Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Exp Dent Res ; 9(2): 322-331, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36866428

RESUMO

INTRODUCTION: An ideal filling material should hermetically seal the communication pathways between the canal system and surrounding tissues. Therefore, during the last few years, the development of obturation materials and techniques to create optimal conditions for the proper healing of apical tissues has been a focus of interest. The effects of calcium silicate-based cements (CSCs) on periodontal ligament cells have been investigated, and promising results have been obtained. To date, there are no reports in the literature that have evaluated the biocompatibility of CSCs using a real-time live cell system. Therefore, this study aimed to evaluate the real-time biocompatibility of CSCs with human periodontal ligament cells (hPDLCs). METHODOLOGY: hPDLC were cultured with testing media of endodontic cements for 5 days: TotalFill-BC Sealer, BioRoot RCS, Tubli-Seal, AH Plus, MTA ProRoot, Biodentine, and TotalFill-BC RRM Fast Set Putty. Cell proliferation, viability, and morphology were quantified using real-time live cell microscopy with the IncuCyte S3 system. Data were analyzed using the one-way repeated measures (RM) analysis of variance multiple comparison test (p < .05). RESULTS: Compared to the control group, cell proliferation in the presence of all cements was significantly affected at 24 h (p < .05). ProRoot MTA and Biodentine lead to an increase in cell proliferation; there were no significant differences with the control group at 120 h. In contrast, Tubli-Seal and TotalFill-BC Sealer inhibited cell growth in real-time and significantly increased cell death compared to all groups. hPDLC co-cultured with sealer and repair cements showed a spindle-shaped morphology except with cements Tubli-Seal and TotalFill-BC Sealer where smaller and rounder cells were obtained. CONCLUSIONS: The biocompatibility of the endodontic repair cements performed better than the sealer cements, highlighting the cell proliferation of the ProRoot MTA and Biodentine in real-time. However, the calcium silicate-based TotalFill-BC Sealer presented a high percentage of cell death throughout the experiment similar to that obtained.


Assuntos
Compostos de Cálcio , Silicatos , Humanos , Teste de Materiais , Compostos de Cálcio/farmacologia , Silicatos/farmacologia
2.
Biomedicines ; 9(8)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34440236

RESUMO

Engineered vaccinia virus (VACV) strains are used extensively as vectors for the development of novel cancer vaccines and cancer therapeutics. In this study, we describe for the first time a high-throughput approach for both fluorescent rVACV generation and rapid viral titer measurement with the multi-well plate imaging system, IncuCyte®S3. The isolation of a single, well-defined plaque is critical for the generation of novel recombinant vaccinia virus (rVACV) strains. Unfortunately, current methods of rVACV engineering via plaque isolation are time-consuming and laborious. Here, we present a modified fluorescent viral plaque screening and selection strategy that allows one to generally obtain novel fluorescent rVACV strains in six days, with a minimum of just four days. The standard plaque assay requires chemicals for fixing and staining cells. Manual plaque counting based on visual inspection of the cell culture plates is time-consuming. Here, we developed a fluorescence-based plaque assay for quantifying the vaccinia virus that does not require a cell staining step. This approach is less toxic to researchers and is reproducible; it is thus an improvement over the traditional assay. Lastly, plaque counting by virtue of a fluorescence-based image is very convenient, as it can be performed directly on the computer.

3.
Methods Protoc ; 4(1)2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33672596

RESUMO

Stable cell lines are widely used in laboratory research and pharmaceutical industry. They are mainly applied in recombinant protein and antibody productions, gene function studies, drug screens, toxicity assessments, and for cancer therapy investigation. There are two types of cell lines, polyclonal and monoclonal origin, that differ regarding their homogeneity and heterogeneity. Generating a high-quality stable cell line, which can grow continuously and carry a stable genetic modification without alteration is very important for most studies, because polyclonal cell lines of multicellular origin can be highly variable and unstable and lead to inconclusive experimental results. The most commonly used technologies of single cell originate monoclonal stable cell isolation in laboratory are fluorescence-activated cell sorting (FACS) sorting and limiting dilution cloning. Here, we describe a modified limiting dilution method of monoclonal stable cell line selection using the real-time fluorescence imaging system IncuCyte®S3.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA