Herzschrittmacherther Elektrophysiol ; 31(1): 84-90, 2020 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-31758249

RESUMO

The rising number of catheter ablations of atrial fibrillation increases radiation exposure for both patients and surgeons. Fortunately, this trend is counteracted by the development of measures to reduce total fluoroscopy time using non-fluoroscopic catheter visualization. Since even low-dose radiation can cause serious injury, all options to reduce radiation burden must be utilized (ALARA, "as low as reasonably achievable"). Dose reduction protocols with low-dose settings, which include reduced framerates, pulse duration, detector entrance dose and increased beam hardening, play a decisive role in this regard. This review provides a state-of-the-art summary of non-fluoroscopic catheter visualization and dose reduction protocols for catheter ablation of atrial fibrillation.

2.
J Electrocardiol ; 56: 38-42, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31255952

RESUMO

BACKGROUND: Left atrial low voltage areas (LVA) are associated with increased recurrence rates of atrial fibrillation (AF) after catheter ablation and can be a potential ablation target during the procedure. Therefore, noninvasive prediction of the presence and the distribution of LVA may help physicians to predict ablation outcomes and to guide antiarrhythmic management. MATERIAL AND METHODS: Seventy-three consecutive patients with atrial fibrillation undergoing first time left atrial ablation for paroxysmal or persistent AF were enrolled. P-wave properties (amplitude and duration) were measured in all limb and precordial leads in pre-interventional sinus rhythm surface ECGs and correlated with total LVA size. LVA were detected via high density low voltage maps of the left atrium in sinus rhythm. LVA were then manually encircled, their total size was calculated and given as a percentage of the total LA surface area. RESULTS: A significant, inverse correlation with LVA size was shown for P-wave amplitude for leads I, II, aVR, aVF, V1, V4, V5 and V6. Additionally, a significant positive correlation between LVA size and P-wave duration was shown for leads V1, V2 and V3. As the strongest correlation was shown for the amplitude in lead I (R = -0.578), this lead was used to find a potential cutoff for LVA prediction. The best cut-off for a P-wave amplitude in lead I to predict severe scarring (defined as LVA size >35%, according to UTAH stadium IV) was 0.062 mV with an area-under-the receiver-operating-characteristic curve of 0.935, a sensitivity of 85% and a specificity of 88%. CONCLUSIONS: P-wave duration and amplitude show significant correlations with LVA size and may be used as a noninvasive tool to predict severe scarring. Amplitudes in lead I smaller than 0.062 mV were found to be predictive of LVA >35%.

3.
J Anxiety Disord ; 64: 16-23, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30875662

RESUMO

Patients with anxiety disorders have a lower heart rate variability (HRV) than healthy controls. Low HRV is associated with cardiovascular disease and dysfunction of the autonomic nervous system (ANS). The aim of the present study was to investigate if HRV in patients with agoraphobia with or without panic disorder can be influenced by cognitive behavioral therapy (CBT). 73 patients with agoraphobia with or without panic disorder were included in the study. Heart rate (HR) and HRV were recorded at rest before and after CBT and during in-vivo exposure. No changes in HR and HRV were observed throughout therapy. During in-vivo exposure HRV increased significantly and HR exhibited a tendency to decrease. Despite clinical improvement of anxiety symptoms, ANS activity at rest did not seem to be influenced by CBT. However, during in-vivo exposure, HRV changed significantly, indicating a higher parasympathetic activity at the end of exposure.

4.
Int J Cardiol ; 286: 56-60, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30773268

RESUMO

BACKGROUND: Electrographic-Flow-(EGF)-Mapping is a novel method to identify Atrial Fibrillation (AF) drivers. Sources of excitation during AF can be characterized and monitored. OBJECTIVE: The aim of this study was to evaluate the correlation between velocity of EGF around a respective AF source and its spatial variability (SV) and stability (SST). METHODS: 25 patients with AF were included in this study (persistent: n = 24, long-standing persistent: n = 1; mean age 70 ±â€¯8.3 years, male: n = 17). Focal impulse and Rotor-Mapping (FIRM) was performed in addition to pulmonary vein isolation. One-minute epochs of unipolar electrograms recorded via a 64-pole basket catheter in both atria were re-analyzed with EGF-Mapping. SST was calculated as the percentage of time in which a source was detected. RESULTS: AF sources identified with EGF-Mapping show a wide range of SV during 1 min covering between 0.12% and 38% of the recorded basket-catheter surface. The 12 atria where the sources showed highest temporal stability (TS; between 34% and 97% of 1 min recorded) and those 12 with the lowest TS (between 11 and 20%) differed significantly in their velocities (17.8 el/s vs 12.2 el/s; p < 0.01). In 11 atria ablation caused an average decrease of TS by 47% and of velocity by 27% while SV more than doubled. CONCLUSION: Less stable AF-sources with high spatial variability showed reduced excitation propagation velocity while stable AF sources displayed a high average velocity in their vicinity. Importantly, catheter ablation reduced stability of sources and velocity suggesting a role of these parameters in guidance of ablation. CONDENSED ABSTRACT: Electrographic Flow (EGF)-Mapping is a novel method to identify Atrial Fibrillation (AF) drivers based on modeling of an electrical potential surface and subsequent flow analysis. Sources of excitation during AF can be characterized and monitored. The aim of this study was to evaluate the correlation between velocity of EGF around a respective AF source and its spatial variability and stability. Less stable AF sources with high spatial variability showed reduced excitation propagation velocity while very stable AF sources displayed a high average velocity in their vicinity. Catheter ablation reduced stability of sources and velocity.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Período Pós-Operatório , Período Pré-Operatório , Fatores de Tempo , Resultado do Tratamento
5.
Clin Res Cardiol ; 108(5): 465-467, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30259106

RESUMO

Late perforation of the atrial wall after pacemaker implantation frequently remains asymptomatic but may cause chest pain, dyspnea or syncope. Perforation can also lead to rarer complications such as hemoptysis and pneumopericardium. We present the case of a patient who developed progressive hemoptysis 3 years after a dual-chamber pacemaker implantation. Pacemaker interrogation showed stable impedance of the right atrial lead and stable pacing threshold values. CT revealed perforation of the right atrial wall by the RA-lead with consecutive pneumopericardium and diffuse lung bleeding of the right middle lobe. The patient was hemodynamically stable at all times. The right atrial lead was transvenously extracted and replaced without any further complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Remoção de Dispositivo/métodos , Átrios do Coração/lesões , Traumatismos Cardíacos/complicações , Hemoptise/etiologia , Marca-Passo Artificial/efeitos adversos , Pneumopericárdio/etiologia , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/terapia , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/cirurgia , Hemoptise/diagnóstico , Humanos , Pneumopericárdio/diagnóstico , Fatores de Tempo , Tomografia Computadorizada por Raios X
7.
Clin Res Cardiol ; 107(11): 1021-1032, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29744616

RESUMO

BACKGROUND: The optimal ablation approach for the treatment of persistent atrial fibrillation (AF) is still under debate; however, the identification and elimination of AF sources is thought to play a key role. Currently available technologies for the identification of AF sources are not able to differentiate between active rotors or focal impulse (FI) and passive circular turbulences as generated by the interaction of a wave front with a functional obstacle such as fibrotic tissue. OBJECTIVES: This study introduces electrographic flow (EGF) mapping as a novel technology for the identification and characterization of AF sources in humans. METHODS: Twenty-five patients with AF (persistent: n = 24, long-standing persistent: n = 1; mean age 70.0 ± 8.3 years, male: n = 17) were included in this prospective study. Focal impulse and Rotor-Mapping (FIRM) was performed in addition to pulmonary vein isolation using radiofrequency in conjunction with a 3D-mapping-system. One-minute epochs were exported from the EP-recording-system and re-analyzed using EGF mapping after the procedure. RESULTS: 44 potential AF sources (43 rotors and one FI) were identified with FIRM and 39 of these rotors were targeted for ablation. EGF mapping verified 40 of these patterns and identified 24/40 (60%) as active sources while 16/40 (40%) were classified as passive circular turbulences. Four rotors were not identified by EGF mapping. CONCLUSION: EGF is the first method to identify active AF sources during AF ablation procedures in humans and discriminate them from passive rotational phenomena, which occur if the excitation wavefront passes conduction bariers. EGF mapping may allow improved guidance of AF ablation procedures.


Assuntos
Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
8.
Europace ; 20(5): 772-777, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29741689

RESUMO

Aims: The efficacy of the second-generation cryoballoon (CB) ablation in patients with atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in elderly patients is missing. The aim of this study was to evaluate the long-term success rate of pulmonary vein isolation (PVI) in patients ≥75 years vs. <75 years using the second-generation 28mm CB. Methods and results: Eighty patients [n = 40 ≥75 years (Group 1); n = 40 <75 years (Group 2)] with paroxysmal [n = 37 (46%) or persistent (n = 43 (54%)] AF were included. Median follow-up was 12 [6;18] months (Group 1 vs. 13 [6;27]) months (Group 2; P = 0.8). PVI was performed in all patients using cryoablation. Follow-up was obtained using 24h-Holter monitoring or via an implanted loop recorder or pacemaker. CHA2DS2VASc-Score (Group 1: 4 [4;5] vs. Group 2: 2 [1;3], P < 0.001) and HASBLED-Score (Group 1: 2 [2;3] and Group 2: 2 [1;3], (P = 0.009)) differed significantly between the two groups. Mean fluoroscopy time was 22.9 [16.3;31.9] in Group 1 and 24.5 [19.1;30.6] in Group 2 (P = 0.75), and mean procedure time was 125 min [105;151] in Group 1 and 130.5 min [117.5;147.3] in Group 2 (P = 0.66). Arrhythmia recurrence was similar in Group 1 and Group 2 (12/40 (30%) vs. 10/40 (25%) (P = 0.62). One transient ischaemic attack occurred in Group 2. No further major complications were documented in this patients cohort. Conclusion: CB ablation in patients ≥75 years has favourable success rates and similar complication rates compared with patients <75 years.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Efeitos Adversos de Longa Duração , Fatores Etários , Idoso , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Eletrocardiografia Ambulatorial/métodos , Feminino , Seguimentos , Humanos , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/etiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
9.
Int J Cardiol ; 248: 84-91, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28843718

RESUMO

BACKGROUND: Thus far, the topic hemostatic agent PerClot® is used for surgical procedures. Data about the use of PerClot® for cardiac-rhythm-devices (CRD) implantation are missing. The aim of this study was to evaluate the safety and efficacy of PerClot® in patients with high bleeding risk. METHODS AND RESULTS: In this prospective randomized study we planned to include 150 patients admitted for CRD-Implantation receiving anticoagulation and/or dual-antiplatelet-therapy. Participants were randomized to receive PerClot® versus standard-of-care. The primary endpoint was the incidence of pocket hematoma. Safety endpoint was pocket infection. After a planned safety-interim-analysis the study was terminated early because of safety concerns. 51 patients were included. The two groups were comparable with regard to age (73±11years vs. 74±10years; p=0.71), CHA2DS2VASc (3.6±1.5 vs. 4.0±1.5; p=0.27) and HASBLED-Score (2.4±1.1 vs. 2.5±1.0; p=0.98), CRD or procedure type, anticoagulant or anti-platelet therapy. The use of PerClot® resulted in a higher incidence of postoperative fever (7 (28%) vs. 0 (0%); p=0.004), higher C-Reactive Protein (66.1±50.5mg/l vs. 25.9±22.5mg/l; p=0.002); and higher postoperative white blood cell count (13.5±4.3/nl vs. 8.8±2.6/nl; p<0.001). Hematoma formation did not differ significantly (p=0.14). Reoperation was not necessary in any patient. CONCLUSION: This first randomized controlled study for the topical use of the hemostatic agent PerClot® in CRD implantation was terminated early by the safety monitoring board because of an augmented rate of fever and inflammatory markers in the PerClot® group. The addition of PerClot® does not suggest a benefit with regard to the frequency of pocket hematoma.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Terapia de Ressincronização Cardíaca/tendências , Hemostáticos/administração & dosagem , Marca-Passo Artificial/tendências , Polissacarídeos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos de Coortes , Feminino , Seguimentos , Hemorragia/diagnóstico , Hemorragia/etiologia , Hemorragia/prevenção & controle , Hemostáticos/normas , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Projetos Piloto , Polissacarídeos/normas , Estudos Prospectivos , Fatores de Risco , Método Simples-Cego , Resultado do Tratamento
10.
Clin Cardiol ; 40(11): 1095-1099, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28846806

RESUMO

BACKGROUND: Data are limited on the safety of periprocedural anticoagulation with novel oral anticoagulants (NOACs) in patients undergoing pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB) for the treatment of atrial fibrillation. HYPOTHESIS: We hypothesized that the incidence of acute periprocedural complications in patients undergoing PVI do not differ between patients treated with VKA compared to NOACs. METHODS: In 200 consecutive patients (mean age, 64.3 _ 10.6 years; female, n = 83) with symptomatic atrial fibrillation, PVI using the second-generation 28-mm CB was performed. In patients treated with NOACs, the medication was stopped the day of the procedure and continued the evening after the procedure with a reduced dosage. Patients treated with phenprocoumon were continued on uninterrupted phenprocoumon with a target INR of 2 to 3. If INR was <2, bridging with low-molecular-weight heparin was performed. RESULTS: Forty-seven of 200 patients (23.5%) were treated with a vitamin K antagonist (VKA) and 55 (27.5%) were treated with apixaban, 67 (33.5%) with rivaroxaban, and 31 (15.5%) with dabigatran. Seven (3.5%) major complications occurred in the overall population. Major bleeding complications did not differ significantly between the 2 groups (P = 0.23). One patient taking VKA had a pericardial tamponade at the end of the procedure; 2 patients treated with apixaban developed a groin hematoma requiring surgical intervention. Transient ischemic attack occurred in 1 patient of the apixaban and rivaroxaban group. CONCLUSIONS: Apixaban, rivaroxaban, and dabigatran, compared with uninterrupted VKA, did not show a higher risk for major bleeding or ischemic complications in patients undergoing PVI using the second-generation CB.


Assuntos
Antitrombinas/administração & dosagem , Fibrilação Atrial/terapia , Cateteres Cardíacos , Criocirurgia/instrumentação , Dabigatrana/administração & dosagem , Inibidores do Fator Xa/administração & dosagem , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Rivaroxabana/administração & dosagem , Administração Oral , Idoso , Antitrombinas/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Transtornos Cerebrovasculares/etiologia , Criocirurgia/efeitos adversos , Dabigatrana/efeitos adversos , Esquema de Medicação , Monitoramento de Medicamentos/métodos , Desenho de Equipamento , Inibidores do Fator Xa/efeitos adversos , Feminino , Heparina de Baixo Peso Molecular/administração & dosagem , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Femprocumona/administração & dosagem , Hemorragia Pós-Operatória/induzido quimicamente , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Rivaroxabana/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Vitamina K/antagonistas & inibidores
11.
Heart Rhythm ; 13(9): 1817-22, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27241353

RESUMO

BACKGROUND: The efficacy of the second-generation cryoballoon (CB) in patients with paroxysmal atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in patients with persistent AF are sparse. OBJECTIVE: The aim of this study was to evaluate the 2-year success rate of pulmonary vein isolation in patients with persistent AF using the second-generation CB. METHODS: Fifty consecutive patients (mean age 64.6 ± 9.9 years; 19 women [38%]) with persistent AF were included in this analysis. The mean follow-up period was 22 ± 11 months. All patients were ablated using the second-generation 28-mm CB. Isolation of the pulmonary veins was confirmed using a spiral mapping catheter. In all patients, follow-up was obtained using 24-hour Holter monitoring or via interrogation of an implanted loop recorder or pacemaker. RESULTS: The mean left atrial diameter was 43.6 ± 5.6 mm, the mean CHA2DS2-VASc score was 2.8 ± 1.5, and the mean HAS-BLED score was 2.1 ± 1.2. The mean fluoroscopy time was 25.8 ± 9 minutes, and the mean procedural time was 146.4 ± 37.8 minutes. After 22 ± 11 months, the frequency of arrhythmia recurrence was 22 of 50 (44%) in the overall group (paroxysmal AF 6 of 22 [27%]; persistent AF 16 of 22 [73%]). No major complications occurred. Aneurysma spurium not requiring surgical intervention occurred in 1 (2%) patient. No phrenic nerve palsy was observed. CONCLUSION: Two years' results after pulmonary vein isolation using the second-generation CB in patients with persistent AF are promising. The clinical success rate appears to be similar to the reported success rates of radiofrequency ablation for the treatment of persistent AF.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Falha de Tratamento , Resultado do Tratamento
12.
Herzschrittmacherther Elektrophysiol ; 27(2): 156-60, 2016 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-27193769

RESUMO

We report a 49-year-old patient who presented with tachycardia in our emergency room. The 12-lead ECG showed a wide complex tachycardia with a heart rate of 234 beats per minute. After structural heart disease was excluded via echocardiography, coronary angiography and magnetic resonance imaging, an electrophysiological study was performed. During programmed ventricular stimulation, a fascicular tachycardia was induced, which was successfully treated by radiofrequency ablation. Fascicular ventricular tachycardia is a rare tachycardia that occurs in patients without structural heart disease. Radiofrequency ablation can be performed safely and shows a high success rate. Differential diagnoses of fascicular ventricular tachycardias are substrate-based ventricular tachycardia and supraventricular tachycardia.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Técnicas de Imagem Cardíaca/métodos , Ablação por Cateter/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
J Arrhythm ; 32(2): 154-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27092199

RESUMO

We report the case of a 56-year-old female who presented with symptomatic paroxysmal atrial fibrillation. Anamnestic heparin-induced thrombocytopenia (HIT) type II was suspected, and a rapid diagnostic test showed antibodies against platelet factor 4. The heparin-induced platelet activation-assay was negative. Radiofrequency pulmonary vein isolation with intraprocedural anticoagulation using bivalirudin was ultimately performed. Dosing was controlled by monitoring the activated clotting time. Post-procedural blood tests were normal. There were no thromboembolic or bleeding events. Bivalirudin is a therapeutic option for anticoagulation during pulmonary vein isolation procedures in patients with a history of HIT type II.

14.
Wien Med Wochenschr ; 166(5-6): 188-91, 2016 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-26943921

RESUMO

We report three patients with an age above 90 years presented with symptomatic bradycardia and higher grade AV block in our clinic. The oldest patient was 100 years. All three patients could be supplied safely and without complications with a dual chamber pacemaker. Our case series shows that a dual chamber pacemaker implantation is safe and feasible in patients in very advanced age. A surgical management with local anesthetic (lidocaine), fentanyl and midazolam in individual cases is possible. This and a short hospital stay reduce the risk of delirium. It is a group of patients, which will increase in the future and requires more intensive care than the standard pacemaker patient.


Assuntos
Bloqueio Atrioventricular/terapia , Bradicardia/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Idoso Fragilizado , Idoso de 80 Anos ou mais , Anestesia Local , Bloqueio Atrioventricular/diagnóstico , Áustria , Bradicardia/diagnóstico , Comorbidade , Sedação Consciente , Delírio/prevenção & controle , Eletrocardiografia , Feminino , Humanos , Resultado do Tratamento
15.
Europace ; 18(2): 238-45, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25995399

RESUMO

AIMS: Atrial standstill is characterized by the absence of atrial activity. We report about a series of cases, in which conventional atrial pacemaker lead implantation in patients with symptomatic sinus node disease failed due to lack of excitable right atrial tissue, thus, prompting the diagnosis of atrial standstill. We hypothesized that mapping of the atria with subsequent identification of myocardium still amenable to atrial pacing would allow dual chamber pacemaker implantation. METHODS AND RESULTS: In four patients, atrial lead implantation failed. In these patients, spontaneous or fibrillatory electrical activity was absent but the atria could not be captured despite high stimulation voltages at conventional atrial sites. We suspected partial or complete atrial standstill and subsequently confirmed this hypothesis by conventional (n = 1) or electroanatomical mapping (n = 3). Areas of fibrotic tissue were present in all patients as identified by lack of spontaneous electrical activity and inability of local electrical capture via the mapping catheter. Surviving atrial tissue, which could be electrically captured with subsequent conduction of activity to the atrioventricular (AV) node, was present in three patients. Successful targeted atrial lead implantation at these sites was achieved in all these patients. Isolated sinus node activity without conduction to the atria was found in one patient. CONCLUSION: Partial atrial standstill may be present and prevent atrial lead implantation in patients with sinus node disease. In these patients, recognition of partial atrial standstill and identification of surviving muscular islets with connection to the AV node by mapping studies may still allow synchronous AV sequential pacing.


Assuntos
Função do Átrio Esquerdo , Função do Átrio Direito , Remodelamento Atrial , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Nó Sinoatrial/fisiopatologia , Adulto , Idoso , Ecocardiografia Doppler , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Fibrose , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/fisiopatologia , Fatores de Tempo , Sobrevivência de Tecidos , Resultado do Tratamento
16.
Herzschrittmacherther Elektrophysiol ; 26(4): 367-70, 2015 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-26350100

RESUMO

CASE REPORT: This article reports the case of a 76-year-old patient with multiple implantable cardioverter defibrillator (ICD) interventions of the single chamber ICD. On admission the 12-lead electrocardiogram (ECG) documented a wide QRS complex tachycardia without clearly identifiable P waves. The patient had previously had two ventricular tachycardia (VT) ablations due to VT storms. The resting ECG revealed a sinus rhythm with a wide QRS complex. During the electrophysiological investigation typical atrial flutter could be detected and an ablation of the cavotricuspid isthmus was performed. During the follow-up period, the patient has been free from tachycardia. CONCLUSION: The case described emphasizes that a differentiation between supraventricular tachycardia (SVT) and VT based on a stored ECG without an atrial channel can be challenging.


Assuntos
Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Eletrocardiografia/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade