Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. dor ; 18(1): 59-64, Jan.-Mar. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-845173

RESUMO

ABSTRACT BACKGROUND AND OBJECTIVES: This study aimed at identifying the prevalence of suspected temporomandibular disorders in employees and students of a Brazilian university and at evaluating the influence of socio-demographic and clinical variables on this disorder. METHODS: This study had a non-probabilistic sample of 575 volunteers who were evaluated by a questionnaire proposed by the American Academy of Orofacial Pain. RESULTS: Suspected temporomandibular disorder was present in 60.87% of the population. By means of multiple logistic regression analysis, just clinical variables were associated to the presence of suspected temporomandibular disorder, such as: headache, neck pain or teethache (OR=47.60), stiff, tight or regularly tired jaws (OR=13.37), mouth opening difficulty (OR=13.55) and pain around the ears, temples or cheeks (OR=4.61). CONCLUSION: The questionnaire was effective as a pre-screening tool to identify symptoms, and results support the importance of clinical symptoms for the identification and follow up of patients with such disorders.


RESUMO JUSTIFICATIVA E OBJETIVOS: O objetivo deste estudo foi identificar a prevalência de suspeita de disfunção temporomandibular em funcionários e estudantes em uma universidade no Brasil e analisar a influência das variáveis sócio-demográficas e clínicas sobre essa disfunção. MÉTODOS: Este estudo teve uma amostra não probabilística compreendendo 575 voluntários que foram avaliadas por um questionário, proposto pela Academia Americana de Dor Orofacial. RESULTADOS: A suspeita de disfunção temporomandibular estava presente em 60,87% da população. Por meio da análise de regressão logística múltipla, apenas variáveis clínicas foram associadas com a presença de suspeita de disfunção temporomandibular, como: apresentar cefaleia, dores no pescoço ou nos dentes (OR=47,60), maxilares rígidos, apertados ou cansados com regularidade (OR=13,37), dificuldade na abertura da boca (OR=13,55) e dor ao redor das orelhas, têmporas ou bochecha (OR=4,61). CONCLUSÃO: O questionário foi eficaz como um instrumento de pré-triagem no levantamento dos sintomas; e os resultados suportam o ponto forte dos sintomas clínicos na identificação e acompanhamento de indivíduos com tais lesões.

2.
Rio de Janeiro; s.n; 2011. 161 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-599334

RESUMO

Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (α), cerâmica de dissilicato de lítio (β) ou compósito fibrorreforçado (γ). Na composição α, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão...


Inlay-retained fixed partial dentures (IRFPD) are an alternative to osseointegrated implants to replace a single missing posterior tooth. The aim of this study was to evaluate the stress distribution within these prostheses with three material combinations: yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic veneered with fluorapatite ceramic (α), lithium-disilicate ceramic (β) or fiber-reinforced composite (γ). In composition α, an analysis was conducted on the presence or absence of the veneering ceramic on the cervical wall of the proximal boxes and three variations in the total area of the connectors’ cross-section (4 mm in width x 3.2, 4.2 or 5.2 mm in height). In 8 two-dimensional finite element models, a vertical load of 500 N was applied on the central fossa of the pontic. Maximum (tension) and minimum (compression) principal stresses were then shown in MPa. First, the 6 models with Y-TZP fixed partial dentures (FPD) and their variations were evaluated. The highest values of tensile stresses were found at the cervical third of the connectors. When present in these regions, the veneering ceramic received stresses beyond its flexural strength limit. In the comparison among models without veneering ceramic on the cervical wall of the proximal boxes, even the model with connectors of 3.2 x 4 mm, whose framework presented 2.5 x 3 mm, could be recommended for clinical use. High values of compressive stresses were recorded between the middle and occlusal thirds of the connectors, corresponding to the juncture of the ceramics. Owing to flexure, these stresses might lead to adhesive failures. Then, the Y-TZP model without fluorapatite ceramic on the cervical wall of the proximal boxes and total connector area of 4.2 x 4 mm was compared to the other two materials with connectors of the same area. For the lithium-disilicate FPD, the observed values would probably exceed its flexural strength limit...


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Cerâmica , Resinas Compostas , Prótese Parcial Fixa , Teste de Materiais , Análise de Elementos Finitos , Fenômenos Biomecânicos , Simulação por Computador , Modelos Dentários
3.
Rio de Janeiro; s.n; 2011. 161 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-865631

RESUMO

Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (α), cerâmica de dissilicato de lítio (β) ou compósito fibrorreforçado (γ). Na composição α, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão...


Inlay-retained fixed partial dentures (IRFPD) are an alternative to osseointegrated implants to replace a single missing posterior tooth. The aim of this study was to evaluate the stress distribution within these prostheses with three material combinations: yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic veneered with fluorapatite ceramic (α), lithium-disilicate ceramic (β) or fiber-reinforced composite (γ). In composition α, an analysis was conducted on the presence or absence of the veneering ceramic on the cervical wall of the proximal boxes and three variations in the total area of the connectors’ cross-section (4 mm in width x 3.2, 4.2 or 5.2 mm in height). In 8 two-dimensional finite element models, a vertical load of 500 N was applied on the central fossa of the pontic. Maximum (tension) and minimum (compression) principal stresses were then shown in MPa. First, the 6 models with Y-TZP fixed partial dentures (FPD) and their variations were evaluated. The highest values of tensile stresses were found at the cervical third of the connectors. When present in these regions, the veneering ceramic received stresses beyond its flexural strength limit. In the comparison among models without veneering ceramic on the cervical wall of the proximal boxes, even the model with connectors of 3.2 x 4 mm, whose framework presented 2.5 x 3 mm, could be recommended for clinical use. High values of compressive stresses were recorded between the middle and occlusal thirds of the connectors, corresponding to the juncture of the ceramics. Owing to flexure, these stresses might lead to adhesive failures. Then, the Y-TZP model without fluorapatite ceramic on the cervical wall of the proximal boxes and total connector area of 4.2 x 4 mm was compared to the other two materials with connectors of the same area. For the lithium-disilicate FPD, the observed values would probably exceed its flexural strength limit...


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Cerâmica , Resinas Compostas , Prótese Parcial Fixa , Teste de Materiais , Análise de Elementos Finitos , Fenômenos Biomecânicos , Simulação por Computador , Modelos Dentários
4.
Rev. bras. odontol ; 66(1): 60-64, jan.-jun. 2009. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-575386

RESUMO

Este relato de caso apresenta os benefícios estéticos da prótese parcial removível com eixo de inserção rotacional diante dos desafios e limitações característicos dessas reabilitações protéticas. O paciente queixava-se de instabilidade e pouca retenção de suas próteses parciais removíveis, além da má aparência de seu sorriso, comprometido pela exposição de uma porção metálica da estrutura superior e pela fratura do elemento protético 22. Para este arco, a prótese rotacional confeccionada possibilitou a colocação de componentes rígidos da estrutura metálica em regiões retentivas nas mesiais dos caninos, prescindindo dos braços de retenção vestibular nestes locais. Os autores pretendem contribuir para a difusão da técnica, que exige elevado apuro clínico e laboratorial, mas propicia resultados estéticos satisfatórios.


Assuntos
Humanos , Masculino , Idoso de 80 Anos ou mais , Retenção em Prótese Dentária , Planejamento de Dentadura , Prótese Parcial Removível
5.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 8(40): 108-114, abr.-jun.2006. ilus, tab, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853153

RESUMO

Este artigo faz o relato de um caso clínico de Disfunção Craniomandibular (DCM) em indivíduo do sexo feminino, 65 anos e portador de prótese total dupla. A paciente apresentou-se à clínica de Especialização em Prótese Dentária da Universidade Veiga de Almeida para confecção de novas próteses. Ao exame clínico, suspeitou-se de DCM e o diagnóstico foi confirmado pela avaliação do índice clínico e anamnésico modificado por Helkimo para disfunção. O tratamento foi efetuado devolvendo as características ideais de retenção, estabilidade, suporte e oclusão para prótese total e a redução da sintomatologia foi obtida dias após a entrega


Assuntos
Humanos , Feminino , Idoso , Transtornos Craniomandibulares , Prótese Total , Síndrome da Disfunção da Articulação Temporomandibular , Assistência Odontológica , Dentaduras , Inquéritos e Questionários , Sistema Estomatognático
6.
Acta cir. bras ; 20(5): 375-381, Sept.-Oct. 2005. ilus, tab
Artigo em Inglês | LILACS | ID: lil-414660

RESUMO

OBJETIVO: Avaliar ação protetora do alfa-tocoferol na lesão de isquemia e reperfusão em membro pélvico de ratos. MÉTODOS: Trinta ratos machos adultos da linhagem wistar foram distribuídos aleatoriamente, em três grupos experimentais, com 10 animais cada: Grupo I – Grupo controle sem isquemia ou reperfusão. Grupos II e III – quatro horas de isquemia e duas horas de reperfusão através clampeamento da aorta infra-renal. Os animais do grupo II foram tratados com solução salina e aqueles do grupo III, tratados com alfa-tocoferol 50 mg/kg por via endovenosa. Parâmetros estudados: Biópsias do músculo solear, dosagens da creatina fosfoquinase, da desidrogenasse láctica, do potássio, do cálcio e da hemogasometria arterial. RESULTADOS: Os resultados das biópsias dos músculos soleares estudados através da microscopia óptica, não foram significantes quanto a presença de edema entre os três grupos estudados. As variáveis inflamação e necrose não foram observadas e, portanto não analisáveis estatisticamente. Em relação às dosagens de cálcio e desidrogenase lática, pH, pO2, pCO2, não foram significantes em todos os grupos estudados. Observamos que os níveis de potássio (Grupo II > grupo I, F calculado = 5,84; F crítico = 3,33), creatina fosfoquinase (Grupo II > Grupo I e III, H calculado =13,92; Hcritico 5,99) , e bicarbonato (grupo I e III > grupo II, H calculado = 11,98; h critico 5.99 ) apresentaram resultados significantes entre os grupos. CONCLUSÃO: Tratamento com alfa-tocoferol do ponto de vista bioquímico sérico atenuou as lesões metabólicas na síndrome de isquemia e reperfusão neste modelo experimental.


Assuntos
Animais , Masculino , Ratos , Antioxidantes/farmacologia , Músculo Esquelético/patologia , Pelve/irrigação sanguínea , Traumatismo por Reperfusão/prevenção & controle , alfa-Tocoferol/farmacologia , Análise de Variância , Antioxidantes/metabolismo , Biópsia , Bicarbonatos/sangue , Distribuição de Qui-Quadrado , Creatina Quinase/sangue , Modelos Animais de Doenças , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiopatologia , Pelve/patologia , Potássio/sangue , Ratos Wistar , Traumatismo por Reperfusão/metabolismo , Traumatismo por Reperfusão/patologia , alfa-Tocoferol/sangue
7.
Acta Cir Bras ; 20(5): 375-81, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16186962

RESUMO

PURPOSE: To evaluate the protective action of alpha-tocopherol in ischemia/reperfusion injuries of pelvic member of rats. METHODS: Thirty adult male rats of the Wistar strain were randomized into three experimental groups of 10: Group I--control group with no ischemia or reperfusion. Groups II and III--four hours of ischemia and of hours of reperfusion by means of clamping of the infrarenal aorta. The animals of Group II were treated with saline and those of Group III were treated with i.v. alpha-tocopherol (50 mg/kg). Parameters studied were biopsies of the soleus muscle, dosing of creatine phosphokinase, lactate dehydrogenase, potassium, calcium and arterial blood gasometry. RESULTS: The results of biopsies of the soleus muscles studied by optical microscopy, were not significant in terms of presence of edema among the three groups studied. Variables inflammation and necrosis were not observed, therefore cannot be statistically analyzed. As to dosing of calcium and lactate dehydrogenase, the pH, pO2 and pCO2 values were not significant for all groups studied. We observed that the levels of potassium (Group II > Group I, Fcalculated = 5.84; Fcritical = 3.33), creatine phosphokinase (Group II > Groups I and III, Hcalculated = 13.92; Hcritical = 5.99) and bicarbonate (Groups I and III > Group II, Hcalculated = 11.98; Hcritical = 5.99) presented significant results among groups. CONCLUSION: From the serum biochemical perspective, the treatment with alpha-tocopherol has attenuated the metabolic injuries in the ischemia/reperfusion syndrome in this experimental model.


Assuntos
Antioxidantes/farmacologia , Músculo Esquelético/patologia , Pelve/irrigação sanguínea , Traumatismo por Reperfusão/prevenção & controle , alfa-Tocoferol/farmacologia , Análise de Variância , Animais , Antioxidantes/metabolismo , Bicarbonatos/sangue , Biópsia , Distribuição de Qui-Quadrado , Creatina Quinase/sangue , Modelos Animais de Doenças , Masculino , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiopatologia , Pelve/patologia , Potássio/sangue , Ratos , Ratos Wistar , Traumatismo por Reperfusão/metabolismo , Traumatismo por Reperfusão/patologia , alfa-Tocoferol/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...