Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Heart ; 105(20): 1559-1567, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31142594

RESUMO

OBJECTIVE: Patients with suspected acute myocardial infarction (AMI) in the setting of left bundle branch block (LBBB) present an important diagnostic and therapeutic challenge to the clinician. METHODS: We prospectively evaluated the incidence of AMI and diagnostic performance of specific ECG and high-sensitivity cardiac troponin (hs-cTn) criteria in patients presenting with chest discomfort to 26 emergency departments in three international, prospective, diagnostic studies. The final diagnosis of AMI was centrally adjudicated by two independent cardiologists according to the universal definition of myocardial infarction. RESULTS: Among 8830 patients, LBBB was present in 247 (2.8%). AMI was the final diagnosis in 30% of patients with LBBB, with similar incidence in those with known LBBB versus those with presumably new LBBB (29% vs 35%, p=0.42). ECG criteria had low sensitivity (1%-12%) but high specificity (95%-100%) for AMI. The diagnostic accuracy as quantified by the receiver operating characteristics (ROC) curve of hs-cTnT and hs-cTnI concentrations at presentation (area under the ROC curve (AUC) 0.91, 95% CI 0.85 to 0.96 and AUC 0.89, 95% CI 0.83 to 0.95), as well as that of their 0/1-hour and 0/2-hour changes, was very high. A diagnostic algorithm combining ECG criteria with hs-cTnT/I concentrations and their absolute changes at 1 hour or 2 hours derived in cohort 1 (45 of 45(100%) patients with AMI correctly identified) showed high efficacy and accuracy when externally validated in cohorts 2 and 3 (28 of 29 patients, 97%). CONCLUSION: Most patients presenting with suspected AMI and LBBB will be found to have diagnoses other than AMI. Combining ECG criteria with hs-cTnT/I testing at 0/1 hour or 0/2 hours allows early and accurate diagnosis of AMI in LBBB. TRIAL REGISTRATION NUMBER: APACE: NCT00470587; ADAPT: ACTRN12611001069943; TRAPID-AMI: RD001107;Results.

2.
Heart ; 105(18): 1423-1431, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31018955

RESUMO

OBJECTIVE: Assess the relative incidence and compare characteristics and outcome of unstable angina (UA) and non-ST-elevation myocardial infarction (NSTEMI). DESIGN: Two independent prospective multicentre diagnostic studies (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE] and High-Sensitivity Troponin in the Evaluation of Patients With Acute Coronary Syndrome [High-STEACS]) enrolling patients with acute chest discomfort presenting to the emergency department. Central adjudication of the final diagnosis was done by two independent cardiologists using all clinical information including serial measurements of high-sensitivity cardiac troponin (hs-cTn). All-cause death and future non-fatal MI were assessed at 30 days and 1 year. RESULTS: 8992 patients were enrolled at 11 centres. UA was adjudicated in 8.9%(95% CI 8.0 to 9.7) and 2.8% (95% CI 2.3 to 3.3) patients in APACE and High-STEACS, respectively, and NSTEMI in 15.1% (95% CI 14.0 to 16.2) and 13.4% (95% CI 12.4 to 14.3). Coronary artery disease was pre-existing in 73% and 76% of patients with UA. At 30 days, all-cause mortality in UA was substantially lower as compared with NSTEMI (0.5% vs 3.7%, p=0.002 in APACE, 0.7% vs 7.4%, p=0.004 in High-STEACS). Similarly, at 1 year in UA all-cause mortality was 3.3% (95% CI 1.2 to 5.3) vs 10.4% (95% CI 7.9 to 12.9) in APACE, and 5.1% (95% CI 0.7 to 9.5) vs 22.9% (95% CI 19.3 to 26.4) in High-STEACS, and similar to non-cardiac chest pain (NCCP). In contrast, future non-fatal MI in APACE was comparable in UA and NSTEMI (11.2%, 95% CI 7.8 to 14.6 and 7.9%, 95% CI 5.7 to 10.2), and higher than in NCCP (0.6%, 95% CI 0.2 to 1.0). CONCLUSIONS: The relative incidence and mortality of UA is substantially lower than that of NSTEMI, while the rate of future non-fatal MI is similar.

4.
Circulation ; 2019 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-30798615

RESUMO

BACKGROUND: The utility of B-type Natriuretic Peptide (BNP), N-terminal proBNP (NT-proBNP), and high-sensitivity cardiac troponin (hs-cTn) concentrations for diagnosis and risk-stratification of syncope is incompletely understood. METHODS: We evaluated the diagnostic and prognostic accuracy of BNP, NT-proBNP, hs-cTnT, and hs-cTnI concentrations, alone and against the ones of clinical assessments, in patients >45years presenting with syncope to the emergency department (ED) in a prospective diagnostic multicenter study. BNP, NT-proBNP, hs-cTnT and hs-cTnI concentrations were measured in a blinded fashion. Cardiac syncope, as adjudicated by two physicians based on all information available including cardiac work-up and 1-year follow-up, was the diagnostic endpoint. The EGSYS, a syncope-specific diagnostic score, served as the diagnostic comparator. Death and MACE at 30 and 720 days were the prognostic endpoints. MACE were defined as death, cardiopulmonary resuscitation, life-threatening arrhythmia, implantation of pacemaker/implantable cardioverter defibrillator, acute myocardial infarction, pulmonary embolism, stroke/transient ischemic attack, intracranial bleeding or valvular surgery. The ROSE, OESIL, San Fransisco Syncope Rule (SFSR) and Canadian Syncope Risk Score (CSRS) served as the prognostic comparators. RESULTS: Among 1538 patients eligible for diagnostic assessment, cardiac syncope was the adjudicated diagnosis in 234 patients (15.2%). BNP, NT-proBNP, hs-cTnT, and hs-cTnI were significantly higher in cardiac syncope vs. other causes (p<0.01). The diagnostic accuracy for cardiac syncope, as quantified by the area under the curve (AUC), was 0.77-0.78 (95% confidence interval (CI) 0.74-0.81) for all four biomarkers, and superior to the one of EGSYS (AUC 0.68 [95%-CI 0.65-0.71], p<0.001). Combining BNP/NT-proBNP with hs-cTnT/hs-cTnI further improved diagnostic accuracy to an AUC of 0.81 (p<0.01). BNP, NT-proBNP, hs-cTnT, and hs-cTnI cut-offs, achieving pre-defined thresholds for sensitivity and specificity (95%), allowed for rule-in or rule-out of ~30% of all patients. A total of 450 MACE occurred during follow-up. The prognostic accuracy of BNP, NT-proBNP, hs-cTnI, and hs-cTnT for MACE was moderate-to-good (AUC 0.75-0.79), superior to ROSE, OESIL and SFSR, and inferior to the CSRS. CONCLUSIONS: BNP, NT-proBNP, hs-cTnT, and hs-cTnI concentrations provide useful diagnostic and prognostic information in ED patients with syncope. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov Unique Identifier: NCT01548352.

5.
Clin Chem ; 65(3): 437-450, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30626633

RESUMO

BACKGROUND: We desired to determine cardiac troponin (cTn) concentrations necessary to achieve a positive predictive value (PPV) of ≥75% for acute myocardial infarction (AMI) to justify immediate admission of patients to a monitored unit and, in general, early coronary angiography. METHODS: In a prospective multicenter diagnostic study enrolling patients presenting to the emergency department with symptoms suggestive of AMI, final diagnoses were adjudicated by 2 independent cardiologists based on clinical information including cardiac imaging. cTn concentrations were measured using 5 different sensitive and high-sensitivity cTn (hs-cTn) assays in a blinded fashion at presentation and serially thereafter. The diagnostic end point was PPV for rule-in of AMI of initial cTn concentrations alone and in combination with early changes. RESULTS: Among 3828 patients, 616 (16%) had an AMI. At presentation, 7% to 14% of patients had cTnT/I concentrations associated with a PPV of ≥75%. Adding absolute or relative changes did not significantly further increase the PPV. PPVs increased from 46.5% (95% CI, 43.6-49.4) for hs-cTnT at presentation >14 ng/L to 78.9% (95% CI, 74.7-82.5) for >52 ng/L (P < 0.001), whereas PPVs in higher hs-cTnT strata remained largely unchanged [e.g., 82.4% (95% CI, 77.5-86.7) for >80 ng/L vs 83.9% (95% CI, 76.0-90.1) for >200 ng/L (P = 0.72)]. The addition of early changes in hs-cTnT further increased the PPV up to 60 ng/L, but not for higher concentrations. CONCLUSIONS: Serial sampling does not seem necessary for predicting AMI and concurrent decision-making in about 10% of patients, as it only marginally increases the PPV for AMI and not in a statistically or clinically significant way. CLINICALTRIALSGOV IDENTIFIER: NCT00470587.

6.
Int J Cardiol ; 283: 41-47, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30545622

RESUMO

BACKGROUND: The clinical availability of high-sensitivity cardiac troponin (hs-cTn) has enabled the development of several innovative strategies for the rapid rule-out of acute myocardial infarction (AMI). Due to the lack of direct comparisons, selection of the best strategy for clinical practice is challenging. METHODS: In a prospective international multicenter diagnostic study enrolling 3696 patients presenting with suspected AMI to the emergency department, we compared the safety and efficacy of 14 different hs-cTn-based strategies: hs-cTn concentrations below the limit of detection (LoD), dual-marker combining hs-cTn with copeptin, ESC 0 h/1 h-algorithm, 0 h/2 h-algorithm, 2 h-ADP-algorithm, NICE-algorithm, and ESC 0 h/3 h-algorithm, each using either hs-cTnT or hs-cTnI. The final diagnosis of AMI was adjudicated by two independent cardiologists using all available clinical information including cardiac imaging and serial hs-cTn concentrations. RESULTS: AMI was the final diagnosis in 16% of patients. Using hs-cTnT, safety quantified by the negative predictive value (NPV) and sensitivity was very high (99.8-100% and 99.5-100%) and comparable for all strategies, except the dual-marker approach (NPV 98.7%, sensitivity 96.7%). Similarly, using hs-cTnI, safety quantified by the NPV and sensitivity was very high (99.7-100% and 98.9-100%) and comparable for all strategies, except the dual-marker approach (NPV 96.9%, sensitivity 90.4%) and the NICE-algorithm (NPV 99.1%, sensitivity 94.7%). Efficacy, quantified by the percentage of patients eligible for rule-out, differed markedly, and was lowest for LoD-algorithm (15.7-26.8%). CONCLUSION: All rapid rule-out algorithms, except the dual-marker strategy and the NICE-algorithm using hs-cTnI, favorably combine safety and efficacy, and can be considered for routine clinical practice. CLINICAL TRIAL REGISTRATION: NCT00470587, http://clinicaltrials.gov/show/NCT00470587.

8.
Dis Markers ; 2018: 9136971, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30538785

RESUMO

Background: Clinical short-term risk stratification is a recommended approach in patients with chest pain and possible acute myocardial infarction (AMI) to further improve high safety of biomarker-based rule-out algorithms. The study aim was to assess clinical performance of baseline concentrations of high-sensitivity cardiac troponin T (hs-TnT) and copeptin and the modified HEART score (mHS) in early presenters to the emergency department with chest pain. Methods: This cohort study included patients with chest pain with onset maximum of 6 h before admission and no persistent ST-segment elevation on electrocardiogram. hs-TnT, copeptin, and the mHS were assessed from admission data. The diagnostic and prognostic value for three baseline rule-out algorithms: (1) single hs-TnT < 14 ng/l, (2) hs-TnT < 14 ng/l/mHS ≤ 3, and (3) hs-TnT < 14 ng/l/mHS ≤ 3/copeptin < 17.4 pmol/l, was assessed with sensitivity and negative predictive value. Primary diagnostic endpoint was the diagnosis of AMI. Prognostic endpoint was death and/or AMI within 30 days. Results: Among 154 enrolled patients, 44 (29%) were classified as low-risk according to the mHS; AMI was diagnosed in 105 patients (68%). For ruling out AMI, the highest sensitivity and NPV from all studied algorithms were observed for hs-TnT/mHS/copeptin (100%, 95% CI 96.6-100, and 100%, 95% CI 75.3-100). At 30 days, the highest event-free survival was achieved in patients stratified with hs-TnT/mHS/copeptin algorithm (100%) with 100% (95% CI 75.3-100) NPV and 100% (95% CI 96.6-100) sensitivity. Conclusions: The combination of baseline hs-TnT, copeptin, and the mHS has an excellent sensitivity and NPV for short-term risk stratification. Such approach might improve the triage system in emergency departments and be a bridge for inclusion to serial blood sampling algorithms.


Assuntos
Dor no Peito/fisiopatologia , Glicopeptídeos/sangue , Infarto do Miocárdio/diagnóstico , Troponina T/sangue , Idoso , Algoritmos , Biomarcadores/sangue , Dor no Peito/sangue , Dor no Peito/etiologia , Dor no Peito/mortalidade , Estudos de Coortes , Estudos Transversais , Eletrocardiografia , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos
9.
Int J Cardiol ; 269: 114-121, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30224031

RESUMO

BACKGROUND: Various scores have been derived for the assessment of syncope patients in the emergency department (ED) but stay inconsistently validated. We aim to compare their performance to the one of a common, easy-to-use CHADS2 score. METHODS: We prospectively enrolled patients ≥ 40 years old presenting with syncope to the ED in a multicenter study. Early clinical judgment (ECJ) of the treating ED-physician regarding the probability of cardiac syncope was quantified. Two independent physicians adjudicated the final diagnosis after 1-year follow-up. Major cardiovascular events (MACE) and death were recorded during 2 years of follow-up. Nine scores were compared by their area under the receiver-operator characteristics curve (AUC) for death, MACE or the diagnosis of cardiac syncope. RESULTS: 1490 patients were available for score validation. The CHADS2-score presented a higher or equally high accuracy for death in the long- and short-term follow-up than other syncope-specific risk scores. This score also performed well for the prediction of MACE in the long- and short-term evaluation and stratified patients with accuracy comparative to OESIL, one of the best performing syncope-specific risk score. All scores performed poorly for diagnosing cardiac syncope when compared to the ECJ. CONCLUSIONS: The CHADS2-score performed comparably to more complicated syncope-specific risk scores in the prediction of death and MACE in ED syncope patients. While better tools incorporating biochemical and electrocardiographic markers are needed, this study suggests that the CHADS2-score is currently a good option to stratify risk in syncope patients in the ED. TRIAL REGISTRATION: NCT01548352.

10.
Eur Heart J ; 39(42): 3780-3794, 2018 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-30169752

RESUMO

Aims: We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results: We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.5-99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767). Conclusion: While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).

11.
J Am Coll Cardiol ; 72(6): 620-632, 2018 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-30071991

RESUMO

BACKGROUND: The safety of the European Society of Cardiology (ESC) 0/1-h algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction (NSTEMI) using high-sensitivity cardiac troponin (hs-cTn) has been questioned. OBJECTIVES: This study aimed to validate the diagnostic performance of the 0/1-h algorithm in a large multicenter study. METHODS: The authors prospectively enrolled unselected patients in 6 countries presenting to the emergency department with symptoms suggestive of NSTEMI. Final diagnosis was centrally adjudicated by 2 independent cardiologists. Hs-cTnT and hs-cTnI blood concentrations were measured at presentation and after 1 h. Safety of rule-out was quantified by the negative predictive value (NPV) for NSTEMI, accuracy of rule-in by the positive predictive value (PPV), and overall efficacy by the proportion of patients triaged towards rule-out or rule-in within 1 h. RESULTS: Prevalence of NSTEMI was 17%. Among 4,368 patients with serial hs-cTnT measurements available, safety of rule-out (NPV 99.8%, 2,488 of 2,493), accuracy of rule-in (PPV 74.5%, 572 of 768), and overall efficacy were high by assigning three-fourths of patients either to rule-out (57%, 2,493 to 4,368) or rule-in (18%, 768 to 4,368). Similarly, among 3,500 patients with serial hs-cTnI measurements, safety of rule-out (NPV 99.7%, 1,528 of 1,533), accuracy of rule-in (PPV 62.3%, 498 of 800), and overall efficacy were high by assigning more than two-thirds of patients either to rule-out (44%, 1,533 of 3,500) or rule-in (23%, 800 of 3,500). Excellent safety was confirmed in multiple subgroup analyses including patients presenting early (≤3 h) after chest pain onset. CONCLUSIONS: The ESC 0/1-h algorithm using hs-cTnT and hs-cTnI is very safe and effective in triaging patients with suspected NSTEMI. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587; and Biomarkers in Acute Cardiac Care [BACC]; NCT02355457).

12.
Clin Chem ; 64(9): 1347-1360, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29941469

RESUMO

BACKGROUND: Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h and 0/2-h algorithms. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms. RESULTS: AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92-0.96) and comparable with 0.95 (95% CI, 0.93-0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90-0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3-100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8-95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1-100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1-97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication. CONCLUSIONS: Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587.

14.
Circulation ; 138(10): 989-999, 2018 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-29691270

RESUMO

BACKGROUND: Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction. METHODS: The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms. RESULTS: Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34% to 41% in the original (sum: negative predictive value [NPV] 100% [95% confidence interval (CI), 99.5% to 100%]; product: NPV 100% [95% CI, 99.5% to 100%]) and in the validation cohort (sum: NPV 99.6% [95% CI, 99.0-99.9%]; product: NPV 99.4% [95% CI, 98.8-99.8%]). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule-out (40% to 43% ruled out; NPV original cohort 99.9% [95% CI, 99.2-100%]; NPV validation cohort 99.5% [95% CI, 98.9-99.8%]) and rule-in (positive predictive value [PPV] original cohort 74.4% [95% Cl, 69.6-78.8%]; PPV validation cohort 84.0% [95% Cl, 79.7-87.6%]). CONCLUSIONS: New strategies combining hs-cTnI and hs-cTnT concentrations may significantly increase the number of patients eligible for very early and safe rule-out, but do not seem helpful for the rule-in of acute myocardial infarction. CLINICAL TRIAL REGISTRATION: URL (APACE): https://www.clinicaltrial.gov . Unique identifier: NCT00470587. URL (ADAPT): www.anzctr.org.au . Unique identifier: ACTRN12611001069943.

15.
Dis Markers ; 2018: 6597387, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29619130

RESUMO

Background: In patients admitted with chest pain and suspected acute coronary syndrome (ACS), it is crucial to early identify those who are at higher risk of adverse events. The study aim was to assess the predictive value of copeptin in patients admitted to the emergency department with chest pain and nonconclusive ECG. Methods: Consecutive patients suspected for an ACS were enrolled prospectively. Copeptin and high-sensitive troponin T (hs-TnT) were measured at admission. Patients were followed up at six and 12 months for the occurrence of death and major adverse cardiac and cerebrovascular events (MACCE). Results: Among 154 patients, 11 patients died and 26 experienced MACCE. Mortality was higher in copeptin-positive than copeptin-negative patients with no difference in the rate of MACCE. Copeptin reached the AUC 0.86 (0.75-0.97) for prognosis of mortality at six and 0.77 (0.65-0.88) at 12 months. It was higher than for hs-TnT and their combination at both time points. Copeptin was a strong predictor of mortality in the Cox analysis (HR14.1 at six and HR4.3 at 12 months). Conclusions: Copeptin appears to be an independent predictor of long-term mortality in a selected population of patients suspected for an ACS. The study registration number is ISRCTN14112941.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Biomarcadores/metabolismo , Dor no Peito/metabolismo , Glicopeptídeos/metabolismo , Regulação para Cima , Síndrome Coronariana Aguda/metabolismo , Síndrome Coronariana Aguda/mortalidade , Idoso , Área Sob a Curva , Dor no Peito/etiologia , Dor no Peito/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos
16.
Cardiol J ; 25(5): 601-610, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29611166

RESUMO

BACKGROUND: While prolongation of QRS duration and QTc interval during acute myocardial infarction (AMI) has been reported in animals, limited data is available for these readily available electrocardiography (ECG) markers in humans. METHODS: Diagnostic and prognostic value of QRS duration and QTc interval in patients with suspected AMI in a prospective diagnostic multicentre study were prospectively assessed. Digital 12-lead ECGs were recorded at presentation. QRS duration and QTc interval were automatically calculated in a blinded fashion. Final diagnosis was adjudicated by two independent cardiologists. The prognostic endpoint was all-cause mortality during 24 months of follow-up. RESULTS: Among 4042 patients, AMI was the final diagnosis in 19% of patients. Median QRS duration and median QTc interval were significantly greater in patients with AMI compared to those with other final diagnoses (98 ms [IQR 88-108] vs. 94 ms [IQR 86-102] and 436 ms [IQR 414-462] vs. 425 ms [IQR 407-445], p < 0.001 for both comparisons). The diagnostic value of both ECG signatures however was only modest (AUC 0.56 and 0.60). Cumulative mortality rates after 2 years were 15.9% vs. 5.6% in patients with a QRS > 120 ms compared to a QRS duration ≤ 120 ms (p < 0.001), and 11.4% vs. 4.3% in patients with a QTc > 440 ms compared to a QRS duration ≤ 440 ms (p < 0.001). After adjustment for age and important ECG and clinical parameters, the QTc interval but not QRS duration remained an independent predictor of mortality. CONCLUSIONS: Prolongation of QRS duration > 120 ms and QTc interval > 440 ms predict mortality in patients with suspected AMI, but do not add diagnostic value.

17.
Dis Markers ; 2018: 5287573, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29599854

RESUMO

25-hydroxyvitamin D (25(OH)D) plays a crucial role in human homeostasis. Its deficiency (vitamin D deficiency-VDD), being common in European population, combined with elevated concentration of parathyroid hormone (PTH), represents a vicious cycle of mechanisms leading to heart failure (HF). Despite several papers published in that field, the effect of VDD and PTH concentration on cardiovascular system remains unequivocal; thus, the aim of the study was to compare these data among HF and non-HF patients being prospectively enrolled into the study during hospital stay in the cardiology ward. Patients with HF had higher PTH concentration (85.0 ± 52.6 versus 64.5 ± 31.7, p ≤ 0.02) compared to non-HF patients. Mean PTH values were associated with the clinical status expressed by the New York Heart Association class (NYHA class) ("0"-66.04, "I"-56.57, "II"-72.30, "III"-85.59, and "IV"-144.37 pg/ml, p ≤ 0.00004). Interestingly, neither 25(OH)D (31.5 versus 29.7 ng/ml, p ≤ ns) nor phosphorus (P) (1.23 versus 1.18 mmol/l, p ≤ ns) nor total calcium (Ca2+) concentration (2.33 versus 2.37 mmol/l, p ≤ ns) differed among the groups. Reassuming PTH serum concentration in contrary to 25(OH)D, P and Ca2+ are significantly raised among the patients with HF and shows significant relationship with the clinical status expressed by the NYHA class.


Assuntos
Fibrilação Atrial/sangue , Dislipidemias/sangue , Insuficiência Cardíaca/sangue , Hipertensão/sangue , Hormônio Paratireóideo/sangue , Deficiência de Vitamina D/sangue , Vitamina D/análogos & derivados , Idoso , Fibrilação Atrial/diagnóstico , Biomarcadores/sangue , Cálcio/sangue , Estudos Transversais , Dislipidemias/diagnóstico , Feminino , Insuficiência Cardíaca/diagnóstico , Hospitalização , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Fósforo/sangue , Vitamina D/sangue , Deficiência de Vitamina D/diagnóstico
18.
Clin Chem ; 64(3): 515-525, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29343534

RESUMO

BACKGROUND: There is concern that high-sensitivity cardiac troponin (hs-cTn) may have low diagnostic accuracy in patients with low acute coronary syndrome (ACS) probability. METHODS: We prospectively stratified patients presenting with acute chest discomfort to the emergency department (ED) into 3 groups according to their probability for ACS as assessed by the treating ED physician using a visual analog scale: ≤10%, 11% to 79%, and ≥80%, reviewing all information available at 90 min. hs-cTnT and hs-cTnI concentrations were determined in a blinded fashion. Two independent cardiologists adjudicated the final diagnosis. RESULTS: Among 3828 patients eligible for analysis, 1189 patients had low (≤10%) probability for ACS. The incidence of non-ST-segment elevation myocardial infarction (NSTEMI) increased from 1.3% to 12.2% and 54.8% in patients with low, intermediate, and high ACS probability, respectively. The positive predictive value of hs-cTnT and hs-cTnI was low in patients with low ACS probability and increased with the incidence of NSTEMI, whereas the diagnostic accuracy of hs-cTnT and hs-cTnI for NSTEMI as quantified by the area under the curve (AUC) was very high and comparable among all 3 strata, e.g., AUC hs-cTnI, 0.96 (95% CI, 0.94-0.97); 0.87 (95% CI, 0.85-0.89); and 0.89 (95% CI, 0.87-0.92), respectively. Findings were validated using bootstrap analysis as an alternative methodology to define ACS probability. Similarly, higher hs-cTnT/I concentrations independently predicted all-cause mortality within 2 years (e.g., hs-cTnT hazard ratio, 1.39; 95% CI, 1.27-1.52), irrespective of ACS probability. CONCLUSIONS: Diagnostic and prognostic accuracy and utility of hs-cTnT and hs-cTnI remain high in patients with acute chest discomfort and low ACS probability.ClinicalTrials.gov Identifier: NCT00470587.

19.
Circulation ; 137(5): 436-451, 2018 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-29101287

RESUMO

BACKGROUND: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. METHODS: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m2, and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. RESULTS: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. CONCLUSIONS: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA