Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Acute Cardiovasc Care ; : 2048872619853579, 2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-31976746

RESUMO

BACKGROUND: Recent advances in digital electrocardiography technology allow evaluating ST-segment deviations in all 12 leads as quantitative variables and calculating summed ST-segment deviation scores. The diagnostic and prognostic utility of summed ST-segment deviation scores is largely unknown. METHODS: We aimed to explore the diagnostic and prognostic utility of the conventional and the modified ST-segment deviation score (Better Analysis of ST-segment Elevations and Depressions in a 12- Lead-ECG-Score (BASEL-Score): sum of elevations in the augmented voltage right - lead (aVR) plus absolute, unsigned ST-segment depressions in the remaining leads) in patients presenting with suspected non-ST-segment elevation myocardial infarction. The diagnostic endpoint was non-ST-segment elevation myocardial infarction, adjudicated by two independent cardiologists. Prognostic endpoint was mortality during two-year follow up. RESULTS: Among 1330 patients, non-ST-segment elevation myocardial infarction was present in 200 (15%) patients. Diagnostic accuracy for non-ST-segment elevation myocardial infarction as quantified by the area under the receiver-operating-characteristics curve was significantly higher for the BASEL-Score (0.73; 95% confidence interval 0.69-0.77) as compared to the conventional ST-segment deviation score (0.53; 95% confidence interval 0.49-0.57, p<0.001). The BASEL-Score provided additional independent diagnostic value to dichotomous electrocardiogram variables (ST-segment depression, T-inversion, both p<0.001) and to high-sensitivity cardiac troponin (p<0.001) as well as clinical judgment at 90 min (p<0.001). Similarly, only the BASEL-Score proved to be an independent predictor of two year mortality. CONCLUSIONS: The modified ST-segment deviation score BASEL-Score focusing on ST-segment elevation in aVR and ST-segment depressions in the remaining leads provides incremental diagnostic and prognostic information.

2.
Clin Chem ; 65(11): 1426-1436, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31570633

RESUMO

BACKGROUND: We aimed to validate the clinical performance of the high-sensitivity cardiac troponin I [VITROS® Immunodiagnostic Products hs Troponin I (hs-cTnI-VITROS)] assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists considering all clinical information, including cardiac imaging: first, using serial hs-cTnT-Elecsys (primary analysis) and, second, using hs-cTnI-Architect (secondary analysis) measurements in addition to the clinically used (hs)-cTn. hs-cTnI-VITROS was measured at presentation and at 1 h in a blinded fashion. The primary objective was direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI-VITROS vs hs-cTnT-Elecsys and hs-cTnI-Architect, and in a subgroup also hs-cTnI-Centaur and hs-cTnI-Access. Secondary objectives included the derivation and validation of an hs-cTnI-VITROS-0/1-h algorithm. RESULTS: AMI was the adjudicated final diagnosis in 158 of 1231 (13%) patients. At presentation, the AUC for hs-cTnI-VITROS was 0.95 (95% CI, 0.93-0.96); for hs-cTnT-Elecsys, 0.94 (95% CI, 0.92-0.95); and for hs-cTnI-Architect, 0.92 (95% CI, 0.90-0.94). AUCs for hs-cTnI-Centaur and hs-cTnI-Access were 0.95 (95% CI, 0.94-0.97). Applying the derived hs-cTnI-VITROS-0/1-h algorithm (derivation cohort n = 519) to the validation cohort (n = 520), 53% of patients were ruled out [sensitivity, 100% (95% CI, 94.1-100)] and 14% of patients were ruled in [specificity, 95.6% (95% CI, 93.4-97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 99.8% at 30 days. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI-Architect. CONCLUSIONS: The hs-cTnI-VITROS assay has at least comparable diagnostic accuracy with the currently best validated hs-cTnT and hs-cTnI assays. CLINICALTRIALSGOV IDENTIFIER: NCT00470587.

3.
Clin Chem ; 65(11): 1437-1447, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31570634

RESUMO

BACKGROUND: We aimed to derive and externally validate a 0/2-h algorithm using the high-sensitivity cardiac troponin I (hs-cTnI)-Access assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI) in 2 prospective diagnostic studies using central adjudication. Two independent cardiologists adjudicated the final diagnosis, including all available medical information including cardiac imaging. hs-cTnI-Access concentrations were measured at presentation and after 2 h in a blinded fashion. RESULTS: AMI was the adjudicated final diagnosis in 164 of 1131 (14.5%) patients in the derivation cohort. Rule-out by the hs-cTnI-Access 0/2-h algorithm was defined as 0-h hs-cTnI-Access concentration <4 ng/L in patients with an onset of chest pain >3 h (direct rule-out) or a 0-h hs-cTnI-Access concentration <5 ng/L and an absolute change within 2 h <5 ng/L in all other patients. Derived thresholds for rule-in were a 0-h hs-cTnI-Access concentration ≥50 ng/L (direct rule-in) or an absolute change within 2 h ≥20 ng/L. In the derivation cohort, these cutoffs ruled out 55% of patients with a negative predictive value (NPV) of 99.8% (95% CI, 99.3-100) and sensitivity of 99.4% (95% CI, 96.5-99.9), and ruled in 30% of patients with a positive predictive value (PPV) of 73% (95% CI, 66.1-79). In the validation cohort, AMI was the adjudicated final diagnosis in 88 of 1280 (6.9%) patients. These cutoffs ruled out 77.9% of patients with an NPV of 99.8% (95% CI, 99.3-100) and sensitivity of 97.7% (95% CI, 92.0-99.7), and ruled in 5.8% of patients with a PPV of 77% (95% CI, 65.8-86) in the validation cohort. CONCLUSIONS: Safety and efficacy of the l hs-cTnI-Access 0/2-h algorithm for triage toward rule-out or rule-in of AMI are very high. TRIAL REGISTRATION: APACE, NCT00470587; ADAPT, ACTRN1261100106994; IMPACT, ACTRN12611000206921.

4.
J Am Coll Cardiol ; 74(7): 842-854, 2019 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-31416527

RESUMO

BACKGROUND: Early and accurate detection of short-term major adverse cardiac events (MACE) in patients with suspected acute myocardial infarction (AMI) is an unmet clinical need. OBJECTIVES: The goal of this study was to test the hypothesis that adding clinical judgment and electrocardiogram findings to the European Society of Cardiology (ESC) high-sensitivity cardiac troponin (hs-cTn) measurement at presentation and after 1 h (ESC hs-cTn 0/1 h algorithm) would further improve its performance to predict MACE. METHODS: Patients presenting to an emergency department with suspected AMI were enrolled in a prospective, multicenter diagnostic study. The primary endpoint was MACE, including all-cause death, cardiac arrest, AMI, cardiogenic shock, sustained ventricular arrhythmia, and high-grade atrioventricular block within 30 days including index events. The secondary endpoint was MACE + unstable angina (UA) receiving early (≤24 h) revascularization. RESULTS: Among 3,123 patients, the ESC hs-cTnT 0/1 h algorithm triaged significantly more patients toward rule-out compared with the extended algorithm (60%; 95% CI: 59% to 62% vs. 45%; 95% CI: 43% to 46%; p < 0.001), while maintaining similar 30-day MACE rates (0.6%; 95% CI: 0.3% to 1.1% vs. 0.4%; 95% CI: 0.1% to 0.9%; p = 0.429), resulting in a similar negative predictive value (99.4%; 95% CI: 98.9% to 99.6% vs. 99.6%; 95% CI: 99.2% to 99.8%; p = 0.097). The ESC hs-cTnT 0/1 h algorithm ruled-in fewer patients (16%; 95% CI: 14.9% to 17.5% vs. 26%; 95% CI: 24.2% to 27.2%; p < 0.001) compared with the extended algorithm, albeit with a higher positive predictive value (76.6%; 95% CI: 72.8% to 80.1% vs. 59%; 95% CI: 55.5% to 62.3%; p < 0.001). For 30-day MACE + UA, the ESC hs-cTnT 0/1 h algorithm had a higher positive predictive value for rule-in, whereas the extended algorithm had a higher negative predictive value for the rule-out. Similar findings emerged when using hs-cTnI. CONCLUSIONS: The ESC hs-cTn 0/1 h algorithm better balanced efficacy and safety in the prediction of MACE, whereas the extended algorithm is the preferred option for the rule-out of 30-day MACE + UA. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587).

5.
J Am Coll Cardiol ; 74(4): 483-494, 2019 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-31345421

RESUMO

BACKGROUND: The European Society of Cardiology (ESC) recommends the 0/1-h algorithm for rapid triage of patients with suspected non-ST-segment elevation myocardial infarction (MI). However, its impact on patient management and safety when routinely applied is unknown. OBJECTIVES: This study sought to determine these important real-world outcome data. METHODS: In a prospective international study enrolling patients presenting with acute chest discomfort to the emergency department (ED), the authors assessed the real-world performance of the ESC 0/1-h algorithm using high-sensitivity cardiac troponin T embedded in routine clinical care and its associated 30-day rates of major adverse cardiac events (MACE) (the composite of cardiovascular death and MI). RESULTS: Among 2,296 patients, non-ST-segment elevation MI prevalence was 9.8%. In median, 1-h blood samples were collected 65 min after the 0-h blood draw. Overall, 94% of patients were managed without protocol violations, and 98% of patients triaged toward rule-out did not require additional cardiac investigations including high-sensitivity cardiac troponin T measurements at later time points or coronary computed tomography angiography in the ED. Median ED stay was 2 h and 30 min. The ESC 0/1-h algorithm triaged 62% of patients toward rule-out, and 71% of all patients underwent outpatient management. Proportion of patients with 30-day MACE were 0.2% (95% confidence interval: 03% to 0.5%) in the rule-out group and 0.1% (95% confidence interval: 0% to 0.2%) in outpatients. Very low MACE rates were confirmed in multiple subgroups, including early presenters. CONCLUSIONS: These real-world data document the excellent applicability, short time to ED discharge, and low rate of 30-day MACE associated with the routine clinical use of the ESC 0/1-h algorithm for the management of patients presenting with acute chest discomfort to the ED.

6.
Clin Chem ; 65(7): 893-904, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30988172

RESUMO

BACKGROUND: The aim of this study was to validate the clinical performance of the Beckman Access high-sensitivity cardiac troponin I (hs-cTnI) assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists with all clinical information including cardiac imaging twice: first, using serial hs-cTnT (Elecsys, primary analysis), and second, using hs-cTnI (Architect, secondary analysis) measurements in addition to the clinically used hs-cTn. hs-cTnI Access was measured at presentation and at 1 h. The primary objective was a direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI Access vs the hs-cTnT Elecsys and hs-cTnI Architect assays. Secondary objectives included the derivation and validation of an hs-cTnI Access-specific 0/1-h algorithm. RESULTS: AMI was the adjudicated final diagnosis in 243 of 1579 (15.4%) patients. The AUC at presentation for hs-cTnI Access was 0.95 (95% CI, 0.94-0.96), higher than hs-cTnI Architect [0.92 (95% CI, 0.91-0.94; P < 0.001)] and comparable to hs-cTnT Elecsys [0.94 (95% CI, 0.93-0.95; P = 0.12)]. Applying the derived hs-cTnI Access 0/1-h algorithm (derivation cohort n = 686) to the validation cohort (n = 680), 60% of patients were ruled out [sensitivity, 98.9% (95% CI, 94.3-99.8)], and 15% of patients were ruled in [specificity, 95.9% (95% CI, 94.0-97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 100% at 30 days. Findings were confirmed in the secondary analyses by the adjudication including serial measurements of Architect hs-cTnI. CONCLUSIONS: Diagnostic accuracy and clinical utility of the Beckman hs-cTnI Access assay are very high and at least comparable to Roche hs-cTnT and Abbott hs-cTnI assays. ClinicalTrials.gov Identifier: NCT00470587.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA