Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 32(5): 290-293, sept.-oct. 2013.
Artigo em Espanhol | IBECS | ID: ibc-115143

RESUMO

Introducción: Tras el cese en la fabricación de ITLC-SG por Pall-Gelman, es necesaria la validación de fases estacionarias alternativas. Objetivo: Validar diferentes fases estacionarias frente a ITLC-SG de Pall-Gelman en la determinación de la pureza radioquímica (PRQ) de 111In-pentetreótida (111In-Octreoscan) por cromatografía planar. Material y métodos: Realizamos un estudio caso-control en el que incluimos 66 preparaciones de 111In-pentetreótida. Determinamos la PRQ mediante cromatografía plana, empleando una solución recién preparada de citrato de sodio de 0,1 M (pH 5) y las siguientes fases estacionarias: ITLC-SG (Pall-Gelman) (método de referencia), iTLC-SG (Varian), Silicagel 60 HPTLC (Merck), Whatman 1, Whatman 3 MM y Whatman 17. Para cada uno de los métodos calculamos: PRQ, factores de retención (RF) del radiofármaco e 111In libre, tiempo de desarrollo cromatográfico y resolución entre picos. Comparamos los resultados obtenidos con los del método de referencia. Para el análisis estadístico de datos utilizamos el programa SPSS. Para el estudio de significación estadística calculamos el valor de p. Resultados: Con Silicagel 60 HPTLC (Merck) se obtiene la mayor resolución, aunque el tiempo de desarrollo cromatográfico es prolongado (media = 33,62 min). Con iTLC-SG (Varian) se obtiene una resolución mayor que con el método de referencia, siendo menor el tiempo de desarrollo cromatográfico (media = 3,61 min). Con papel Whatman se obtienen resoluciones muy bajas, fundamentalmente con Whatman 1 y 3 MM, por lo que no recomendamos su utilización. Conclusiones. Aunque iTLC-SG (Varian) y Silicagel 60 HPTLC (Merck) son alternativas adecuadas a ITLC-SG (Pall-Gelman) en la determinación de la PRQ de 111In-pentetreótida, iTLC-SG (Varian) es el método de elección por su menor tiempo de desarrollo cromatográfico(AU)


Introduction: Since Pall-German stopped manufacturing ITLC-SG, it has become necessary to validate alternative stationary phases. Objective: To validate different stationary phases versus ITLC-SG Pall-Gelman in the determination of the radiochemical purity (RCP) of 111In-pentetreotide (111In-Octreoscan) by planar chromatography. Material and methods: We conducted a case-control study, which included 66 111In-pentetreotide preparations. We determined the RCP by planar chromatography, using a freshly prepared solution of 0,1 M sodium citrate (pH 5) and the following stationary phases: ITLC-SG (Pall-Gelman) (reference method), iTLC-SG (Varian), HPTLC silica gel 60 (Merck), Whatman 1, Whatman 3 MM and Whatman 17. For each of the methods, we calculated: PRQ, relative front values (RF) of the radiopharmaceutical and free 111In, chromatographic development time, resolution between peaks. We compared the results obtained with the reference method. The statistical analysis was performed using the SPSS program. The p value was calculated for the study of statistical significance. Results: The highest resolution is obtained with HPTLC silica gel 60 (Merck). However, the chromatographic development time is too long (mean = 33.62 minutes). Greater resolution is obtained with iTLC-SG (Varian) than with the reference method, with lower chromatographic development time (mean = 3.61 minutes). Very low resolutions are obtained with Whatman paper, essentially with Whatman 1 and 3 MM. Therefore, we do not recommend their use. Conclusions: Although iTLC-SG (Varian) and HPTLC silica gel 60 (Merck) are suitable alternatives to ITLC-SG (Pall-Gelman) in determining the RCP of 111In-pentetreotide, iTLC-SG (Varian) is the method of choice due to its lower chromatographic development time(AU)


Assuntos
Humanos , Masculino , Feminino , Cromatografia/instrumentação , Cromatografia/métodos , Cromatografia , Compostos Radiofarmacêuticos , Radioquímica/métodos , Radioquímica/organização & administração , Radioquímica/normas
2.
Appl Radiat Isot ; 68(7-8): 1282-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20018513

RESUMO

The first inter-laboratory comparison organized by the radiochemistry laboratory of Water Research Institute (WRI) in Bratislava was carried out in 1993 and since then is it realized on an annual basis and about 10 radiochemical laboratories from all over Slovakia are participating. The gross alpha and gross beta activities, and the activity concentrations of (222)Rn, tritium, and (226)Ra, and U(nat) concentration in synthetic water samples are compared. The distributed samples are covering the concentration range prevailing in potable and surface waters and are prepared by dilution of certified reference materials. Over the course of the years 1993-2008, we observed the improvement in the quality of results for most of the laboratories. However, the success rate of the gross alpha determination activity is not improving as much as the other parameters.


Assuntos
Laboratórios/normas , Poluentes Radioativos da Água/análise , Poluentes Radioativos da Água/normas , Variações Dependentes do Observador , Controle de Qualidade , Radioquímica/métodos , Radioquímica/organização & administração , Rádio (Elemento)/análise , Padrões de Referência , Eslováquia , Trítio/análise , Urânio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA