Biochem Med (Zagreb) ; 30(1): 010502, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-31839720

RESUMO

Extravascular body fluids (EBF) analysis can provide useful information in the differential diagnosis of conditions that caused their accumulation. Their unique nature and particular requirements accompanying EBF analysis need to be recognized in order to minimize possible negative implications on patient safety. This recommendation was prepared by the members of the Working group for extravascular body fluid samples (WG EBFS). It is designed to address the total testing process and clinical significance of tests used in EBF analysis. The recommendation begins with a chapter addressing validation of methods used in EBF analysis, and continues with specific recommendations for serous fluids analysis. It is organized in sections referring to the preanalytical, analytical and postanalytical phase with specific recommendations presented in boxes. Its main goal is to assist in the attainment of national harmonization of serous fluid analysis and ultimately improve patient safety and healthcare outcomes. This recommendation is intended to all laboratory professionals performing EBF analysis and healthcare professionals involved in EBF collection and processing. Cytological and microbiological evaluations of EBF are beyond the scope of this document.


Assuntos
Líquidos Corporais/química , Técnicas de Laboratório Clínico/normas , Líquidos Corporais/metabolismo , Exsudatos e Transudatos/química , Exsudatos e Transudatos/metabolismo , Guias como Assunto , Humanos , Segurança do Paciente , Derrame Pleural/diagnóstico , Garantia da Qualidade dos Cuidados de Saúde , Sociedades Médicas , Manejo de Espécimes/normas
3.
Clin Chem Lab Med ; 57(12): 1882-1887, 2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31343976

RESUMO

Background Serum samples should be centrifuged for at least 10 min at 1300-2500 × g. Changed centrifugation conditions could compromise sample quality. The objective of this study was to compare the serum quality and turnaround time (TAT) using different centrifugation conditions. Methods The study was done in four different periods (A, B, C and D) at different conditions: for 10, 5 and 7 (A, B and C, respectively) at 2876 × g, and 7 (D) min at 4141 × g. Sample quality was assessed as the proportion of samples with: (a) aspiration errors, (b) H index >0.5 g/L and (c) suppressed reports of potassium (K) due to hemolysis. TAT was calculated for emergency samples. The proportions of samples (a), (b) and (c) were compared according to period A. Results The number of aspiration errors was significantly higher in samples centrifuged at 2876 × g for 5 min (p = 0.021) and remained unchanged when centrifuged for 7 min (p = 0.066 and 0.177, for periods C and D, respectively). In periods B, C and D, the proportion of samples with hemolysis was higher than that in period A (p-values 0.039, 0.009 and 0.042, respectively). TAT differed between all periods (p < 0.001), with the lowest TAT observed for B and D. The lowest number of samples exceeding 60-min TAT was observed in period D (p = 0.011). Conclusions The integrity of serum samples is changed with different centrifugation conditions than those recommended. Our study showed that shorter centrifugation at higher force (7 min at 4141 × g) significantly decreases TAT, with unchanged proportion of samples with aspiration errors.

4.
Biochem Med (Zagreb) ; 28(3): 031001, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30429683

RESUMO

The presence of cold agglutinins (CAs) in samples intended for complete blood count (CBC) using automated haematology analysers might cause serious preanalytical errors. In this report we describe the case of a 90-year old female patient admitted to the Emergency department following trauma injuries. A blood testing on admission revealed surprisingly low red blood cell count (0.99 x 1012/L), low haematocrit (0.102 L/L) which did not correlate with haemoglobin concentration (100 g/L), and high erythrocytes indices (mean corpuscular haemoglobin, 101 pg; mean corpuscular haemoglobin concentration, 980 g/L). In the second sample, after repeated collection, almost equal results were observed. Blood smear examination under the microscope revealed clusters of erythrocytes. Cold agglutinins presence was suspected and, in order to get valid results, sample was warmed to 37 °C. Correction of CBC was observed. Furthermore, we performed some additional analysis to confirm the presence of CAs in this patient. The aim of this report was to present the laboratory findings in a case of CAs and propose a laboratory procedure for whole blood samples with suspected CAs.


Assuntos
Artefatos , Contagem de Eritrócitos/métodos , Eritrócitos/citologia , Eritrócitos/efeitos dos fármacos , Ferimentos e Lesões/sangue , Idoso de 80 Anos ou mais , Crioglobulinas/farmacologia , Feminino , Humanos
5.
Clin Chem Lab Med ; 56(2): 236-241, 2018 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-28746044

RESUMO

BACKGROUND: The aim of our study was to determine the difference between glucose concentration measured 30 min after venipuncture in ice-chilled heparin plasma sample and all currently available citrate buffer-containing tubes (Greiner Glucomedics, Greiner FC Mix and Sarstedt GlucoEXACT) and still widely used sodium fluoride/potassium oxalate (NaF/Kox) tubes from Greiner. METHODS: Blood was collected from 20 healthy volunteers and 20 patients with diabetes into LiH, NaF/KOx, Glucomedics, FC mix and GlucoEXACT tubes. Glucose was measured within 30 min from blood sampling in duplicate on the Architect c8000 analyzer. Mean biases between all tube types were calculated and compared to the recommended criteria (1.95%). Additionally, glucose concentrations measured in all five tube types were compared using the Friedman test. RESULTS: In the entire studied population, glucose concentrations measured in Glucomedics, FC mix and GlucoEXACT were higher (7.3%, 3.2% and 2.0%, respectively) than in the ice-chilled LiH tubes. When all glycolysis inhibitor-containing tubes were compared, Glucomedics tubes significantly differed from GlucoEXACT and FC mix tubes (biases -4.9% and 4.0%, respectively). In addition, there was a significant difference between the NaF/KOx tube and Glucomedics, as well as FC mix tubes (biases 7.1% and 3.0%, respectively). CONCLUSIONS: Glucose concentrations measured in recommended ice-chilled lithium heparin- and citrate buffer-containing tubes are not comparable. Significant biases exist between various glycolysis inhibitor-containing tubes; therefore, they cannot be used interchangeably.


Assuntos
Glicemia/análise , Coleta de Amostras Sanguíneas/normas , Glicólise/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Viés , Coleta de Amostras Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/métodos , Tampões (Química) , Citratos/química , Heparina/química , Humanos , Pessoa de Meia-Idade
6.
Biomarkers ; 21(8): 692-698, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27121533

RESUMO

CONTEXT: Increased oxidative burden is found in chronic obstructive pulmonary disease (COPD). OBJECTIVE: To assess the association of ceruloplasmin, albumin, bilirubin, transferrin, thiols and malondialdehyde (MDA) with stable COPD. MATERIALS AND METHODS: Oxidative stress markers measured in 106 COPD patients and 45 healthy subjects were evaluated. RESULTS: Higher ceruloplasmin and MDA, and lower albumin, transferrin and thiols in COPD patients were found. Ceruloplasmin was the strongest single predictor of COPD. The model combining ceruloplasmin, albumin and thiols improved their individual diagnostic performances. CONCLUSIONS: Diagnostic characteristics of ceruloplasmin, albumin, transferrin, thiols and MDA suggest their potential value as additional tools in disease diagnosis.