Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
Sleep Med ; 123: 29-36, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39232262

RESUMO

INTRODUCTION: The apnea-hypopnea index (AHI) is the current diagnostic parameter for diagnosing and estimating the severity of obstructive sleep apnea (OSA). It is, however, poorly associated with the main clinical symptom of OSA, excessive daytime sleepiness, and with the often-seen cognitive decline among OSA patients. To better evaluate OSA severity, novel hypoxic load parameters have been introduced that consider the duration and depth of oxygen saturation drops associated with apneas or hypopneas. The aim of this paper was to compare novel hypoxic load parameters and traditional OSA parameters to verbal memory and executive function in OSA patients. METHOD: A total of 207 adults completed a one-night polysomnography at sleep laboratory and two neuropsychological assessments, the Rey Auditory Verbal Learning Test and Stroop test. RESULTS: Simple linear regression analyses were used to evaluate independent associations between each OSA parameter and cognitive performance. Associations were found between immediate recall and arousal index, hypoxia <90 %, average SpO2 during sleep, and DesSev100+RevSev100. Total recall was associated with all OSA parameters, and no associations were found with the Stroop test. Subsequently, sex, age, and education were included as covariates in multiple linear regression analyses for each OSA parameter and cognitive performance. The main findings of the study were that average SpO2 during sleep was a significant predictor of total recall (p < .007, ß = -.188) with the regression model explaining 21.2 % of performance variation. Average SpO2 during sleep was also a significant predictor of immediate recall (p < .022, ß = -.171) with the regression model explaining 11.4 % of performance variation. Neither traditional OSA parameters nor novel hypoxic load parameters predicted cognitive performance after adjustment for sex, age, and education. CONCLUSION: The findings validate that the AHI is not an effective indicator of cognitive performance in OSA and suggest that average oxygen saturation during sleep may be the strongest PSG predictor of cognitive decline seen in OSA. The results also underline the importance of considering age when choosing neurocognitive tests, the importance of including more than one test for each cognitive domain as most tests are not pure measures of a single cognitive factor, and the importance of including tests that cover all cognitive domains as OSA is likely to have diffuse cognitive effects.


Assuntos
Hipóxia , Testes Neuropsicológicos , Saturação de Oxigênio , Polissonografia , Apneia Obstrutiva do Sono , Humanos , Masculino , Feminino , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/diagnóstico , Pessoa de Meia-Idade , Adulto , Hipóxia/fisiopatologia , Saturação de Oxigênio/fisiologia , Testes Neuropsicológicos/estatística & dados numéricos , Aprendizagem Verbal/fisiologia , Sono/fisiologia , Função Executiva/fisiologia , Índice de Gravidade de Doença , Memória/fisiologia
2.
J Biomed Opt ; 29(Suppl 3): S33310, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39323492

RESUMO

Significance: Near-infrared spectroscopy (NIRS) is a non-invasive optical method that measures changes in hemoglobin concentration and oxygenation. The measured light intensity is susceptible to reduced signal quality due to the presence of melanin. Aim: We quantify the influence of melanin concentration on NIRS measurements taken with a frequency-domain near-infrared spectroscopy system using 690 and 830 nm. Approach: Using a forehead NIRS probe, we measured 35 healthy participants and investigated the correlation between melanin concentration indices, which were determined using a colorimeter, and several key metrics from the NIRS signal. These metrics include signal-to-noise ratio (SNR), two measurements of oxygen saturation (arterial oxygen saturation, SpO 2 , and tissue oxygen saturation, StO 2 ), and optical properties represented by the absorption coefficient ( µ a ) and the reduced scattering coefficient ( µ s ' ). Results: We found a significant negative correlation between the melanin index and the SNR estimated in oxy-hemoglobin signals ( r s = - 0.489 , p = 0.006 ) and SpO 2 levels ( r s = - 0.413 , p = 0.023 ). However, no significant changes were observed in the optical properties and StO 2 ( r s = - 0.146 , p = 0.44 ). Conclusions: We found that estimated SNR and SpO 2 values show a significant decline and dependence on the melanin index, whereas StO 2 and optical properties do not show any correlation with the melanin index.


Assuntos
Melaninas , Razão Sinal-Ruído , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Melaninas/análise , Melaninas/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Feminino , Adulto , Adulto Jovem , Saturação de Oxigênio/fisiologia , Oxigênio/metabolismo , Oxiemoglobinas/análise , Oximetria/métodos , Hemoglobinas/análise
3.
Georgian Med News ; (351): 44-48, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39230219

RESUMO

INTRODUCTION: The adenoids and palatine tonsils, part of the lymphoid tissue, act as a first line of defense protecting the lower airways and gastrointestinal tract. Adenotonsillar hypertrophy in children may lead to airway obstruction. This study aims to demonstrate the association between adenotonsillar hypertrophy and decreased blood oxygen saturation. METHODS: A retrospective cohort study was conducted among children aged 7-12 years with adenotonsillar hypertrophy and obstructive symptoms, admitted to King Fahad Hospital and Prince Mishari Hospital, Saudi Arabia, for tonsillectomy between July 2023 and January 2024. Exclusion criteria included respiratory diseases, cardiac disease, nasal polyps, nasal septum deviation, chest wall abnormality, and lower airway diseases. The control group included 56 healthy children. An otolaryngologist determined the severity of airway obstruction using the tonsil size. Oxygen saturation was measured using pulse oximetry. The determinants of oxygen saturation were assessed using multiple linear regression, with significance set at p<0.05. RESULTS: The study included 357 participants, with an even age distribution between 7-9 years (49.6%) and 10-12 years (50.4%), and 52% males. Diagnoses included adenoid hypertrophy (30%), tonsil hypertrophy (35%), both conditions (19%), and the control group (16%). Tonsil sizes ranged from Grade 1 (48%) to Grade 4 (8.4%), with 17% normal. The median oxygen saturation was 96.0% for the adenotonsillar hypertrophy group and 99.0% for the control. Oxygen saturation levels differed significantly across groups (p<0.0001), with lower median saturation in hypertrophy groups than controls. Males had a lower oxygen than females (estimate: -0.338, 95% CI [--0.640, -0.036], p=0.028). Adenoid hypertrophy (estimate: -3.863, 95% CI [-5.241, -2.484], p<0.001), tonsil hypertrophy (estimate: -3.631, 95% CI [-5.053, -2.208], p<0.001) and having both conditions (estimate: -3.777, 95% CI [-5.3.7, -2.247], p<0.001) was associated with lower oxygen saturation. Grade 1 tonsil size was associated with an increase in oxygen saturation (estimate = 2.905, 95% CI [1.616, 4.194], p<0.001). In contrast, Grade 4 tonsil size was linked to lower oxygen saturation (estimate=-4.848, 95% CI [-6.367, -3.329], p<0.001). Grades 2 and 3 were not significantly associated with changes in oxygen saturation. CONCLUSION: Adenotonsillar hypertrophy is significantly associated with decreased blood oxygen saturation and related cardiopulmonary complications in children. Early adenotonsillectomy may be of benefit in preventing these complications and improving oxygen saturation levels.


Assuntos
Tonsila Faríngea , Hipertrofia , Saturação de Oxigênio , Tonsila Palatina , Humanos , Tonsila Faríngea/patologia , Criança , Masculino , Feminino , Arábia Saudita , Tonsila Palatina/patologia , Estudos Retrospectivos , Saturação de Oxigênio/fisiologia , Tonsilectomia , Obstrução das Vias Respiratórias/sangue , Obstrução das Vias Respiratórias/patologia , Oximetria
4.
Sleep Med ; 122: 258-265, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39217970

RESUMO

STUDY OBJECTIVE: To evaluate the sensitivity and specificity of the combined Kushida morphometric model (KMM) and the oxygen desaturation index (ODI) for screening individuals with obstructive sleep apnea. METHODS: Diagnostic test study with adults >18 years, both sexes, polysomnography, body mass index, neck circumference and intraoral measurements. RESULTS: 144 patients were invited; of these, 75 met the exclusion criteria. 55 individuals presented AHI ≥5 ev/h and 14, an AHI <5 ev/h. Three AHI cut-off points were evaluated: AHI ≥5, ≥15, ≥30 ev/h. When adopting the cut-off point of AHI ≥5 ev/h, the KMM showed sensitivity (SE) = 60.0 %, specificity (SP) = 71.4 % and 95 % confidence interval of the area under the curve (95 % CI of AUC) = 0.655; the combination of KMM and ODI (KMM + ODI) revealed SE = 73.0 %, SP = 71.4 % (95 % CI of AUC = 0.779) and the ODI showed SE = 76.4 % and SP = 92.9 % (95 % CI of AUC = 0.815). At the cut-off point of AHI ≥15 ev/h, the KMM presented SE = 64.1 %, SP = 76.7 % (95 % CI of AUC = 0.735); the KMM + ODI showed SE = 82.1 %, SP = 83.3 % (95 % CI of AUC = 0.895); and the ODI presented SE = 76.9 %, SP = 100.0 % (95 % CI of AUC = 0.903). For the cut-off point of AHI ≥30 ev/h, the KMM showed SE = 56.0 %, SP = 77.2 % (95 % CI of AUC = 0.722); the KMM + ODI revealed SE = 92.0 %, SP = 79.5 % (95 % CI of AUC = 0.926); and the ODI showed SE = 92.0 %, SP = 90.9 % (95 % CI of AUC = 0.941). CONCLUSION: The combination of oxygen desaturation index and Kushida morphometric model improved the sensitivity and specificity of this model regardless of obstructive sleep apnea severity suggesting greater effectiveness in risk prediction.


Assuntos
Índice de Massa Corporal , Polissonografia , Sensibilidade e Especificidade , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Saturação de Oxigênio/fisiologia , Programas de Rastreamento/métodos , Pescoço/anatomia & histologia
6.
Turk Neurosurg ; 34(5): 794-801, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39087284

RESUMO

AIM: To examine the effects of different retractor techniques for anterior cervical discectomy on cerebral oxygen saturation. MATERIAL AND METHODS: In this study, a prospective comparative design was employed to examine the effects of different retractor techniques on a cohort of 48 adult patients with ASA I-II classification who underwent anterior cervical discectomy under general anesthesia. The study was conducted under assessor-blinded conditions, and the patients were divided equally into two groups: the self-retaining retractor group and the hand-held retractor group. In addition to standard anaesthesia monitoring, the utilization of cerebral oximetry monitoring was implemented for all patients. A total of 7 measurements were obtained at various stages, including preoperative, during anaesthesia induction, surgical positioning, surgical retraction, release of retractors, after correction of extension position, and prior to extubation. The main objective of this study was to evaluate the impact of neck position and surgical retraction on brain perfusion, as measured by regional cerebral oximetry. RESULTS: Sociodemographic data, duration of operation, hemodynamic parameters, bilateral regional cerebral oxygen saturation (rScO2), and Mini Mental State Examination (MMSE) scores did not differ significantly between the two groups. In both groups, the bilateral rScO2 decreased significantly with positioning and the left rScO2 decreased significantly following the installation of retractors. Only the left rScO2 increased significantly upon the release of both retractors. Following the correction of the neck position, bilateral rScO2 increased significantly in both groups (p < 0.001). CONCLUSION: The rScO2 of the left carotid artery was shown to significantly decrease due to the indirect impact of the retractors. After extending the head and neck, bilateral rScO2 values decreased significantly in both groups. However, despite this decline, there was no significant decrease in brain perfusion that would result in ischemia. The absence of a statistically significant distinction between the groups implies that it is unlikely to have an impact on brain perfusion.


Assuntos
Vértebras Cervicais , Discotomia , Oximetria , Acidente Vascular Cerebral , Humanos , Discotomia/métodos , Discotomia/efeitos adversos , Feminino , Masculino , Pessoa de Meia-Idade , Vértebras Cervicais/cirurgia , Adulto , Oximetria/métodos , Acidente Vascular Cerebral/etiologia , Estudos Prospectivos , Saturação de Oxigênio/fisiologia , Encéfalo/cirurgia
7.
J Glaucoma ; 33(10): 728-734, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39133058

RESUMO

PRCIS: Increased oxygen saturation (StO 2 ) was significantly associated with the severity of visual field (VF) damage in patients with glaucoma. OBJECTIVE: To investigate the association between retinal StO 2 percentage and the severity of VF loss in glaucoma. METHODS: A total of 198 eyes from 131 patients with glaucoma were included in this cross-sectional study. Participants underwent imaging using ocular oximetry (Zilia) and 24-2 Swedish Interactive Threshold Algorithm standard VF (Carl Zeiss-Meditec). StO 2 (%) was measured at 2 locations of the peripapillary optic nerve head (superotemporal, and inferotemporal). Measurements were reported as the mean of at least 5 measurements in each location. Associations between the severity of VF loss, reported as mean deviation, and StO 2 (%) were calculated. RESULTS: A total of 198 eyes of 131 patients (mean (95% CI) age, 71.1 (68.9,73.3) years, 68 females (51.9%), and 63 males (48.1%) were analyzed. In univariable analysis, higher StO 2 -0.06 (-0.12, 0.00) was associated with severity in all hemifields ( P = 0.047). Multivariate regression analysis showed that each 1% increase in StO 2 was associated with -0.06 (-0.12, -0.00) dB loss in mean deviation in all hemifields ( P = 0.043). In multivariate regression analysis in the superior hemifields, higher StO 2 -0.07 (-0.16, 0.01) tended to be associated with superior hemifield severity ( P = 0.09). CONCLUSIONS: Retinal oximetry enabled the continuous quantitative measurement of retinal StO 2. Increased StO 2 was significantly associated with the severity of VF damage in patients with glaucoma.


Assuntos
Pressão Intraocular , Oximetria , Saturação de Oxigênio , Transtornos da Visão , Testes de Campo Visual , Campos Visuais , Humanos , Masculino , Feminino , Campos Visuais/fisiologia , Estudos Transversais , Idoso , Pressão Intraocular/fisiologia , Saturação de Oxigênio/fisiologia , Transtornos da Visão/fisiopatologia , Transtornos da Visão/diagnóstico , Oxigênio/metabolismo , Oxigênio/sangue , Pessoa de Meia-Idade , Disco Óptico/metabolismo , Retina/fisiopatologia , Retina/metabolismo , Retina/diagnóstico por imagem , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/metabolismo , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma/fisiopatologia , Glaucoma/metabolismo , Glaucoma/diagnóstico , Índice de Gravidade de Doença
8.
Eur J Pediatr ; 183(10): 4425-4433, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39126518

RESUMO

Fidgety movements provide early information about a potential development of cerebral palsy in preterm neonates. The aim was to assess differences in the combined outcome of mortality and fidgety movements defined as normal or pathological in very preterm neonates according to the group allocation in the randomised-controlled multicentre COSGOD III trial. Preterm neonates of two centres participating in the COSGOD III trial, whose fidgety movements were assessed as normal or pathological at six to 20 weeks of corrected age, were analysed. In the COSGOD III trial cerebral oxygen saturation (crSO2) was measured by near-infrared spectroscopy (NIRS) during postnatal transition and guided resuscitation in preterm neonates randomised to the NIRS-group, whereby medical support was according routine, as it was also in the control group. Fidgety movements were classified in normal or abnormal/absent at six to 20 weeks of corrected age. Mortality and fidgety movements of preterm neonates allocated to the NIRS-group were compared to the control-group. Normal outcome was defined as survival with normal fidgety movements. One-hundred-seventy-one preterm neonates were included (NIRS-group n = 82; control-group n = 89) with a median gestational age of 29.4 (27.4-30.4) and 28.7 (26.7-31.0) weeks in the NIRS-group and the control-group, respectively. There were no differences in the combined outcome between the two groups: 90.2% of the neonates in the NIRS-group and 89.9% in the control-group survived with normal outcome (relative risk [95% CI]; 0.96 [0.31-2.62]).Conclusions: In the present cohort of preterm neonates, monitoring of crSO2 and dedicated interventions in addition to routine care during transition period after birth did not show an impact on mortality and fidgety movements defined as normal or pathological at six to 20 weeks corrected age. What is Known • Fidgety movements display early spontaneous motoric pattern and may provide early information about a potential development of cerebral palsy in preterm neonates.  What is New  â€¢ This retrospective observational study of the randomised-controlled multicentre COSGOD III trial is the first study investigating the potential influence of cerebral oxygenation guided resuscitation during postnatal transition period on combined outcome of mortality and fidgety movements up to 20 weeks of corrected age in very preterm neonates. • This study adds to the growing interest of assessing cerebral oxygenation, that monitoring of cerebral oxygen saturation and dedicated interventions during postnatal transition period according to the COSGOD III trial has no significant influence on mortality and fidgety movements defined as normal or pathological in very preterm neonates.


Assuntos
Paralisia Cerebral , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Recém-Nascido , Feminino , Masculino , Saturação de Oxigênio/fisiologia , Idade Gestacional , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Movimento/fisiologia , Encéfalo/metabolismo , Circulação Cerebrovascular/fisiologia
9.
Intensive Care Med ; 50(9): 1470-1483, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39162827

RESUMO

PURPOSE: Patients receiving venoarterial extracorporeal membrane oxygenation (VA-ECMO) frequently develop arterial hyperoxaemia, which may be harmful. However, lower oxygen saturation targets may also lead to harmful episodes of hypoxaemia. METHODS: In this registry-embedded, multicentre trial, we randomly assigned adult patients receiving VA-ECMO in an intensive care unit (ICU) to either a conservative (target SaO2 92-96%) or to a liberal oxygen strategy (target SaO2 97-100%) through controlled oxygen administration via the ventilator and ECMO gas blender. The primary outcome was the number of ICU-free days to day 28. Secondary outcomes included ICU-free days to day 60, mortality, ECMO and ventilation duration, ICU and hospital lengths of stay, and functional outcomes at 6 months. RESULTS: From September 2019 through June 2023, 934 patients who received VA-ECMO were reported to the EXCEL registry, of whom 300 (192 cardiogenic shock, 108 refractory cardiac arrest) were recruited. We randomised 149 to a conservative and 151 to a liberal oxygen strategy. The median number of ICU-free days to day 28 was similar in both groups (conservative: 0 days [interquartile range (IQR) 0-13.7] versus liberal: 0 days [IQR 0-13.7], median treatment effect: 0 days [95% confidence interval (CI) - 3.1 to 3.1]). Mortality at day 28 (59/159 [39.6%] vs 59/151 [39.1%]) and at day 60 (64/149 [43%] vs 62/151 [41.1%] were similar in conservative and liberal groups, as were all other secondary outcomes and adverse events. The conservative group experienced 44 (29.5%) major protocol deviations compared to 2 (1.3%) in the liberal oxygen group (P < 0.001). CONCLUSIONS: In adults receiving VA-ECMO in ICU, a conservative compared to a liberal oxygen strategy, did not affect the number of ICU-free days to day 28.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Unidades de Terapia Intensiva/estatística & dados numéricos , Saturação de Oxigênio/fisiologia , Sistema de Registros/estatística & dados numéricos , Oxigênio , Choque Cardiogênico/terapia , Choque Cardiogênico/mortalidade , Parada Cardíaca/terapia , Parada Cardíaca/mortalidade
10.
Medicine (Baltimore) ; 103(31): e39031, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39093729

RESUMO

BACKGROUND: This study aimed to compare the acute effects of aerobic exercise performed with blood flow restriction (BFR), a novel method to increase exercise gains, with blood free flow (BFF) conditions in type 2 diabetes mellitus (T2DM). METHODS: Fifteen individuals with T2DM performed BFF and BFR (40% of arterial occlusion pressure) cycling exercises 48 hours apart, at equal intensity (45% heart rate reserve) and duration (38 minutes). Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), blood glucose, heart rate, and muscle oxygen saturation (SmO2) were assessed before-after and during exercise sessions. RESULTS: SBP, DBP, and MAP in the overload phase were higher in the BFR group than in the BFF group (P = .009, 0.031, and 0.013, respectively). Changes in blood pressure (∆SBP and ∆DBP) were similar between the BFF and BFR groups (P > .05), whereas ∆MAP differed (P = .016). Changes in blood glucose levels and heart rates were not significantly different between the groups. Although SmO2baseline was lower in the BFR group (P = .049), SmO2min and SmO2max did not differ significantly between the BFF and BFR groups. CONCLUSION: The similar decrease in blood glucose levels between the groups suggests that BFR exercise is favorable in terms of hypoglycemia. The higher blood pressure observed during the BFR exercise remained within safe limits. These results suggest that people with T2DM can safely perform BFR aerobic exercises; however, further studies are required.


Assuntos
Glicemia , Pressão Sanguínea , Diabetes Mellitus Tipo 2 , Exercício Físico , Frequência Cardíaca , Humanos , Diabetes Mellitus Tipo 2/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Exercício Físico/fisiologia , Glicemia/análise , Glicemia/metabolismo , Fluxo Sanguíneo Regional/fisiologia , Idoso , Saturação de Oxigênio/fisiologia , Terapia por Exercício/métodos , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/fisiopatologia
11.
J Biomed Opt ; 29(8): 086004, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39139703

RESUMO

Significance: The multispectral imaging-based tissue oxygen saturation detecting (TOSD) system offers deeper penetration ( ∼ 2 to 3 mm) and comprehensive tissue oxygen saturation ( StO 2 ) assessment and recognizes the wound healing phase at a low cost and computational requirement. The potential for miniaturization and integration of TOSD into telemedicine platforms could revolutionize wound care in the challenging pandemic era. Aim: We aim to validate TOSD's application in detecting StO 2 by comparing it with wound closure rates and laser speckle contrast imaging (LSCI), demonstrating TOSD's ability to recognize the wound healing process. Approach: Utilizing a murine model, we compared TOSD with digital photography and LSCI for comprehensive wound observation in five mice with 6-mm back wounds. Sequential biochemical analysis of wound discharge was investigated for the translational relevance of TOSD. Results: TOSD demonstrated constant signals on unwounded skin with differential changes on open wounds. Compared with LSCI, TOSD provides indicative recognition of the proliferative phase during wound healing, with a higher correlation coefficient to wound closure rate (TOSD: 0.58; LSCI: 0.44). StO 2 detected by TOSD was further correlated with proliferative phase angiogenesis markers. Conclusions: Our findings suggest TOSD's enhanced utility in wound management protocols, evaluating clinical staging and therapeutic outcomes. By offering a noncontact, convenient monitoring tool, TOSD can be applied to telemedicine, aiming to advance wound care and regeneration, potentially improving patient outcomes and reducing healthcare costs associated with chronic wounds.


Assuntos
Saturação de Oxigênio , Cicatrização , Cicatrização/fisiologia , Animais , Camundongos , Saturação de Oxigênio/fisiologia , Oxigênio/metabolismo , Pele/diagnóstico por imagem , Pele/irrigação sanguínea , Pele/metabolismo , Masculino
12.
J Biomed Opt ; 29(Suppl 3): S33305, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39139814

RESUMO

Significance: Questions about the accuracy of pulse oximeters in measuring arterial oxygen saturation ( SpO 2 ) in individuals with darker skin pigmentation have resurfaced since the COVID-19 pandemic. This requires investigation to improve patient safety, clinical decision making, and research. Aim: We aim to use computational modeling to identify the potential causes of inaccuracy in SpO 2 measurement in individuals with dark skin and suggest practical solutions to minimize bias. Approach: An in silico model of the human finger was developed to explore how changing melanin concentration and arterial oxygen saturation ( SaO 2 ) affect pulse oximeter calibration algorithms using the Monte Carlo (MC) technique. The model generates calibration curves for Fitzpatrick skin types I, IV, and VI and an SaO 2 range between 70% and 100% in transmittance mode. SpO 2 was derived by inputting the computed ratio of ratios for light and dark skin into a widely used calibration algorithm equation to calculate bias ( SpO 2 - SaO 2 ). These were validated against an experimental study to suggest the validity of the Monte Carlo model. Further work included applying different multiplication factors to adjust the moderate and dark skin calibration curves relative to light skin. Results: Moderate and dark skin calibration curve equations were different from light skin, suggesting that a single algorithm may not be suitable for all skin types due to the varying behavior of light in different epidermal melanin concentrations, especially at 660 nm. The ratio between the mean bias in White and Black subjects in the cohort study was 6.6 and 5.47 for light and dark skin, respectively, from the Monte Carlo model. A linear multiplication factor of 1.23 and exponential factor of 1.8 were applied to moderate and dark skin calibration curves, resulting in similar alignment. Conclusions: This study underpins the careful re-assessment of pulse oximeter designs to minimize bias in SpO 2 measurements across diverse populations.


Assuntos
Melaninas , Método de Monte Carlo , Oximetria , Pigmentação da Pele , Humanos , Oximetria/métodos , Melaninas/análise , Pigmentação da Pele/fisiologia , Algoritmos , Simulação por Computador , Saturação de Oxigênio/fisiologia , Calibragem , COVID-19 , Oxigênio/sangue , Oxigênio/metabolismo , SARS-CoV-2 , Luz , Pele/química , Pele/irrigação sanguínea , Dedos/irrigação sanguínea , Dedos/fisiologia
14.
Sci Rep ; 14(1): 19117, 2024 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-39155284

RESUMO

Accurate assessment of vital parameters is essential for diagnosis and triage of critically ill patients, but not always feasible in out-of-hospital settings due to the lack of suitable devices. We performed an extensive validation of a novel prototype in-ear device, which was proposed for the non-invasive, combined measurement of core body temperature (Tc), oxygen saturation (SpO2), and heart rate (HR) in harsh environments. A pilot study with randomized controlled design was conducted in the terraXcube environmental chamber. Participants were subsequently exposed to three 15 min test sessions at the controlled ambient temperatures of 20 °C, 5 °C, and - 10 °C, in randomized order. Vital parameters measured by the prototype were compared with Tc measurements from commercial esophageal (reference) and tympanic (comparator) probes and SpO2 and HR measurements from a finger pulse-oximeter (reference). Performance was assessed in terms of bias and Lin's correlation coefficient (CCC) with respect to the reference measurements and analyzed with linear mixed models. Twenty-three participants (12 men, mean (SD) age, 35 (9) years) completed the experimental protocol. The mean Tc bias of the prototype ranged between - 0.39 and - 0.80 °C at ambient temperatures of 20 °C and 5 °C, and it reached - 1.38 °C only after 15 min of exposure to - 10 °C. CCC values ranged between 0.07 and 0.25. SpO2 and HR monitoring was feasible, although malfunctioning was observed in one third of the tests. SpO2 and HR bias did not show any significant dependence on environmental conditions, with values ranging from - 1.71 to - 0.52% for SpO2 and 1.12 bpm to 5.30 bpm for HR. High CCC values between 0.81 and 0.97 were observed for HR in all environmental conditions. This novel prototype device for measuring vital parameters in cold environments demonstrated reliability of Tc measurements and feasibility of SpO2 and HR monitoring. Through non-invasive and accurate monitoring of vital parameters from the ear canal our prototype may offer support in triage and treatment of critically ill patients in harsh out-of-hospital conditions.


Assuntos
Temperatura Corporal , Frequência Cardíaca , Humanos , Masculino , Feminino , Adulto , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Projetos Piloto , Oximetria/instrumentação , Oximetria/métodos , Saturação de Oxigênio/fisiologia , Pessoa de Meia-Idade , Temperatura
15.
J Biomed Opt ; 29(Suppl 3): S33309, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39170819

RESUMO

Significance: Monitoring oxygen saturation ( SpO 2 ) is important in healthcare, especially for diagnosing and managing pulmonary diseases. Non-contact approaches broaden the potential applications of SpO 2 measurement by better hygiene, comfort, and capability for long-term monitoring. However, existing studies often encounter challenges such as lower signal-to-noise ratios and stringent environmental conditions. Aim: We aim to develop and validate a contactless SpO 2 measurement approach using 3D convolutional neural networks (3D CNN) and 3D visible-near-infrared (VIS-NIR) multimodal imaging, to offer a convenient, accurate, and robust alternative for SpO 2 monitoring. Approach: We propose an approach that utilizes a 3D VIS-NIR multimodal camera system to capture facial videos, in which SpO 2 is estimated through 3D CNN by simultaneously extracting spatial and temporal features. Our approach includes registration of multimodal images, tracking of the 3D region of interest, spatial and temporal preprocessing, and 3D CNN-based feature extraction and SpO 2 regression. Results: In a breath-holding experiment involving 23 healthy participants, we obtained multimodal video data with reference SpO 2 values ranging from 80% to 99% measured by pulse oximeter on the fingertip. The approach achieved a mean absolute error (MAE) of 2.31% and a Pearson correlation coefficient of 0.64 in the experiment, demonstrating good agreement with traditional pulse oximetry. The discrepancy of estimated SpO 2 values was within 3% of the reference SpO 2 for ∼ 80 % of all 1-s time points. Besides, in clinical trials involving patients with sleep apnea syndrome, our approach demonstrated robust performance, with an MAE of less than 2% in SpO 2 estimations compared to gold-standard polysomnography. Conclusions: The proposed approach offers a promising alternative for non-contact oxygen saturation measurement with good sensitivity to desaturation, showing potential for applications in clinical settings.


Assuntos
Imageamento Tridimensional , Imagem Multimodal , Redes Neurais de Computação , Oximetria , Humanos , Oximetria/métodos , Imagem Multimodal/métodos , Adulto , Masculino , Imageamento Tridimensional/métodos , Feminino , Saturação de Oxigênio/fisiologia , Adulto Jovem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Face/diagnóstico por imagem , Face/irrigação sanguínea , Oxigênio/sangue
16.
Comput Biol Med ; 180: 108911, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39089111

RESUMO

Patients with surgical, pulmonary, and cardiac problems, continual monitoring of Oxygen Saturation of a Person (SpO2) and Respiratory Rate (RR) is essential. Similarly, the persons with cardiopulmonary health issues, RR estimation is crucial. The performance of the ventilator assistance and lung medicines are evaluated using SpO2 and RR. For the persons, those who are living alone with respiratory illnesses need a compulsory estimation of RR. In case of serious illness, the RR might face abrupt changes. The immobility of the disturbance and RR makes the RR evaluation from the PhotoPlethysmoGraphic (PPG) signals is a difficult challenge. So, an efficient RR and SpO2 estimation framework from the PPG signal using the deep learning method is developed in this paper. At first, the PPG signal is collected from standard data sources. The collected PPG signals undergo signal pre-processing. The pre-processing procedures include Motion Artifacts (MA) removal and filtering techniques. The pre-processed signals are split into distinct windows. From the split windows of the signals, the spectral features, RR, and Respiratory Peak Variance (RPV) features are extracted. The retrieved features are selected optimally with the help of Advanced Golden Tortoise Beetle Optimizer (AGTBO). The weights are chosen optimally with the same AGTBO. The optimally selected features are fused with the optimal features to get the weighted optimal features. These weighted optimal features are fed into the Ensemble Learning-based RR and SpO2 Estimation Network (ELRR-SpO2EN). The ensemble learning model is developed by combining Multilayer Perceptron (MLP), AdaBoost, and Attention-based Long Short Term Memory (A-LSTM). The performance of the developed RR and SpO2 estimation model is compared with other existing techniques. The experimental analysis results revealed that the proposed AGTBO-ELRR-SpO2EN model attained 96 % accuracy for the second dataset, which is higher than the conventional models such as MLP (90 %), Adaboost (92 %), A-LSTM (92 %), and MLP-ADA-ALSTM (94 %). Thus, it has been confirmed that the designed RR and SpO2 estimation framework from PPG signals is more efficient than the other conventional models.


Assuntos
Saturação de Oxigênio , Fotopletismografia , Processamento de Sinais Assistido por Computador , Fotopletismografia/métodos , Humanos , Saturação de Oxigênio/fisiologia , Artefatos , Taxa Respiratória/fisiologia , Masculino , Oxigênio/sangue , Oxigênio/metabolismo
17.
J Biomed Opt ; 29(Suppl 3): S33308, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39211937

RESUMO

Significance: Our goal is to understand the root cause of reported oxygen saturation ( SpO 2 ) overestimation in heavily pigmented skin types to devise solutions toward enabling equity in pulse oximeter designs. Aim: We aim to gain theoretical insights into the effect of skin tone on SpO 2 - R curves using a three-dimensional, four-layer tissue model representing a finger. Approach: A finger tissue model, comprising the epidermis, dermis, two arteries, and a bone, was developed using a Monte Carlo-based approach in the MCmatlab software. Two skin tones-light and dark-were simulated by adjusting the absorption and scattering properties within the epidermal layer. Following this, SpO 2 - R curves were generated in various tissue configurations, including transmission and reflection modes using red and infrared wavelengths. In addition, the influence of source-detector (SD) separation distances on both light and dark skin tissue models was studied. Results: In transmission mode, SpO 2 - R curves did not deviate with changes in skin tones because both pulsatile and non-pulsatile terms experienced equal attenuation at red and infrared wavelengths. However, in reflection mode, measurable variations in SpO 2 - R curves were evident. This was due to differential attenuation of the red components, which resulted in a lower perfusion index at the red wavelength in darker skin. As the SD separation increased, the effect of skin tone on SpO 2 - R curves in reflection mode became less pronounced, with the largest SD separation exhibiting effects similar to those observed in transmission mode. Conclusions: Monte Carlo simulations have demonstrated that different light pathlengths within the tissue contribute to the overestimation of SpO 2 in people with darker skin in reflection mode pulse oximetry. Increasing the SD separation may mitigate the effect of skin tone on SpO 2 readings. These trends were not observed in transmission mode; however, further planned research using more complex models of the tissue is essential.


Assuntos
Método de Monte Carlo , Oximetria , Saturação de Oxigênio , Pigmentação da Pele , Humanos , Pigmentação da Pele/fisiologia , Oximetria/métodos , Saturação de Oxigênio/fisiologia , Oxigênio/sangue , Simulação por Computador , Pele/irrigação sanguínea , Pele/química , Pele/diagnóstico por imagem , Modelos Biológicos , Dedos/fisiologia , Dedos/irrigação sanguínea
18.
J Transl Med ; 22(1): 732, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39103816

RESUMO

BACKGROUND: Inspiratory muscle fatigue has been shown to have effects on limbs blood flow and physical performance. This study aimed to evaluate the influence of an inspiratory muscle fatigue protocol on respiratory muscle strength, vertical jump performance and muscle oxygen saturation in healthy youths. METHODS: A randomized and double-blinded controlled clinical trial, was conducted. Twenty-four participants aged 18-45 years, non-smokers and engaged in sports activity at least three times a week for a minimum of one year were enrolled in this investigation. Participants were randomly assigned to three groups: Inspiratory Muscle Fatigue (IMFG), Activation, and Control. Measurements of vertical jump, diaphragmatic ultrasound, muscle oxygen saturation, and maximum inspiratory pressure were taken at two stages: before the intervention (T1) and immediately after treatment (T2). RESULTS: The IMFG showed lower scores in muscle oxygen saturation and cardiorespiratory variables after undergoing the diaphragmatic fatigue intervention compared to the activation and control groups (p < 0.05). For the vertical jump variables, intragroup differences were found (p < 0.01), but no differences were shown between the three groups (p > 0.05). CONCLUSIONS: Inspiratory muscle fatigue appears to negatively impact vertical jump performance, muscle oxygen saturation and inspiratory muscle strength in healthy youths. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT06271876. Date of registration 02/21/2024. https://clinicaltrials.gov/study/NCT06271876 .


Assuntos
Inalação , Fadiga Muscular , Força Muscular , Músculos Respiratórios , Humanos , Músculos Respiratórios/fisiologia , Fadiga Muscular/fisiologia , Força Muscular/fisiologia , Masculino , Adolescente , Adulto Jovem , Feminino , Adulto , Inalação/fisiologia , Saturação de Oxigênio/fisiologia , Pessoa de Meia-Idade , Diafragma/fisiologia , Método Duplo-Cego
19.
Scand J Med Sci Sports ; 34(8): e14709, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39132736

RESUMO

We explored the impact of running in the severe intensity domain on running mechanics and muscle oxygenation in competitive runners by investigating the relationship between mechanical deviations from typical stride characteristics and muscle oxygen saturation (SmO2) in the quadriceps muscle. Sixteen youth competitive runners performed an 8-min exhaustive running test on an outdoor track. Running mechanics were continuously monitored using inertial measurement units. Rectus femoris SmO2 and total hemoglobin (a measure of blood volume) were continuously monitored by near-infrared spectroscopy. One-class support vector machine (OCSVM) modeling was employed for subject-specific analysis of the kinematic data. Statistical analysis included principal component analysis, ANOVA, and correlation analysis. Mechanical deviations from typical stride characteristics increased as the running test progressed. Specifically, the percentage of outliers in the OCSVM model rose gradually from 2.2 ± 0.8% at the start to 43.6 ± 28.2% at the end (p < 0.001, mean ± SD throughout). SmO2 dropped from 74.3 ± 8.4% at baseline to 10.1 ± 6.8% at the end (p < 0.001). A moderate negative correlation (r = -0.61, p = 0.013) was found between the average SmO2 and the percentage of outlier strides during the last 15% of the run. During high-intensity running, alterations in running biomechanics may occur, linked to decreased quadriceps muscle oxygenation. These parameters highlight the potential of using running kinematics and muscle oxygenation in training to optimize performance and reduce injury risks. Our research contributes to understanding biomechanical and physiological responses to endurance running and emphasizes the importance of individualized monitoring.


Assuntos
Músculo Quadríceps , Corrida , Humanos , Corrida/fisiologia , Masculino , Fenômenos Biomecânicos , Adolescente , Músculo Quadríceps/fisiologia , Músculo Quadríceps/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho , Feminino , Consumo de Oxigênio/fisiologia , Saturação de Oxigênio/fisiologia , Oxigênio/metabolismo , Oxigênio/sangue , Marcha/fisiologia
20.
Sensors (Basel) ; 24(16)2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39204858

RESUMO

The aim of this work was to validate the measurements of three physiological parameters, namely, body temperature, heart rate, and peripheral oxygen saturation, captured with an out-of-the-lab device using measurements taken with clinically proven devices. The out-of-the-lab specialized device was integrated into a customized mHealth application, e-CoVig, developed within the AIM Health project. To perform the analysis, single consecutive measurements of the three vital parameters obtained with e-CoVig and with the standard devices from patients in an intensive care unit were collected, preprocessed, and then analyzed through classical agreement analysis, where we used Lin's concordance coefficient to assess the agreement correlation and Bland-Altman plots with exact confidence intervals for the limits of agreement to analyze the paired data readings. The existence of possible systematic errors was also addressed, where we found the presence of additive errors, which were corrected, and weak proportional biases. We obtained the mean overall agreement between the measurements taken with the novel e-CoVig device and the reference devices for the measured quantities. Although some limitations in this study were encountered, we present more advanced methods for their further assessment.


Assuntos
Temperatura Corporal , Frequência Cardíaca , Telemedicina , Humanos , Telemedicina/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Frequência Cardíaca/fisiologia , Temperatura Corporal/fisiologia , Saturação de Oxigênio/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA