Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arch Anim Nutr ; 78(1): 95-107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38567675

RESUMO

The aim was to determine ileal endogenous nitrogen losses (ENL) and true ileal N-digestibility (TD-N) under non-steady-state conditions of the 15N-isotope dilution technique (15N-IDT), using diets generating low and high ENL and compare results to those obtained under steady-state conditions. Twelve growing pigs (mean LW 22.4 kg) fitted with a post-valve T-caecum cannula were fed an enzyme-hydrolysed casein (EHC)-based diet or an EHC diet + 4% quebracho tannins (QT) and were labelled via continuous 15N-leucine i.v. infusion or twice daily oral 15N-leucine administration. Digesta were collected daily over three consecutive hours with blood plasma sampled on the four consecutive days after cessation of 15N-labelling. There was a significant effect of sampling day on the dilution factor. Endogenous N losses were significantly lower for the EHC than the EHC+QT diet (2.41 vs. 8.69 g/kg DMI), while no significant effect of sampling day was observed. The TD-N of the EHC+QT diet did not differ from the TD-N of the EHC diet (95.1 vs. 92.0%). A significant effect of sampling day was observed for TD-N with day 1 and 2, being higher than day 4. Non-steady-state conditions overestimated ENL by 25-28% as compared to 3 h collections in steady-state conditions, but the relative overestimation was similar for the EHC diet as for the EHC+QT diet. TD-N did not differ significantly compared to 12 h steady-state measurements, but comparison to 3 h steady-state measurements showed that non-steady-state conditions overestimated TD-N for the EHC+QT diet by 9%. However, on day 4 this overestimation disappeared. Using the 15N-IDT during non-steady-state conditions can provide valuable additional data on endogenous N losses and TD-N.


Assuntos
Ração Animal , Dieta , Digestão , Íleo , Isótopos de Nitrogênio , Nitrogênio , Animais , Íleo/fisiologia , Íleo/metabolismo , Nitrogênio/metabolismo , Digestão/efeitos dos fármacos , Digestão/fisiologia , Dieta/veterinária , Ração Animal/análise , Fenômenos Fisiológicos da Nutrição Animal , Masculino , Sus scrofa/fisiologia , Técnicas de Diluição do Indicador/veterinária , Suínos/fisiologia , Feminino
2.
Vet Clin Pathol ; 50(3): 369-375, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34322896

RESUMO

BACKGROUND: To date, little information is available about the effect of preanalytical factors on the urinary protein-to-creatinine (UPC) ratio in cats. OBJECTIVES: We aimed to evaluate the effect of a commercially available cat litter, creatinine measurements at three different dilutions of urine, and different storage conditions on the UPC ratio in cats. METHODS: Feline urine specimens were prospectively collected. Twenty-two whole-urine specimens were placed uncovered and in contact with cat litter for 1 hour; 25 urine supernatants were diluted 1:10, 1:20, and 1:100 for creatinine measurements. The correlation, difference, agreement, and concordance in classifying specimens according to International Renal Interest Society staging were determined. Storage effects on UPC ratios were assessed in specimens stored for 6 hours at +20℃ (n = 20), 1 week at +4℃ (n = 20), and 3 months at -20℃ (n = 25). Specimens were also subjected to four freeze-thaw cycles (n = 20). Results were compared, and clinical significance was assessed by comparing each UPC ratio to the inter-assay range of the baseline value. RESULTS: Exposure to cat litter did not affect UPC ratios. A positive proportional bias was found in the 1:100 dilution compared with the 1:20 dilution; however, concordance was high for all comparisons. At +20, +4℃, and after four repeated freeze-thaw cycles, UPC ratios were stable. Compared with baseline values, UPC ratios decreased (P < .01) after 8 and 12 weeks at -20℃. However, all UPC ratios were within the inter-assay variability of the baseline value. CONCLUSIONS: Exposure to cat litter did not affect UPC ratios, but further studies are necessary to evaluate other potential variables. The effects of the dilutions and storage conditions were clinically acceptable, although the 1:20 and 1:100 dilutions were not perfectly comparable.


Assuntos
Doenças do Gato , Proteinúria , Animais , Gatos , Creatinina , Técnicas de Diluição do Indicador/veterinária , Rim , Proteinúria/veterinária
3.
Animal ; 15(3): 100156, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33573950

RESUMO

The ability to accurately estimate fat mass and fat-free mass (FFM) has the potential to improve the way in which sow body condition can be managed in a breeding herd. Bioelectrical impedance spectroscopy (BIS) has been evaluated as a practical technique for assessment of body composition in several livestock species, but similar work is lacking in sows. Bioelectrical impedance uses population-specific algorithms that require values for the apparent resistivities of body fluids and body proportion factors. This study comprised three major aims: (i) to derive apparent resistivity coefficients for extracellular water (ECW) and intracellular water (ICW) required for validation of BIS predictions of total body water (TBW) in live sows against standard reference tracer dilution methods; (ii) to develop predictions of TBW to body composition prediction algorithms, namely FFM, by developing a body geometry correction factor (Kb) and (iii) to compare the BIS predictions of FFM against existing impedance predictors and published prediction equations for use in sows, based on physical measurements of back-fat depth and BW (P2-based predictors). Whole body impedance measurements and the determination of TBW by deuterium dilution and ECW by bromide dilution were performed on 40 Large White x Landrace sows. Mean apparent resistivity coefficients of body fluids were 431.1 Ω.cm for ECW and 1827.8 Ω.cm for ICW. Using these coefficients, TBW and ECW were over-estimated by 6.5 and 3.3%, respectively, compared to measured reference values, although these differences were not statistically different (P > 0.05). Mean Kb was 1.09 ±â€¯0.14. Fat-free mass predictions were 194.9 kg, which equates to 60.9% of total sow weight, and 183.0 kg for BIS and the deuterium dilution method, respectively. Mean differences between the predicted and measured FFM values ranged from -8.2 to 32.7%, but were not statistically different (P > 0.05). Method validation (leave-one-out procedure) revealed that mean differences between predicted and measured values were not statistically significant (P > 0.05). Of the impedance-based predictors, equivalence testing revealed that BIS displayed the lowest test bias of 11.9 kg (8.2%), although the P2-based prediction equations exhibited the lowest bias and percentage equivalence, with narrow limits of agreement. Results indicate although differences between mean predicted and measured values were not significantly different, relatively wide limits of agreement suggest BIS as an impractical option for assessing body composition in individual sows compared to the use of existing prediction equations based on BW and back fat.


Assuntos
Composição Corporal , Água Corporal , Animais , Impedância Elétrica , Feminino , Técnicas de Diluição do Indicador/veterinária , Análise Espectral/veterinária , Suínos
4.
J Vet Emerg Crit Care (San Antonio) ; 30(4): 498-500, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32588953

RESUMO

BACKGROUND: Cardiac output, stroke volume, and measurement of other hemodynamic parameters can be useful in the management of critical patients. Given the broad size disparity of veterinary patients, the raw values can vary widely. Their indexed values, however, allow for quick assessment of hemodynamic status and a more standardized target setting by the veterinary care team. Monitors such as lithium dilution cardiac output (LiDCO) and pulse contour cardiac output (PICCO) can display and record the data using indexed values as long as the correct body surface area (BSA) is used. In people, the BSA is calculated using the DuBois formula by entering the patient's weight and height; however, it does not apply to animals because the equivalent relationship is not represented by this formula. Given that the hemodynamic monitors are manufactured for use in human patients, the calculations need to the adapted for veterinary use. As such, the Dubois formula has been rearranged to calculate an assumed height to be entered in the monitor software along with the patient's weight. Once the information is entered, a correct BSA will be calculated by the monitor, and indexed data will be readily available for analysis. KEY FINDINGS: Tables with the calculated heights for dogs and cats were generated. The weights and calculated heights were computed into the LiDCO and PICCO monitors for verification, and the correct BSAs were displayed as a result. SIGNIFICANCE: The information supplied here allows clinicians and researchers to quickly input patient data into the hemodynamic monitor and obtain indexed data. Indexed data facilitates advanced hemodynamic monitoring by standardizing targets (goal-directed therapy) and allowing for quicker comparison between patients. The table could be used with any monitor that utilizes the DuBois formula for BSA calculation, but the resulting BSA should be validated before proceeding with hemodynamic monitoring.


Assuntos
Superfície Corporal/veterinária , Gatos/anatomia & histologia , Gatos/fisiologia , Cães/anatomia & histologia , Cães/fisiologia , Monitorização Fisiológica/veterinária , Animais , Humanos , Técnicas de Diluição do Indicador/veterinária , Monitorização Fisiológica/métodos
5.
Arq. bras. med. vet. zootec. (Online) ; 72(3): 729-736, May-June, 2020. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1128889

RESUMO

This study investigated in vitro the efficacy of four different extenders (TES-TRIS and TRIS with LDL low-density lipoprotein at concentrations of 10 or 5%) on the longevity of buffalo sperm in the refrigeration process at 5ºC. Sperm motility was assessed every 24 hours up to 72 hours of incubation using computer assisted sperm analysis and sperm membrane integrity was examined by the hypoosmotic test (HOST) at T1, T24, T48 and T72 hours. Eleven buffaloes (1 ejaculate per buffalo) of the Murrah breed were used, ranging in age from 4 to 5 years. Immediately after collection, each ejaculate was fractionated into 4 aliquots, and each aliquot was diluted in one of four diluents to obtain 50x106SPTZ/mL. The samples were packed in 0.5mL straws and refrigerated (-0.25°C/min) to 5°C and maintained at this temperature until evaluation. Prior to evaluation the samples were heated at 37°C for 30 seconds. The statistical package used for analysis was STATA 12.0 "Statistical Analysis Software" and means were compared by the Friedman test (P<0.05). The results of sperm kinetics and HOST indicate that the TRIS diluent with 10% LDL could be a promising alternative for semen refrigeration at 5ºC, to be used in conventional and fixed time artificial insemination.(AU)


Este estudo investigou in vitro a eficácia de quatro diferentes extensores (TES-TRIS e TRIS com lipoproteína de baixa densidade - LDL, nas concentrações de 10 ou 5%) sobre a longevidade espermática de búfalos no processo de refrigeração a 5ºC. A motilidade espermática foi avaliada a cada 24 horas até 72 horas de incubação, por sistema computadorizado "CASA", e a integridade de membrana espermática foi examinada pelo teste hiposmótico (HOST) em T1, T24, T48 e T72 horas. Foram utilizados 11 búfalos (um ejaculado por búfalo) da raça Murrah, com idade variando de quatro a cinco anos. Imediatamente após a coleta, cada ejaculado foi fracionado em quatro alíquotas, e cada alíquota foi diluída em um dos quatro diluidores para a obtenção de 50x106 SPTZ/mL. As amostras foram envasadas em palhetas de 0,5 mL, refrigeradas (-0,25oC/minuto) até 5oC e mantidas nessa temperatura até a avaliação. Previamente à avaliação, as amostras foram aquecidas a 37oC por 30 segundos. O pacote estatístico utilizado para as análises foi o STATA 12.0 "Statistical Analysis Software", e as médias foram comparadas pelo teste de Friedman (P<0,05). Os resultados de cinética e HOST até o tempo de 48 horas indicam que o diluidor TRIS com 10% LDL seria uma alternativa promissora para a refrigeração do sêmen a 5ºC, a ser utilizado na inseminação artificial e na inseminação artificial em tempo fixo.(AU)


Assuntos
Animais , Masculino , Preservação do Sêmen/veterinária , Motilidade dos Espermatozoides , Búfalos , Lipoproteínas LDL , Técnicas In Vitro , Inseminação Artificial , Técnicas de Diluição do Indicador/veterinária
6.
J Anim Sci ; 95(10): 4344-4351, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29108049

RESUMO

Body condition score and percent body fat (BF; %) of horses are positively correlated with reproductive efficiency and are indicative of metabolic issues. However, BF in horses may be poorly predicted because current procedures are either subjective or dependent on one anatomical location. Therefore, the objectives of the current study were to compare 2 methods of predicting BF using rump fat thickness (RFT) and deuterium oxide (DO) dilution with actual tissue fat analysis by near-infrared spectroscopy (NIRS) in stock-type horses and to identify the relationship between BF and BCS. Twenty-four stock-type horses were selected to be humanely euthanized based on 3 primary criteria: geriatric, crippled, and/or unsafe. Approximately 20 h before slaughter, horses were weighed and BCS assessed to be 1 ( = 1; 433 kg), 2 ( = 1; 415 kg), 3 ( = 1; 376 kg), 4 ( = 7; 468 ± 13 kg), 5 ( = 10; 455 ± 11 kg), and 6 ( = 4; 493 ± 12 kg) and RFT was measured using ultrasonography. Blood samples were collected immediately before and 4 h after DO infusion (0.12 g/kg BW). Deuterium oxide concentration of plasma was determined by gas isotope ratio mass spectrometry. Horses were housed in a dry lot overnight before being individually sedated (1.1 mg xylazine/kg BW) and anesthetized using a jugular venipuncture (2.2 mg ketamine/kg BW), and potassium chloride (KCl) solution was administered to cease cardiac function before exsanguination. After euthanasia, horse carcasses were processed and dissected and tissues were collected for NIRS analysis. Body fat predicted by DO dilution was correlated with BF measured by NIRS analysis on various weight bases ( = 0.76 to 0.81, < 0.001), whereas no correlation was observed for BF predicted by RFT. A paired -test indicated that both DO dilution and RFT overestimated BF by 2.48 to 3.26% ( < 0.001) and 5.81 to 6.59% ( < 0.001), respectively, compared with NIRS analysis. Body condition scores affected BF measured by NIRS analysis ( ≤ 0.038) and predicted by DO dilution ( < 0.001) and RFT ( = 0.042). The current study provided evidence that DO dilution was a better prediction method for BF than RFT and that BCS may serve as a BF predictor in stock-type horses.


Assuntos
Tecido Adiposo/fisiologia , Composição Corporal/fisiologia , Cavalos/fisiologia , Técnicas de Diluição do Indicador/veterinária , Reprodução/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/veterinária , Animais , Peso Corporal/fisiologia , Óxido de Deutério , Espectrometria de Massas/veterinária
7.
J Anim Sci ; 95(5): 2041-2051, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28727018

RESUMO

Body fatness and degree of body fat mobilization in cows vary enormously during their reproduction cycle and influence energy partitioning and metabolic adaptation. The objective of the study was to test bioelectrical impedance spectroscopy (BIS) as a method for predicting fat depot mass (FDM), in living cows. The FDM is defined as the sum of subcutaneous, omental, mesenteric, retroperitoneal, and carcass fat mass. Bioelectrical impedance spectroscopy is compared with the prediction of FDM from the deuterium oxide (DO) dilution method and from body conformation measurements. Charolais × Holstein Friesian (HF; = 18; 30 d in milk) crossbred cows and 2 HF (lactating and nonlactating) cows were assessed by body conformation measurements, BIS, and the DO dilution method. The BCS of cows was a mean of 3.68 (SE 0.64). For the DO dilution method, a bolus of 0.23 g/kg BW DO (60 atom%) was intravenously injected and deuterium (D) enrichment was analyzed in plasma and whey by stabile isotope mass spectrometry, and total body water content was calculated. Impedance measurement was performed using a 4-electrode interface and time domain-based measurement system consisting of a voltage/current converter for applying current stimulus and an amplifier for monitoring voltage across the sensor electrodes. For the BIS, we used complex impedances over three frequency decades that delivers information on intra- and extracellular water and capacity of cell membranes. Impedance data (resistance of extra- and intracellular space, cell membrane capacity, and phase angle) were extracted 1) by simple curve fit to extract the resistance at direct current and high frequency and 2) by using an electrical equivalent circuit. Cows were slaughtered 7 d after BIS and D enrichment measurements and dissected for the measurement of FDM. Multiple linear regression analyses were performed to predict FDM based on data obtained from body conformation measurements, BIS, and D enrichment, and applied methods were evaluated by cross-validation. The FDM varied widely between cows and was correlated to D enrichment in plasma ( = 0.91, < 0.05). Prediction of FDM by body size measurements was less precise ( = 0.84), but FDM prediction was more accurate using D enrichment in plasma ( = 0.90) and BIS ( = 0.99) data. Therefore, both BIS and D enrichment analysis resulted in similarly good predictions of FDM in cows, and we conclude that BIS could have the potential to predict FDM in dairy cows from 40 to 380 kg.


Assuntos
Tecido Adiposo/metabolismo , Bovinos/metabolismo , Espectroscopia Dielétrica/métodos , Leite/química , Animais , Composição Corporal , Pesos e Medidas Corporais , Deutério/análise , Deutério/metabolismo , Óxido de Deutério , Impedância Elétrica , Feminino , Técnicas de Diluição do Indicador/veterinária , Lactação , Técnica de Diluição de Radioisótopos/veterinária , Água/análise
8.
J Anim Sci ; 94(12): 5122-5128, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28046185

RESUMO

The objectives of the present study were to design a method to estimate mammary plasma flow (MPF) in lactating sows using downstream dilution of -aminohippuric acid (AH) and to compare these estimates with MPF estimates based on specific AA as internal markers (MPF-AA). A permanent indwelling catheter was surgically implanted in the femoral artery, and another 2 were inserted in the right cranial mammary vein of 8 second- and third-parity sows on d 76 ± 2 SEM of gestation. On the 3rd and 17th days in milk, arterial and venous blood samples were drawn in hourly intervals from 0.5 h before until 6.5 h after feeding. The MPF in the right cranial mammary vein was measured by downstream dilution of infused AH (3.0 mmol/h). Total MPF-AH was calculated assuming that the measured flow constituted the flow from 5 out of 14 suckled glands on the basis of the anatomical structure of the mammary vascular system. Total MPF-AA was estimated on the basis of the output of the specific AA marker in milk and the arteriovenous differences of the marker as free AA in plasma, assuming a direct transfer of AA from plasma to milk protein. Total MPF-AH was 6,860 L/d in early lactation and increased to 8,953 L/d at peak lactation ( = 0.003). In early lactation, MPF-AA estimates were greater or tended to be greater (132% to 175%; < 0.10) than MPF-AH estimates for all internal markers, except Met (119%). Moreover, MPF-AH was correlated with MPF-AA only for MET as an internal marker ( = 0.74; = 0.03) in early lactation. In contrast, MPF-AH and MPF-AA estimates did not differ and were well correlated at peak lactation with the strongest correlation observed when Met ( = 0.84; = 0.009) and Phe + Tyr ( = 0.82; = 0.01) were used as the internal AA markers. Litter gain increased from d 3 to 17 of lactation (2.13 vs. 3.46 g/d; = 0.001) and was correlated with MPF-AH during lactation ( = 0.74; < 0.001), whereas no correlation between litter gain and MPF-AA was observed ( > 0.10). These results suggest that downstream dilution of infused AH and the AA methods are applicable methods to estimate MPF at peak lactation. The reason for the observed discrepancy in early lactation between MPF- AH and MPF-AA is not obvious but might be related to the rapid metabolic changes observed in early lactation. In conclusion, MPF measured by downstream dilution of mammary infused AH was higher at peak compared to early lactation, which the internal AA marker approach failed to show.


Assuntos
Lactação/fisiologia , Glândulas Mamárias Animais/fisiologia , Suínos/fisiologia , Animais , Feminino , Técnicas de Diluição do Indicador/veterinária , Glândulas Mamárias Animais/irrigação sanguínea , Leite/química , Proteínas do Leite/análise , Gravidez , Ácido p-Aminoipúrico
9.
Am J Vet Res ; 76(6): 547-53, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26000602

RESUMO

OBJECTIVE: To develop equations for prediction of total body water (TBW) content in unsedated dogs by combining impedance (resistance and reactance) and morphological variables and to compare the results of those equations with TBW content determined by deuterium dilution (TBW(d)). ANIMALS: 26 healthy adult Beagles. PROCEDURES: TBW content was determined directly by deuterium dilution and indirectly with equations developed from measurements obtained by use of a portable bioelectric impedance device and morphological variables including body length, height, weight, and thoracic and abdominal circumferences. RESULTS: Impedance and morphological data from 16 of the 26 dogs were used to determine coefficients for the following 2 equations: TBW(1) = -0.019 (BL(2)/R) + -0.199 (RC + AC) + 0.996 W + 0.081 H + 12.31; and TBW(2) = 0.048 (BL(2)/R) + -0.144 (RC + AC) + 0.777 W + 0.066 H + 0.031 X + 7.47, where AC is abdominal circumference, H is height, BL is body length, R is resistance, RC is rib cage circumference, W is body weight, and × is reactance. Results for TBW(1) (R(2)(1) = 0.843) and TBW(2) (R(2)(2) = 0.816) were highly correlated with the TBW(d). When the equations were validated with data from the remaining 10 dogs, the respective mean differences between TBW(d) and TBW(1) and TBW(2) were 0.17 and 0.11 L, which equated to a nonsignificant underestimation of TBW content by 2.4% and 1.6%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that impedance and morphological data can be used to accurately estimate TBW content in adult Beagles. This method of estimating TBW content is less expensive and easier to perform than is measurement of TBW(d), making it appealing for daily use in veterinary practice.


Assuntos
Antropometria/métodos , Composição Corporal , Água Corporal/metabolismo , Cães/fisiologia , Impedância Elétrica , Animais , Peso Corporal , Deutério/metabolismo , Feminino , Técnicas de Diluição do Indicador/veterinária , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
10.
J Anim Sci ; 92(12): 5507-19, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25367518

RESUMO

The aims of the present study were to quantify colostrum intake (CI) of piglets using the D2O dilution technique, to develop a mechanistic model to predict CI, to compare these data with CI predicted by a previous empirical predictive model developed for bottle-fed piglets, and to study how composition of diets fed to gestating sows affected piglet CI, sow colostrum yield (CY), and colostrum composition. In total, 240 piglets from 40 litters were enriched with D2O. The CI measured by D2O from birth until 24 h after the birth of first-born piglet was on average 443 g (SD 151). Based on measured CI, a mechanistic model to predict CI was developed using piglet characteristics (24-h weight gain [WG; g], BW at birth [BWB; kg], and duration of CI [D; min]: CI, g=-106+2.26 WG+200 BWB+0.111 D-1,414 WG/D+0.0182 WG/BWB (R2=0.944). This model was used to predict the CI for all colostrum suckling piglets within the 40 litters (n=500, mean=437 g, SD=153 g) and was compared with the CI predicted by a previous empirical predictive model (mean=305 g, SD=140 g). The previous empirical model underestimated the CI by 30% compared with that obtained by the new mechanistic model. The sows were fed 1 of 4 gestation diets (n=10 per diet) based on different fiber sources (low fiber [17%] or potato pulp, pectin residue, or sugarbeet pulp [32 to 40%]) from mating until d 108 of gestation. From d 108 of gestation until parturition, sows were fed 1 of 5 prefarrowing diets (n=8 per diet) varying in supplemented fat (3% animal fat, 8% coconut oil, 8% sunflower oil, 8% fish oil, or 4% fish oil+4% octanoic acid). Sows fed diets with pectin residue or sugarbeet pulp during gestation produced colostrum with lower protein, fat, DM, and energy concentrations and higher lactose concentrations, and their piglets had greater CI as compared with sows fed potato pulp or the low-fiber diet (P<0.05), and sows fed pectin residue had a greater CY than potato pulp-fed sows (P<0.05). Prefarrowing diets affected neither CI nor CY, but the prefarrowing diet with coconut oil decreased lactose and increased DM concentrations of colostrum compared with other prefarrowing diets (P<0.05). In conclusion, the new mechanistic predictive model for CI suggests that the previous empirical predictive model underestimates CI of sow-reared piglets by 30%. It was also concluded that nutrition of sows during gestation affected CY and colostrum composition.


Assuntos
Ração Animal/análise , Fenômenos Fisiológicos da Nutrição Animal , Animais Recém-Nascidos/fisiologia , Colostro/química , Dieta/veterinária , Sus scrofa/fisiologia , Animais , Líquidos Corporais , Óleo de Coco , Óxido de Deutério/sangue , Óxido de Deutério/química , Fibras na Dieta/administração & dosagem , Suplementos Nutricionais , Feminino , Óleos de Peixe/metabolismo , Técnicas de Diluição do Indicador/veterinária , Modelos Lineares , Estado Nutricional/fisiologia , Óleos de Plantas , Gravidez , Óleo de Girassol , Suínos , Aumento de Peso/fisiologia
11.
Am J Vet Res ; 75(6): 565-71, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24866512

RESUMO

OBJECTIVE: To assess the accuracy of an ultrasound velocity dilution cardiac output (UDCO) method, compared with that of the lithium dilution cardiac output (LiDCO) method, for determination of cardiac output (CO) in juvenile horses with experimentally induced hypovolemia. ANIMALS: 12 anesthetized 2- to 6-month-old horses. PROCEDURES: For each anesthetized horse, CO was determined by the LiDCO and UDCO methods prior to any intervention (baseline state), after withdrawal of approximately 40% of the horse's blood volume (low CO state), after maintenance of hypovolemia and infusion of norepinephrine until mean arterial blood pressure was equal to baseline value (high CO state), and after further infusion of norepinephrine and back-transfusion of withdrawn blood (posttransfusion state). For each of the 4 hemodynamic situations, CO and calculated cardiac index (CI) values were obtained by each method in duplicate (8 pairs of measurements/horse); mean values for each horse and overall mean values across all horses were calculated. Agreement between CI determined by each method (96 paired values) was assessed by Bland-Altman analysis. RESULTS: For the UDCO method-derived CI measurements among the 12 horses, mean ± SD bias was -4 ± 11.3 mL/kg/min (95% limits of agreement, -26.1 to 18.2 mL/kg/min) and mean relative bias was -10.4 ± 21.5% (95% limits of agreement, -52.6% to 31.8%). CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that, compared with the LiDCO method, the UDCO method has acceptable clinical usefulness for determination of CO in foals.


Assuntos
Débito Cardíaco/fisiologia , Testes de Função Cardíaca/veterinária , Hipovolemia/diagnóstico por imagem , Hipovolemia/fisiopatologia , Ultrassom/métodos , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Velocidade do Fluxo Sanguíneo/veterinária , Volume Sanguíneo/fisiologia , Volume Sanguíneo/veterinária , Testes de Função Cardíaca/métodos , Cavalos , Técnicas de Diluição do Indicador/veterinária , Lítio/sangue , Norepinefrina , Ultrassonografia
12.
Br J Anaesth ; 112(2): 367-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23996857

RESUMO

BACKGROUND: In a previous in vitro study using saline medium, the authors showed that certain drugs changed the voltages of lithium dilution cardiac output (LiDCO) sensors and also influenced their accuracy in measuring lithium concentrations. These two parameters correlated and so we examined whether such drug-sensor interaction exists when LiDCO sensor was exposed to xylazine in blood. METHODS: Five healthy adult warm-blood horses were injected with 0.5 mg kg(-1) xylazine i.v. Physiological saline solution and venous blood were consecutively sampled through the same LiDCO sensor at 60, 45, 30, 15, and 0 min before and then 5, 15, 30, 45, and 60 min after xylazine injection. Sensor voltages were recorded and the differences between saline- and blood-exposed sensor voltages were compared at each time point. RESULTS: Saline-exposed sensor voltages continuously increased in a non-linear pattern during the experiment. Blood-exposed sensor voltages also increased in a similar pattern, but it was interrupted by an abrupt increase in voltage after xylazine injection. The differences between saline- and blood-exposed sensor voltages were 7 (6.1-8) mV [median (range)] before xylazine but decreased significantly at 5 and 15 min after xylazine treatment. The highest drug-induced voltage change was 3.4 (1.6-7) mV. CONCLUSIONS: This study showed that exposure of a LiDCO sensor to blood after a single clinically relevant dose of xylazine in horses changed the voltages of the sensors for 15 min. Comparison of saline- and blood-exposed sensor voltages could become a tool to detect drug-sensor interactions.


Assuntos
Analgésicos/farmacologia , Débito Cardíaco/efeitos dos fármacos , Eletrodos Seletivos de Íons/veterinária , Cloreto de Lítio , Xilazina/farmacologia , Analgésicos/sangue , Animais , Débito Cardíaco/fisiologia , Feminino , Cavalos , Técnicas de Diluição do Indicador/veterinária , Cloreto de Lítio/sangue , Masculino , Reprodutibilidade dos Testes , Cloreto de Sódio , Termodiluição/métodos , Termodiluição/veterinária , Xilazina/sangue
13.
BMC Vet Res ; 9: 216, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-24144185

RESUMO

BACKGROUND: The purpose of this study was to objectively compare methodological approaches that might be utilized in designing an antimicrobial resistance (AMR) surveillance program in beef feedlot cattle. Specifically, four separate comparisons were made to investigate their potential impact on estimates for prevalence of AMR. These included investigating potential differences between 2 different susceptibility testing methods (broth microdilution and disc diffusion), between 2 different target bacteria (non-type-specific E. coli [NTSEC] and Mannheimia haemolytica), between 2 strategies for sampling feces (individual samples collected per rectum and pooled samples collected from the pen floor), and between 2 strategies for determining which cattle to sample (cattle that were culture-positive for Mannheimia haemolytica and those that were culture-negative). RESULTS: Comparing two susceptibility testing methods demonstrated differences in the likelihood of detecting resistance between automated disk diffusion (BioMIC®) and broth microdilution (Sensititre®) for both E. coli and M. haemolytica. Differences were also detected when comparing resistance between two bacterial organisms within the same cattle; there was a higher likelihood of detecting resistance in E. coli than in M. haemolytica. Differences in resistance prevalence were not detected when using individual animal or composite pen sampling strategies. No differences in resistance prevalences were detected in E. coli recovered from cattle that were culture-positive for M. haemolytica compared to those that were culture-negative, suggesting that sampling strategies which targeted recovery of E. coli from M. haemolytica-positive cattle would not provide biased results. CONCLUSIONS: We found that for general purposes, the susceptibility test selected for AMR surveillance must be carefully chosen considering the purpose of the surveillance since the ability to detect resistance appears to vary between these tests depending upon the population where they are applied. Continued surveillance of AMR in M. haemolytica recovered by nasopharyngeal swab is recommended if monitoring an animal health pathogen is an objective of the surveillance program as results of surveillance using fecal E. coli cannot be extrapolated to this important respiratory pathogen. If surveillance of E. coli was pursued in the same population, study populations could target animals that were culture-positive for M. haemolytica without biasing estimates for AMR in E. coli. Composite pen-floor sampling or sampling of individuals per-rectum could possibly be used interchangeably for monitoring resistance in E. coli.


Assuntos
Doenças dos Bovinos/tratamento farmacológico , Farmacorresistência Bacteriana , Testes de Sensibilidade Microbiana/veterinária , Animais , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Bovinos/microbiologia , Doenças dos Bovinos/epidemiologia , Doenças dos Bovinos/microbiologia , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/métodos , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/veterinária , Escherichia coli/efeitos dos fármacos , Infecções por Escherichia coli/tratamento farmacológico , Infecções por Escherichia coli/microbiologia , Infecções por Escherichia coli/veterinária , Técnicas de Diluição do Indicador/veterinária , Mannheimia haemolytica/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Infecções por Pasteurellaceae/tratamento farmacológico , Infecções por Pasteurellaceae/microbiologia , Infecções por Pasteurellaceae/veterinária , Prevalência
14.
J Dairy Sci ; 96(3): 1815-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23332845

RESUMO

Despite the fact that llamas have become increasingly popular as companion and farm animals in both Europe and North America, scientific knowledge on their nutrient requirements is scarce. Compared with other livestock species, relatively little is known especially about the nutrient and energy requirements for lactating llamas. Therefore, we aimed to measure milk output in llama dams using an isotope dilution technique and relate it to energy intakes at different stages of lactation. We also validated the dilution technique by measuring total water turnover (TWT) directly and comparing it with values estimated by the isotope dilution technique. Our study involved 5 lactating llama dams and their suckling young. Milk output and TWT were measured at 4 stages of lactation (wk 3, 10, 18, and 26 postpartum). The method involved the application of the stable hydrogen isotope deuterium ((2)H) to the lactating dam. Drinking water intake and TWT decreased significantly with lactation stage, whether estimated by the isotope dilution technique or calculated from drinking water and water ingested from feeds. In contrast, lactation stage had no effect on dry matter intake, metabolizable energy (ME) intake, or the milk water fraction (i.e., the ratio between milk water excreted and TWT). The ratios between TWT measured and TWT estimated (by isotope dilution) did not differ with lactation stage and were close to 100% in all measurement weeks, indicating that the D(2)O dilution technique estimated TWT with high accuracy and only small variations. Calculating the required ME intakes for lactation from milk output data and gross energy content of milk revealed that, with increasing lactation stage, ME requirements per day for lactation decreased but remained constant per kilogram of milk output. Total measured ME intakes at different stages of lactation were similar to calculated ME intakes from published recommendation models for llamas.


Assuntos
Camelídeos Americanos/fisiologia , Lactação/fisiologia , Animais , Animais Lactentes/metabolismo , Camelídeos Americanos/metabolismo , Ingestão de Energia/fisiologia , Feminino , Técnicas de Diluição do Indicador/veterinária , Lactação/metabolismo , Água/metabolismo
15.
Br J Anaesth ; 109(6): 870-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22907338

RESUMO

BACKGROUND: Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated the influence of lung injury on the accuracy and precision of CO measurement using TPUD in an animal model. METHODS: In nine neonatal lambs, central venous and arterial catheters were inserted and connected to the TPUD monitor. Repeated lavages with warmed isotonic saline were performed to gradually induce lung injury. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe around the main pulmonary artery (COufp). An increase in oxygenation index was used as an indicator of induced lung injury during the experiment. Post-mortem lung injury was confirmed by histopathological examination. RESULTS: Fifty-five sessions of three paired CO measurements were analysed. The mean COufp was 1.53 litre min(-1) (range 0.66-2.35 litre min(-1)), and the mean COtpud was 1.65 litre min(-1) (range 0.78-2.91 litre min(-1)). The mean bias (standard deviation) between the two methods was 0.13 (0.15) litre min(-1) with limits of agreement of ±0.29 litre min(-1). The overall percentage error was 19.1%. The accuracy and precision did not change significantly during progressive lung injury. Histopathological severity scores were consistent with heterogeneous lung injury. The capability to track changes in CO using TPUD was moderate to good. CONCLUSIONS: The accuracy and precision of CO measurement using TPUD is not influenced in the presence of heterogeneous lung injury in an animal model.


Assuntos
Débito Cardíaco , Lesão Pulmonar/veterinária , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária , Ultrassonografia/veterinária , Animais , Animais Recém-Nascidos , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/veterinária , Cateterismo Periférico/instrumentação , Cateterismo Periférico/veterinária , Modelos Animais de Doenças , Técnicas de Diluição do Indicador/instrumentação , Técnicas de Diluição do Indicador/veterinária , Lesão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Carneiro Doméstico , Ultrassonografia/instrumentação
16.
Br J Anaesth ; 109(6): 864-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22926200

RESUMO

BACKGROUND: This study compares cardiac output (CO) measurements obtained by lithium dilution (LiDCO), pulse power analysis (PulseCO), and continuous thermodilution (CTD) with bolus thermodilution (BTD) in ponies. METHODS: Eight isoflurane-anaesthetized Shetland ponies received xylazine, ketamine, and midazolam infusions (0.3, 1.2, and 0.018 mg kg(-1) h(-1), respectively). CO was measured with BTD, CTD, LiDCO, and PulseCO. Lithium was injected into the jugular vein and blood was sampled from the facial artery for lithium detection and this artery was also used for PulseCO. Measurements were obtained during four stable haemodynamic conditions in the following order: isoflurane 1% (end-tidal concentration), isoflurane 2%, isoflurane 1%, and isoflurane 1%+dobutamine 5 µg kg(-1) min(-1). RESULTS: The bias (2 sd) was 2.5 (2.1) and 0.5 (2.9) litre min(-1) for LiDCO-BTD and for CTD-BTD comparisons, respectively. The limits of agreement were wider than ±30%; therefore, interchangeability was rejected for both comparisons. A possible error in LiDCO might explain the bias observed because CTD-BTD comparison showed less bias. Changes in PulseCO did not correlate with those of BTD and a weak correlation (r(2)=0.23; P=0.018) and concordance (Pc=0.42) was found between CTD and BTD. CONCLUSIONS: This is the first study to show a large bias for LiDCO-BTD comparison in animals receiving xylazine, ketamine, and midazolam infusions. The trending abilities of neither PulseCO nor CTD were reliable. Further studies are needed to elucidate possible influences of drugs on the accuracy of the LiDCOplus system.


Assuntos
Anestesia/veterinária , Pressão Sanguínea/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Cloreto de Lítio , Monitorização Fisiológica/métodos , Análise de Onda de Pulso/métodos , Analgésicos/farmacologia , Anestesia/métodos , Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/farmacologia , Animais , Cardiotônicos/farmacologia , Dobutamina/farmacologia , Feminino , Cavalos , Técnicas de Diluição do Indicador/veterinária , Isoflurano/farmacologia , Ketamina/farmacologia , Cloreto de Lítio/sangue , Masculino , Midazolam/farmacologia , Monitorização Fisiológica/veterinária , Reprodutibilidade dos Testes , Termodiluição/métodos , Termodiluição/veterinária , Xilazina/farmacologia
17.
J Vet Emerg Crit Care (San Antonio) ; 21(4): 328-34, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21827590

RESUMO

OBJECTIVE: To compare the determination of cardiac output (CO) via arterial pulse pressure waveform analysis (FloTrac/Vigileo) versus lithium dilution method. DESIGN: Prospective study. SETTING: University teaching hospital. ANIMALS: Six adult dogs. INTERVENTIONS: Dogs were instrumented for CO determinations using lithium dilution (LiDCO) and FloTrac/Vigileo methods. Direct blood pressure, heart rate, arterial blood gases, and end-tidal isoflurane (ETIso) and CO(2) concentrations were measured throughout the study while CO was manipulated with different depth of anesthesia and rapid administration of isotonic crystalloids at 60 mL/kg/h. MEASUREMENTS AND MAIN RESULTS: Baseline CO measurements were obtained at 1.3% ETIso and were lowered by 3% ETIso. Measurements were obtained in duplicate or triplicate with LiDCO and averaged for comparison with corresponding values measured continuously with the FloTrac/Vigileo method. For 30 comparisons between methods, a mean bias of -100 mL/kg/min and 95% limits of agreement between -311 and +112 mL/kg/min (212 mL/kg/min) was determined. The mean (mL/kg/min) of the differences of LiDCO-Vigileo=62.0402+-0.8383 × Vigileo, and the correlation coefficient (r) between the 2 methods 0.70 for all CO determinations. The repeatability coefficients for the individual LiDCO and FloTrac/Vigileo methods were 187 and 400 mL/kg/min, respectively. Mean LiDCO and FloTrac/Vigileo values from all measurements were 145 ± 68 mL/kg/min (range, 64-354) and 244 ± 144 mL/kg/min (range, 89-624), respectively. The overall mean relative error was 48 ± 14%. CONCLUSION: The FloTrac/Vigileo overestimated CO values compared with LiDCO and the relative error was high, which makes this method unreliable for use in dogs.


Assuntos
Anestesia/veterinária , Débito Cardíaco/fisiologia , Cães/fisiologia , Testes de Função Cardíaca/veterinária , Cloreto de Lítio/metabolismo , Animais , Pressão Sanguínea , Feminino , Testes de Função Cardíaca/métodos , Técnicas de Diluição do Indicador/veterinária , Masculino , Estudos Prospectivos
18.
J Vet Emerg Crit Care (San Antonio) ; 21(4): 321-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21827589

RESUMO

OBJECTIVE: To determine if metatarsal artery pressure (COmet) is comparable to femoral artery pressure (COfem) as the input for transpulmonary pulse contour analysis (PiCCO) in anesthetized dogs, using the lithium dilution method (LiDCO) as a standard for cardiac output (CO) measurement. DESIGN: Prospective randomized study. SETTING: University research laboratory. ANIMALS: Ten healthy purpose-bred mixed breed dogs were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO. INTERVENTIONS: The CO was measured using LiDCO and PiCCO techniques. Animals had their right femoral and left distal metatarsal artery catheterized for proximal (COfem) and distal (COmet) PiCCO analysis, respectively. Measurements were obtained from each animal during low, normal, and high CO states by changing amount of inhalant anesthetics and heart rate. Measurements were converted to CO indexed to body weigh (CI(BW) =CO/kg) for statistical analysis. Agreement was determined using Bland and Altman analysis and concordance correlation coefficients. MEASUREMENTS AND MAIN RESULTS: Thirty paired measurements were taken. The LiDCO CI(BW) (± SD) was 68.7 ± 30.3, 176.0 ± 53.0, and 211.1 ± 76.5 mL/kg/min during low, normal, and high CO states, respectively. There was a significant effect of CI(BW) state on bias and relative bias with COmet (P<0.001 and P=0.003, respectively). Bias of the COmet method (± SD) was -116.6 (70.5), 20.1(76.4), and 91.3 (92.0) mL/kg/min at low, normal, and high CI(BW), respectively. Bias of the COfem (± SD) was -20.3 (19.0), 8.6 (70.9), and -2.9 (83.0) mL/kg/min at low, normal, and high CI(BW) , respectively. The mean relative bias for COfem was -6.7 ± 44% (limits of agreements: -81.2 to 67.9%). CONCLUSION: Compared with lithium dilution, the pulse contour analysis provides a good estimation of CO, but requires femoral artery catheterization in anesthetized dogs.


Assuntos
Débito Cardíaco/fisiologia , Cães/fisiologia , Testes de Função Cardíaca/veterinária , Monitorização Fisiológica/veterinária , Animais , Artérias , Pressão Sanguínea , Artéria Femoral , Testes de Função Cardíaca/métodos , Técnicas de Diluição do Indicador/veterinária , Metatarso/irrigação sanguínea , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos
19.
Vet Anaesth Analg ; 38(4): 279-85, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21627753

RESUMO

OBJECTIVE: The purpose of this study was to compare CO measured by use of lithium dilution (LiDCO) and ultrasound velocity dilution (UDCO) in a canine model of acute hemorrhage. STUDY DESIGN: Prospective descriptive evaluation. ANIMALS: Twelve dogs (15-34 kg). METHODS: Dogs were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases and CO. The CO was measured by use of LiDCO and UDCO techniques. Measurements were obtained from each animal at baseline and during a low CO state (hemorrhagic state). Measurements were converted to cardiac index (CI = CO/BSA) values for statistical analysis. To measure CO using UDCO, a 20 mL bolus of 0.9% sodium chloride was administered and CO was calculated from the transient dilution of blood proteins created by the injection bolus. Hypovolemia was induced by withdrawing 40% of the blood volume until the mean arterial blood pressure (MAP) was stable at 40 mmHg for 10 minutes. Agreement was determined using Bland & Altman analysis and concordance correlation coefficients. RESULTS: Twenty-four comparisons were made. Lithium determinations of CI ranged between 7.5 and 1.3 L minute(-1) m(-2), and the mean overall difference between the two methods was -0.40 L minute(-1) m(-2). The mean relative bias was -17 ± 21% (limits of agreements: -59% to 25%). There was no significant effect of state of CI on bias or relative bias (p = 0.24 and p = 0.10, respectively). The concordance correlation coefficient between LiDCO and UDCO as 0.88 (p < 0.0001). CONCLUSIONS: When compared to lithium dilution, the UDCO technique is a viable method for measuring cardiac output in a model of normovolemia and hypovolemia in dogs.


Assuntos
Volume Sanguíneo/veterinária , Débito Cardíaco , Cães/fisiologia , Hemorragia/veterinária , Hipovolemia/veterinária , Técnicas de Diluição do Indicador/veterinária , Cloreto de Lítio , Anestesia Geral/veterinária , Animais , Volume Sanguíneo/fisiologia , Estudos de Viabilidade , Hemorragia/fisiopatologia , Hipovolemia/diagnóstico por imagem , Hipovolemia/fisiopatologia , Estudos Prospectivos , Ultrassonografia
20.
Equine Vet J ; 43(5): 562-70, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21496088

RESUMO

REASONS FOR PERFORMING THE STUDY: Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. OBJECTIVES: To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. HYPOTHESIS: D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. METHODS: Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. RESULTS: D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). CONCLUSIONS AND POTENTIAL RELEVANCE: This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids.


Assuntos
Tecido Adiposo Branco/fisiologia , Composição Corporal/fisiologia , Óxido de Deutério , Cavalos/fisiologia , Técnicas de Diluição do Indicador/veterinária , Animais , Peso Corporal/fisiologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA