recém-Nascido , Masculino , Modelos Anatômicos , Pneumotórax/etiologia , Respiração com Pressão Positiva/efeitos adversos , Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/métodos , Ressuscitação/efeitos adversos , Ressuscitação/instrumentação
11.
Acta Paediatr ; 106(3): 382-386, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27992064

RESUMO

AIM: Less invasive surfactant administration (LISA), namely surfactant instillation through a thin catheter in the trachea during spontaneous breathing, is increasingly used for premature infants. We surveyed the use of this technique in the Nordic countries in autumn 2015. METHODS: A link to a web-based survey of surfactant administration methods was emailed to the directors of all neonatal units in the Nordic Region, apart from Finland, where only the five university-based departments were invited. RESULTS: Of the 73 units (85%) who responded, 23 (32%) said that they used LISA. The country rates were Iceland 100%, Norway 82%, Finland 60%, Denmark, including Faroe Island and Greenland, 11% and Sweden 9%. LISA was used in 62% of level three units, but only 14% of level two units and most commonly in babies with a gestational age of at least 26 weeks. Premedication was always or sometimes used by 78%. The main reasons for not using LISA were lack of familiarity with the technique (61%), no perceived benefit over other methods (22%) and concerns about patient discomfort (26%). CONCLUSION: Less invasive surfactant administration was used in 32% of Nordic neonatal units, most commonly in level three units. Premedication was used more often than previously reported.


Assuntos
Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Terapia Intensiva Neonatal/métodos , Terapia Intensiva Neonatal/estatística & dados numéricos , Neonatologia/métodos , Neonatologia/estatística & dados numéricos , Países Escandinavos e Nórdicos , Inquéritos e Questionários
12.
PLoS One ; 10(7): e0133432, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26192188

RESUMO

BACKGROUND: The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. METHODS: Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. RESULTS: The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. CONCLUSION: The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Trabalho Respiratório , Humanos , Recém-Nascido , Volume de Ventilação Pulmonar
13.
Respir Care ; 60(7): 1000-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25715346

RESUMO

BACKGROUND: Nasal CPAP is the most common respiratory support for neonates. Several factors are considered important for effective treatment, including leaks at the patient interface and the delivery of pressure-stable CPAP. Investigations of pressure stability during leaks should include both the change in the mean delivered CPAP and the pressure variation during each breath. The aim of this study was to examine the response of ventilators delivering nasal CPAP when challenged with leaks at the patient interface. METHODS: Seven ventilators providing nasal CPAP at 4 cm H2O were challenged with leaks during simulated neonatal breathing. Leak was applied for 15 consecutive breaths at a constant level (1-4 L/min). RESULTS: The 2 aspects of pressure stability were evaluated by measuring the mean delivered CPAP and the amplitude of pressure swings before, during, and after leaks. The ability to maintain the delivered CPAP and the amplitude of pressure swings varied greatly among the 7 ventilators before, during, and after leaks. Four of the ventilators tested have built-in leak compensation. CONCLUSIONS: There was no simple relationship between maintaining delivered CPAP during leaks and providing CPAP with low pressure swing amplitude. Maintaining the delivered CPAP and providing this without pressure swings are 2 separate aspects of pressure stability, and investigations concerning the clinical importance of pressure stability should address both aspects. This study also shows that compensation for leaks does not necessarily provide pressure-stable CPAP.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Desenho de Equipamento , Falha de Equipamento , Ventiladores Mecânicos/estatística & dados numéricos , Pressão Positiva Contínua nas Vias Aéreas/normas , Humanos , Recém-Nascido , Nariz , Projetos Piloto
14.
Pediatrics ; 132(3): e695-703, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23940237

RESUMO

BACKGROUND AND OBJECTIVES: The European Union Nitric Oxide trial was designed to assess the potential benefits of inhaled nitric oxide (iNO) compared with placebo in infants with respiratory failure. This follow-up study evaluated respiratory, neurodevelopmental, and other outcomes for infants entered into the European Union Nitric Oxide trial to age 2 years. METHODS: In a multicenter, randomized, double-blind study, preterm infants born at <29 weeks' gestation with moderate respiratory failure were allocated to receive iNO (5 ppm) or placebo for 7 to 21 days. Subjects underwent assessments at 1 and 2 years corrected for prematurity. RESULTS: At 36 weeks' postmenstrual age, 696 of 792 infants were alive; 4 in the iNO arm subsequently died before age 2 years compared with 7 in the control arm. We evaluated 95% of the survivors at 12 months and 90% at 2 years. In the iNO arm, 244 of 363 (67.2%) infants had survived without disability at age 2 years compared with 270 of 374 (72.2%) who received placebo (P = .094). Mean (SD) cognitive composite scores (Bayley Scales of Infant and Toddler Development, third edition) were 94 (13) in the iNO group and 95 (14) in the placebo group; in the iNO group, 19% scored <85 and 9.5% developed cerebral palsy compared with 13.3% and 9%, respectively. There were no significant differences in hospitalizations overall or due to respiratory illness in use of home oxygen therapy or respiratory medications, in growth, or in other health outcomes. CONCLUSIONS: At 2 years of age, low-dose (5 ppm) iNO started early (<24 hours after birth) for a median of 20 days did not affect neurodevelopmental or other health outcomes.


Assuntos
Broncodilatadores/administração & dosagem , Óxido Nítrico/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Administração por Inalação , Pré-Escolar , União Europeia , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/mortalidade , Taxa de Sobrevida
15.
Pediatr Crit Care Med ; 14(4): e196-201, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23439462

RESUMO

OBJECTIVES: Nasal continuous positive airway pressure (NCPAP) is an established treatment for respiratory distress in neonates. Most modern ventilators are able to provide NCPAP. There have been no large studies examining the properties of NCPAP delivered by ventilators. The aim of this study was to compare pressure stability and imposed work of breathing (iWOB) for NCPAP delivered by ventilators using simulated neonatal breathing. DESIGN: Experimental in vitro study. SETTING: Research laboratory in Sweden. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: Neonatal breathing was simulated using a mechanical lung simulator. Seven ventilators were tested at different CPAP levels using two breath profiles. Pressure stability and iWOB were determined. Results from three ventilators revealed that they provided a slight pressure support. For these ventilators, iWOB could not be calculated. There were large differences in pressure stability and iWOB between the tested ventilators. For simulations using the 3.4-kg breath profile, the pressure swings around the mean pressure were more than five times greater, and iWOB more than four times higher, for the system with the highest measured values compared with the system with the lowest. Overall, the Fabian ventilator was the most pressure stable system. Evita XL and SERVO-i were found more pressure stable than Fabian in some simulations. The results for iWOB were in accordance with pressure stability for systems that allowed determination of this variable. CONCLUSIONS: Some of the tested ventilators unexpectedly provided a minor degree of pressure support. In terms of pressure stability, we have not found any advantages of ventilators as a group compared with Bubble CPAP, Neopuff, and variable flow generators that were tested in our previous study. The variation between individual systems is great within both categories. The clinical importance of these findings needs further investigation.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Ventiladores Mecânicos , Trabalho Respiratório , Humanos , Recém-Nascido , Pulmão/fisiologia , Modelos Biológicos , Pressão
16.
Pediatr Pulmonol ; 48(12): 1206-13, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23359534

RESUMO

Bronchopulmonary dysplasia (BPD) is a significant cause of morbidity in the preterm population. Clinical severity grading based on the need for supplemental oxygen and/or need for positive airway pressure at 36 weeks postmenstrual age does not yield reproducible predictive values for later pulmonary morbidity. Single photon emission computed tomography (SPECT) was used to measure the distribution of lung ventilation (V) and perfusion (Q) in 30 BPD preterm infants at a median age of 37 weeks postmenstrual age. The V and Q were traced with 5 MBq Technegas and Technetium-labeled albumin macro aggregates, respectively, and the V/Q match-mismatch was used to quantify the extent of lung function impairment. The latter was then compared with the clinical severity grading at 36 weeks, and time spent on mechanical ventilation, continuous positive airway pressure (CPAP) and supplemental oxygen. Of those with mild and moderate BPD 3/9 and 3/11 patients, respectively, showed significant V/Q mismatches. By contrast, 4/10 patients with severe BPD showed a satisfactory V/Q matching distribution. An unsatisfactory V/Q match was not correlated with time spent on supplemental oxygen or CPAP, but was significantly negatively correlated with time spent on mechanical ventilation. SPECT provides unique additional information about regional lung function. The results suggest that the current clinical severity grading can be improved and/or complemented with SPECT.


Assuntos
Displasia Broncopulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Relação Ventilação-Perfusão , Estudos de Coortes , Feminino , Idade Gestacional , Humanos , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Índice de Gravidade de Doença , Pertecnetato Tc 99m de Sódio
17.
Pediatr Crit Care Med ; 13(2): e113-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21946854

RESUMO

OBJECTIVE: Continuous positive airway pressure is an established treatment for respiratory distress in neonates. Continuous positive airway pressure has been applied to infants using an array of devices. The aim of this experimental study was to investigate the characteristics of seven continuous positive airway pressure systems using simulated breath profiles from newborns. DESIGN: Experimental in vitro study. SETTING: Research laboratory in Sweden. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: In vitro simulation of spontaneous neonatal breathing was achieved with a mechanical lung model. Simulation included two breath profiles, three levels of continuous positive airway pressure with and without short binasal prongs and different levels of constant leak. Pressure stability and imposed work of breathing were determined. Seven continuous positive airway pressure systems were tested. There were large differences in pressure stability and imposed work of breathing between tested continuous positive airway pressure systems. Neopuff and Medijet had the highest pressure instability and imposed work of breathing. Benveniste, Hamilton Universal (Arabella), and Bubble continuous positive airway pressure showed intermediate results. AirLife and Infant Flow had the lowest pressure instability and imposed work of breathing. AirLife and Infant Flow showed the least decrease in delivered pressure when challenged with constant leak. CONCLUSION: The seven tested continuous positive airway pressure systems showed large variations in pressure stability and imposed work of breathing. They also showed large differences in how well they maintain continuous positive airway pressure when exposed to leak. For most systems, imposed work of breathing increased with increasing continuous positive airway pressure level. The clinical importance of the difference in pressure stability is uncertain. Our results may facilitate the design of clinical studies examining the effect of pressure stability on outcome.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Modelos Biológicos , Trabalho Respiratório , Desenho de Equipamento , Humanos , Recém-Nascido
18.
J Pediatr Surg ; 46(11): 2047-53, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22075331

RESUMO

BACKGROUND/PURPOSE: Advances in management of patients with congenital diaphragmatic hernia (CDH) have improved mortality rates but with a risk of increased pulmonary morbidity. The prognosis for CDH survivors remains difficult to predict owing to the lack of adequate methods. We used single photon emission computed tomography (SPECT) to measure the regional distribution of ventilation and perfusion in CDH infants to quantify the degree of lung function impairment and relate it to neonatal clinical disease severity. METHODS: Single photon emission computed tomography was performed in 12 CDH infants at the mean age of six months. Ventilation and perfusion were traced with 5 MBq Technegas and technetium-labelled albumin macro-aggregates, respectively. Neonatal clinical data collected during the patient's stay in the pediatric intensive care unit was correlated with the SPECT data. RESULTS: Single photon emission computed tomography revealed varying degrees of ventilation-perfusion abnormalities which correlated with the presence of pulmonary artery hypertension, days on ventilator and days on extracorporeal membrane oxygenation. CONCLUSIONS: The grade of clinical disease severity in infants following CDH repair is closely related to the ventilation-perfusion abnormality as seen using SPECT. The persistence of pulmonary artery hypertension into the postoperative neonatal period appears to be an important pathophysiological factor related to ventilation-perfusion abnormalities. Single photon emission computed tomography provides valuable clinical information for patient follow-up.


Assuntos
Hérnias Diafragmáticas Congênitas , Doenças do Prematuro/fisiopatologia , Pulmão/diagnóstico por imagem , Ventilação Pulmonar , Tomografia Computadorizada de Emissão de Fóton Único , Oxigenação por Membrana Extracorpórea , Hérnia Diafragmática/complicações , Hérnia Diafragmática/diagnóstico por imagem , Hérnia Diafragmática/fisiopatologia , Hérnia Diafragmática/cirurgia , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/diagnóstico por imagem , Oxigenoterapia , Compostos Radiofarmacêuticos , Pertecnetato Tc 99m de Sódio , Agregado de Albumina Marcado com Tecnécio Tc 99m , Relação Ventilação-Perfusão
19.
Lancet ; 376(9738): 346-54, 2010 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-20655106

RESUMO

BACKGROUND: In animal models, inhaled nitric oxide improved gas exchange and lung structural development, but its use in premature infants at risk of developing bronchopulmonary dysplasia remains controversial. We therefore tested the hypothesis that inhaled nitric oxide at a low concentration, started early and maintained for an extended period in babies with mild respiratory failure, might reduce the incidence of bronchopulmonary dysplasia. METHODS: 800 preterm infants with a gestational age at birth of between 24 weeks and 28 weeks plus 6 days (inclusive), weighing at least 500 g, requiring surfactant or continuous positive airway pressure for respiratory distress syndrome within 24 h of birth were randomly assigned in a one-to-one ratio to inhaled nitric oxide (5 parts per million) or placebo gas (nitrogen gas) for a minimum of 7 days and a maximum of 21 days in a double-blind study done at 36 centres in nine countries in the European Union. Care providers and investigators were masked to the computer-generated treatment assignment. The primary outcome was survival without development of bronchopulmonary dysplasia at postmenstrual age 36 weeks. Analysis was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00551642. FINDINGS: 399 infants were assigned to inhaled nitric oxide, and 401 to placebo. 395 and 400, respectively, were analysed. Treatment with inhaled nitric oxide and placebo did not result in significant differences in survival of infants without development of bronchopulmonary dysplasia (258 [65%] of 395 vs 262 [66%] of 400, respectively; relative risk 1.05, 95% CI 0.78-1.43); in survival at 36 weeks' postmenstrual age (343 [86%) of 399 vs 359 [90%] of 401, respectively; 0.74, 0.48-1.15); and in development of bronchopulmonary dysplasia (81 [24%] of 339 vs 96 [27%] of 358, respectively; 0.83, 0.58-1.17). INTERPRETATION: Early use of low-dose inhaled nitric oxide in very premature babies did not improve survival without bronchopulmonary dysplasia or brain injury, suggesting that such a preventive treatment strategy is unsuccessful. FUNDING: INO Therapeutics.


Assuntos
Displasia Broncopulmonar/epidemiologia , Displasia Broncopulmonar/prevenção & controle , Depuradores de Radicais Livres/administração & dosagem , Recém-Nascido Prematuro , Óxido Nítrico/administração & dosagem , Administração por Inalação , Displasia Broncopulmonar/complicações , Displasia Broncopulmonar/etnologia , Pressão Positiva Contínua nas Vias Aéreas , Método Duplo-Cego , Esquema de Medicação , União Europeia/estatística & dados numéricos , Feminino , Idade Gestacional , Humanos , Hipóxia Encefálica/etiologia , Hipóxia Encefálica/prevenção & controle , Incidência , Recém-Nascido , Masculino , Análise de Sobrevida , Resultado do Tratamento
20.
Acta Paediatr ; 99(6): 854-60, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20219040

RESUMO

AIMS: The aim of this study was to present data relating to the use of inhaled nitric oxide (iNO) in newborn infants included in the European Inhaled Nitric Oxide Registry. METHODS: Demographic, clinical and therapeutic data from seven European centres are reported. Univariate analyses were performed to identify factors associated with acute response to iNO and survival without extra corporeal membrane oxygenation (ECMO). RESULTS: A total of 112 newborn infants received iNO, with 40% being less than 34 weeks gestational age. The commonest indication for iNO was secondary pulmonary hypertension. Acute response to iNO was more common in infants with a higher oxygenation index (median OI 32.7 vs 22.6, p = 0.040), although acute response did not predict survival without ECMO. Infants who survived without ECMO had a lower OI prior to therapy (median OI 24 vs 43, p = 0.009), were commenced on a higher starting dose (median dose 20 ppm vs 10 ppm p = 0.013) and received a lower maintenance dose (median dose 10 vs 17 ppm, p = 0.027) than those who died or received ECMO. CONCLUSION: Collating and reporting data about iNO therapy in neonates across a number of European centres using a web-based system is feasible. These data may be used to monitor the clinical use of iNO, identify adverse effects, generate research hypotheses and promote high standards in the clinical use of iNO.


Assuntos
Doenças do Prematuro/terapia , Óxido Nítrico/administração & dosagem , Síndrome da Persistência do Padrão de Circulação Fetal/terapia , Administração por Inalação , Análise de Variância , Europa (Continente) , Oxigenação por Membrana Extracorpórea , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Projetos Piloto , Sistema de Registros , Resultado do Tratamento