Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 29(7): 10285-10306, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33820168

RESUMO

This paper presents a passive autofocus algorithm applicable to interferometric microscopes. The proposed algorithm uses the number of slope variations in an image mask to locate the focal plane (based on focus-inflection points) and identify the two neighboring planes at which fringes respectively appear and disappear. In experiments involving a Mirau objective lens, the proposed algorithm matched the autofocusing performance of conventional algorithms, and significantly outperformed detection schemes based on zero-order interference fringe in dealing with all kinds of surface blemish, regardless of severity. In experiments, the proposed algorithm also proved highly effective in cases without fringes.

2.
Opt Express ; 23(24): 30815-20, 2015 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-26698714

RESUMO

A confocal microspectrophotometer is utilized to scan the surface reflectivities of a polished gradient-index (GRIN) rod in the range of 400 to 900 nm. The pure fused silica is used to be a reference standard for deducing the absolute reflectivities of the Ge-doped core. Then, multi-wavelength refractive index profiles of the Ge-doped core can be further determined based on the Fresnel equation. Moreover, this work shows a connection between the material dispersion of the GRIN rod and the Ge-doped concentrations measured by an energy dispersive spectrometer. Finally, the dependence of the refractive index of the Ge-doped core on the doping concentrations at a certain wavelength can be easily expressed as a linear form.

3.
Opt Express ; 23(9): 11755-62, 2015 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-25969266

RESUMO

A direct image method of surface reflectivities on a cleaved fiber end with a filtered halogen lamp and a TE-cooled CCD with high dynamic range is proposed to measure the multi-wavelength refractive index profiling (RIP). A polished black glass is used to be a reference standard for measuring the absolute reflectivity of the fiber end. With the developed calibration procedures, both the spatially dependent sensitivity and spectral responsivity of the CCD pixels can be eliminated to achieve the high spatial accuracy. Tested fiber is connected with a fiber terminator to prevent errors from the backside return light. With the present method, the RIP can be precisely measured for not only multi-mode fibers but also single-mode fibers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...