Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.171
Filtrar
1.
Sci Rep ; 14(1): 8732, 2024 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627567

RESUMEN

We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.


Asunto(s)
Cirugía Laser de Córnea , Miopía , Herida Quirúrgica , Humanos , Córnea/cirugía , Sustancia Propia/cirugía , Agudeza Visual , Estudios Retrospectivos , Estudios de Casos y Controles , Cirugía Laser de Córnea/efectos adversos , Láseres de Excímeros/uso terapéutico , Refracción Ocular , Miopía/cirugía , Herida Quirúrgica/cirugía
2.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593257

RESUMEN

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Asunto(s)
Astigmatismo , Humanos , Adulto Joven , Adulto , Estudios Prospectivos , Córnea , Pupila , Biometría , Topografía de la Córnea , Refracción Ocular
3.
J Refract Surg ; 40(4): e245-e252, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593261

RESUMEN

PURPOSE: To evaluate clinical outcomes and visual quality 12 months after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) performed with the Custom-Q algorithm for correction of myopia with or without astigmatism and compensate for age-related accommodation deficiency. METHODS: Patients who had Custom-Q FS-LASIK for myopia and myopic astigmatism with age-related accommodation deficiency were included in this retrospective study. Distance, intermediate, and near visual acuities, objective and subjective refractions, Q-factor, corneal higher order aberrations (HOAs), accommodation function, defocus curve, contrast sensitivity, and a subjective questionnaire assessing visual quality were evaluated 12 months postoperatively. RESULTS: Clinical data of 43 cases were analyzed. The mean age was 42.02 ± 1.85 years (range: 40 to 48 years). At the 12-month follow-up visit, there were 43 (100%), 42 (97%), and 33 (77%) patients who achieved a binocular uncorrected distance, intermediate, and near visual acuity, respectively, better than 20/20 separately. Defocus curves revealed better distance vision in the dominant eyes, and the nondominant eyes performed better at intermediate and near vergence (P < .001). The Q-value and corneal spherical aberration coefficient were more positive in the dominant eyes than those in the nondominant eyes (P < .001). The accommodative amplitude and relative accommodation improved binocularly (P < .001). The questionnaire demonstrated high patient satisfaction with near vision, and no one reported having severe visual disturbance. CONCLUSIONS: For myopic patients with age-related accommodation deficiency, the Custom-Q algorithm proved to be an effective way to achieve acceptable near vision without compromising distance vision. [J Refract Surg. 2024;40(4):e245-e252.].


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Humanos , Adulto , Estudios Retrospectivos , Agudeza Visual , Córnea , Miopía/cirugía , Astigmatismo/cirugía , Láseres de Excímeros/uso terapéutico , Refracción Ocular , Resultado del Tratamiento
4.
BMC Ophthalmol ; 24(1): 145, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38561680

RESUMEN

BACKGROUND: The purpose of this study was to analyze myopic regression after corneal refractive surgery (CRS) in civilian pilots and to explore the factors that may cause long-term myopic regression. METHODS: We included civilian pilots who had undergone CRS to correct their myopia and who had at least 5 years of follow-up. We collected retrospective data and completed eye examinations and a questionnaire to assess their eye habits. RESULTS: A total of 236 eyes were evaluated in this study. 211 eyes had Intrastromal ablations (167 eyes had laser in situ keratomileusis, LASIK, 44 eyes had small incision lenticule extraction, SMILE) and 25 eyes had subepithelial ablations (15 eyes had laser epithelial keratomileusis, LASEK and 10 eyes had photorefractive keratectomy, PRK). The mean preoperative spherical equivalent (SE) was - 2.92 ± 1.11 D (range from - 1.00 to -5.00 D). A total of 56 eyes (23.6%) suffered from myopic regression after CRS. Comparisons of individual and eye characteristics between the regression and non-regression groups revealed statistically significant differences in age, cumulative flight time, postoperative SE (at 6 months and current), uncorrected visual acuity (UCVA), accommodative amplitude (AA), positive relative accommodation (PRA), postoperative period, types of CRS and eye habits. Generalized propensity score weighting (GPSW) was used to balance the distribution of covariates among different age levels, types of CRS, cumulative flying time, postoperative period and continuous near-work time. The results of GPS weighted logistic regression demonstrated that the associations between age and myopic regression, types of CRS and myopic regression, continuous near-work time and myopic regression were significant. Cumulative flying time and myopic regression, postoperative period and myopic regression were no significant. Specifically, the odds ratio (OR) for age was 1.151 (P = 0.022), and the OR for type of CRS was 2.769 (P < 0.001). The OR for continuous near-work time was 0.635 with a P value of 0.038. CONCLUSIONS: This is the first report to analyze myopic regression after CRS in civilian pilots. Our study found that for each year increase in age, the risk of civilian pilots experiencing myopic regression was increased. Intrastromal ablations had a lower risk of long-term myopia regression than subepithelial ablations. There is a higher risk of myopic progression with continuous near-work time > 45 min and poor accommodative function may be related factors in this specific population.


Asunto(s)
Queratomileusis por Láser In Situ , Miopía , Queratectomía Fotorrefractiva , Humanos , Lactante , Estudios Retrospectivos , Córnea/cirugía , Queratectomía Fotorrefractiva/métodos , Agudeza Visual , Refracción Ocular , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Resultado del Tratamiento
5.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600456

RESUMEN

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Miopía , Humanos , Refracción Ocular , Coma , Topografía de la Córnea , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Astigmatismo/cirugía , Sustancia Propia/cirugía
6.
Zhonghua Yan Ke Za Zhi ; 60(4): 330-336, 2024 Apr 11.
Artículo en Chino | MEDLINE | ID: mdl-38583056

RESUMEN

Objective: To investigate the influence of corneal e-value on the effectiveness of orthokeratology in controlling myopia in children and adolescents. Methods: A retrospective cohort study was conducted, involving the data from 1 563 myopic patients (1 563 eyes) who underwent orthokeratology at the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine from June 2015 to August 2021 and adhered to lens wear for at least 2 years. The cohort consisted of 737 males and 826 females with an average age of (10.84±2.13) years. Based on corneal e-value parameters obtained from corneal topography, patients were categorized into a low e-value group (n=425) and a high e-value group (n=1 138). Data on gender, age, parental myopia history, and baseline measures such as spherical equivalent (SE), axial length, and corneal e-value were collected. Differences in axial length change and corneal fluorescein staining rates were compared between the two groups at 1 and 2 years after the start of lens wear. A generalized linear mixed model was established with axial length change as the dependent variable to analyze the correlation between axial length change and baseline corneal e-value. Results: The initial age of the 1 563 myopic patients was (10.84±2.13) years, with a baseline SE of (-3.05±1.30) D. After 1 year of lens wear, the axial length change was (0.20±0.19) mm in the low e-value group and (0.24±0.20) mm in the high e-value group. After 2 years, the changes were (0.38±0.25) mm and (0.43±0.27) mm, respectively, with statistically significant differences (all P<0.05). The incidence of corneal staining after 1 year of lens wear was 9.2% (39/425) in the low e-value group and 14.1% (160/1 138) in the high e-value group. After 2 years, the rates were 15.8% (67/425) and 21.8% (248/1 138), respectively, with statistically significant differences (all P<0.05). After adjusting for parental myopia history, age, SE, and baseline axial length, the baseline corneal e-value was positively correlated with axial length change at 1 and 2 years after lens wear (all P<0.05). Conclusions: Corneal e-value is an independent factor influencing the effectiveness of orthokeratology in controlling myopia. A smaller corneal e-value is associated with slower axial length growth after orthokeratology, indicating better control of myopia in treated eyes.


Asunto(s)
Lentes de Contacto , Miopía , Procedimientos de Ortoqueratología , Masculino , Femenino , Niño , Humanos , Adolescente , Estudios Retrospectivos , Longitud Axial del Ojo , Miopía/terapia , Topografía de la Córnea , Refracción Ocular
7.
Int Ophthalmol ; 44(1): 153, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38509410

RESUMEN

PURPOSE: This study aimed to measure the Raman spectrum of the human corneal stroma lens obtained from small incision lenticule extraction surgery (SMILE) in Asian myopic eyes using a confocal Raman micro-spectrometer built in the laboratory. METHODS: Forty-three myopic patients who underwent SMILE with equivalent diopters between - 4.00 and - 6.00 D were selected, and the right eye data were collected. Corneal stroma lenses were obtained during surgery, and the Raman spectra were measured after air drying. The complete Raman spectrum of human myopic corneal stroma lens tissue was obtained within the range of 700-4000 cm-1. RESULTS: Thirteen characteristic peaks were found, with the stronger peaks appearing at 937 cm-1, corresponding to proline, valine, and the protein skeleton of the human myopic corneal stroma lens; 1243 cm-1, corresponding to collagen protein; 1448 cm-1, corresponding to the collagen protein and phospholipids; and 2940 cm-1, corresponding to the amino acid and lipids, which was the strongest Raman peak. CONCLUSION: These results demonstrated that Raman spectroscopy has much potential as a fast, cost-effective, and reliable diagnostic tool in the diagnosis and treatment of eye diseases, including myopia, keratoconus, and corneal infection.


Asunto(s)
Cirugía Laser de Córnea , Queratomileusis por Láser In Situ , Miopía , Humanos , Sustancia Propia/cirugía , Agudeza Visual , Miopía/diagnóstico , Miopía/cirugía , Queratomileusis por Láser In Situ/métodos , Colágeno , Láseres de Excímeros , Refracción Ocular
8.
J Cataract Refract Surg ; 50(4): 430-435, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38523280

RESUMEN

A 28-year-old nurse had an aberration-free femto-laser in situ keratomileusis (LASIK) performed for her myopia of -6.25 -0.50 × 096 and -6.75 -0.50 × 175 in the right and left eye, respectively. Corrected distance visual acuity (CDVA) preoperatively was 20/16. Preoperatively, there were no abnormalities on Scheimpflug imaging, and a pachymetry of 585 µm was measured in both eyes. Flap thickness was 115 µm. The patient was quite nervous during the surgery. Since the surgery, her uncorrected distance visual acuity (UDVA) and CDVA are suboptimal at 20/30 and 20/20 in the right eye, and 20/20 and 20/16 in the left eye. 3 months postoperatively, there is a stable manifest refraction of +0.25 -1.25 × 030 and +0.25 -0.00 × 0. The keratometric astigmatism in the Scheimpflug imaging is 1.2 diopter (D) × 114 and 0.4 D × 78 in the right and left eyes, respectively (FIgures 1 and 2). Thinnest pachymetry is 505 µm and 464 µm in the right and left eye, respectively. Her wavefront analysis shows refraction in a 6 mm zone of -0.99 -1.22 × 32 and -0.91 -0.36 × 136. The cycloplegic refraction is 1.25 -1.00 × 023 and +1.00 -0.25 × 006 (Figures 3 and 4). What is the cause of the suboptimal visual outcome in this case? What would be your treatment strategy to improve visual outcome?


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Humanos , Femenino , Adulto , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/cirugía , Resultado del Tratamiento , Agudeza Visual , Refracción Ocular , Miopía/cirugía , Miopía/complicaciones , Astigmatismo/cirugía , Astigmatismo/complicaciones , Láseres de Excímeros/uso terapéutico
9.
BMC Ophthalmol ; 24(1): 126, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38504225

RESUMEN

BACKGROUND: This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery. The aim is to assess how these formulas perform across different corneal curvature ranges, thereby guiding more precise IOL selection. METHODS: In this retrospective case series, 336 eyes from 336 patients who underwent cataract surgery were studied. The cohort was divided into three groups according to preoperative corneal power. Key metrics analyzed included mean prediction error (PE), standard deviation of PE (SD), mean absolute prediction error (MAE), median absolute error (MedAE), and the percentage of eyes with PE within ± 0.25 D, 0.50 D, ± 0.75 D, ± 1.00 D and ± 2.00 D. RESULTS: In the flat K group (Km < 43 D), VRF-G, Emmetropia Verifying Optical Version 2.0 (EVO2.0), Kane, and Hoffer QST demonstrated lower SDs (± 0.373D, ± 0.379D, ± 0.380D, ± 0.418D, respectively) compared to the VRF formula (all P < 0.05). EVO2.0 and K6 showed significantly different SDs compared to Barrett Universal II (BUII) (all P < 0.02). In the medium K group (43 D ≤ Km < 46 D), VRF-G, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS recorded lower MAEs (0.307D to 0.320D) than Olsen (OLCR) and Castrop (all P < 0.03), with RBF3.0 having the second lowest MAE (0.309D), significantly lower than VRF and Olsen (OLCR) (all P < 0.05). In the steep K group (Km ≥ 46D), RBF3.0, K6, and Kane achieved significantly lower MAEs (0.279D, 0.290D, 0.291D, respectively) than Castrop (all P < 0.001). CONCLUSIONS: The study highlights the varying accuracy of newer IOL formulas based on corneal power. VRF-G, EVO2.0, Kane, K6, and Hoffer QST are highly accurate for flat corneas, while VRF-G, RBF3.0, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS are recommended for medium K corneas. In steep corneas, RBF3.0, K6, and Kane show superior performance.


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Estudios Retrospectivos , Córnea , Ojo Artificial , Biometría , Refracción Ocular , Óptica y Fotónica , Longitud Axial del Ojo
10.
Ophthalmic Physiol Opt ; 44(3): 593-604, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38436461

RESUMEN

This study considered two questions associated with intraocular lens (IOL) power and refraction: (1) Given a refraction with a particular IOL in the eye, what will be the refraction for the IOL or another IOL if located differently with regard to tilt or anterior-posterior position? (2) For a target refraction, what is the power of another IOL if located differently with regard to tilt or position? A thin lens technique was developed to address these questions. For the first question, light was traced through the initial correcting spectacle lens to the cornea, refracted at the cornea, transferred to the position of the initial IOL, refracted at this IOL, transferred to the position of a new IOL (which may be the same IOL but with a different position and/or tilt), refracted backwards through the new IOL, transferred to the cornea and refracted out of the eye to give a new correcting spectacle lens power. For the second question, light was traced through the initial correcting spectacle lens to the cornea, refracted at the cornea, transferred to the position of the initial IOL, refracted at the initial IOL and transferred to the position of a new IOL. Light was also traced through the second correcting spectacle lens, refracted at the cornea and transferred to the position of the second IOL. The difference between the reduced image vergence for the first raytrace and the reduced object vergence for the second raytrace gave the effective power of the second IOL, and from this, the power of the second IOL was determined. Examples are presented for different situations, including a case report.


Asunto(s)
Cristalino , Lentes Intraoculares , Errores de Refracción , Humanos , Errores de Refracción/diagnóstico , Errores de Refracción/terapia , Refracción Ocular , Córnea
11.
BMC Ophthalmol ; 24(1): 143, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38549060

RESUMEN

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children. METHODS: This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ. RESULTS: The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05). CONCLUSION: The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.


Asunto(s)
Presbiopía , Refracción Ocular , Niño , Humanos , Femenino , Masculino , Preescolar , Adolescente , Pruebas de Visión , Córnea , Biometría , Longitud Axial del Ojo
12.
BMC Ophthalmol ; 24(1): 110, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454381

RESUMEN

BACKGROUND: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). METHODS: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ([Formula: see text]orientation), and was compared pre- and post-operative. RESULTS: Following SMILE, the magnitude of chord u[Formula: see text]) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). CONCLUSIONS: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.


Asunto(s)
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiología , Astigmatismo/cirugía , Refracción Ocular , Agudeza Visual , Pupila , Topografía de la Córnea
13.
Sci Rep ; 14(1): 5077, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38429419

RESUMEN

A novel model of human corneal birefringence is presented. The cornea is treated as a homogeneous biaxial linear birefringent medium in which the values of the binormal axes angle and organization of the main refractive indices vary continuously from the apex to the limbus. In its central part, the angle between binormal axes is 35°, and para centrally, it smoothly increases to 83.7°. The values of the main refractive indices (nx, ny, nz) change, as well as their order, from nx < nz < ny to nz < nx < ny. The transition between these two states was described with a normal distribution (µ = 0.45, σ = 0.1). The presented model corresponds with the experimental results presented in the literature. To our knowledge, it is the first model that presents the anisotropic properties' distributions of the entire cornea. The presented model facilitates a better understanding of the corneal birefringence phenomenon directly related to its lamellar structure.


Asunto(s)
Córnea , Refractometría , Humanos , Birrefringencia , Refractometría/métodos , Anisotropía , Distribución Normal
14.
Arq Bras Oftalmol ; 87(3): e20230049, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537048

RESUMEN

PURPOSE: To investigate the association of pre-photorefractive keratectomy Schirmer-1 test value with post-photorefractive keratectomy central corneal epithelial thickness, ocular surface disease index score, and uncorrected distance visual acuity. METHODS: Patients were categorized according to preoperative Schirmer-1 value: the normal Schirmer Group (n=54; Schirmer-1 test value, >10 mm) and the low Schirmer Group (n=52; Schirmer-1 test value, between 6 and 10 mm). We analyzed ablation depth, visual acuity, result of Schirmer-1 test (with anesthesia), tear film break-up time, ocular surface disease index score, central corneal epithelial thickness, and spherical equivalent refraction. RESULTS: We found significant differences between the groups in Schirmer-1 test value, tear film break-up time, and ocular surface disease index score, both preoperatively and postoperatively (p<0.001). The preoperative central corneal epithelial thicknesses of the two groups were similar (p>0.05). After photorefractive keratectomy, the Schirmer-1 test value and spherical equivalent refraction decreased in both groups (p<0.05), and ocular surface disease index scores and central corneal epithelial thickness values increased in the low Schirmer Group (p<0.001) but not in the normal Schirmer Group (p>0.05). The postoperative central corneal epithelial thicknesses of the low Schirmer Group were significantly higher than those of the normal Schirmer Group (p<0.001). Postoperative uncorrected distance visual acuity did not differ significantly between the two groups (p>0.05). CONCLUSIONS: In patients with low Schirmer-1 test values before photorefractive keratectomy, the corneal epithelium thickened and ocular surface complaints increased during the postoperative period. However, changes in the corneal epithelium did not affect the postoperative uncorrected distance visual acuity. To reduce postoperative problems on the ocular surface in these patients, we recommend that dry eye be treated before photorefractive keratectomy.


Asunto(s)
Epitelio Corneal , Miopía , Queratectomía Fotorrefractiva , Humanos , Miopía/cirugía , Agudeza Visual , Refracción Ocular , Láseres de Excímeros/uso terapéutico
15.
Vestn Oftalmol ; 140(1): 5-10, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38450460

RESUMEN

Marfan syndrome (MS) is an orphan hereditary connective tissue disease associated with a mutation in the FBN1 gene, which pathological manifestations are characterized by polysystemic involvement. The fibrillin-1 protein is an integral component of the sclera and cornea of the eye, and in MS its structure is distrubed. PURPOSE: This study assesses potential structural and functional changes in the cornea and sclera of a patient with MS. MATERIAL AND METHODS: Two groups were formed, comparable in the axial length of the eye and age: the main group - 19 patients (38 eyes) with a verified diagnosis of MS, and the control group - 24 patients (48 eyes) with myopia of varying degrees. The results obtained from MS patients were analyzed depending on the absence or presence of ectopia lentis. In addition to measuring the basic ophthalmological parameters (refraction, axial length, visual acuity), topographic keratometry, anterior segment optical coherence tomography, and ocular response analyzer were used for structural and functional assessment of the cornea and sclera. RESULTS: In MS there was a statistically significant increase in the radius of curvature and a decrease in corneal refraction in the central zone compared to the control group. There were no significant differences in central corneal thickness, but there was a significant decrease in the thickness of the sclera in the limbal zone compared to the control group. There were no statistically significant changes in corneal hysteresis and corneal resistance factor in MS. CONCLUSION: This study confirmed the previously obtained data on the tendency of the optical power to reliably decrease in MS (flattening of the cornea). This symptom can be considered as a compensatory factor affecting clinical refraction, while the decrease in the thickness of the sclera - as the main reason for aaxial length elongation in MS. There were no clear patterns of dependence of the changes in the cornea and sclera analyzed in this study on the presence or absence of ectopia lentis. Changes in the lens, perhaps, should be regarded only as one of the potential components of the ocular symptom complex in MS.


Asunto(s)
Desplazamiento del Cristalino , Síndrome de Marfan , Humanos , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Desplazamiento del Cristalino/diagnóstico , Desplazamiento del Cristalino/etiología , Córnea/diagnóstico por imagen , Esclerótica/diagnóstico por imagen , Refracción Ocular
16.
Zhonghua Yan Ke Za Zhi ; 60(3): 275-277, 2024 Mar 11.
Artículo en Chino | MEDLINE | ID: mdl-38462377

RESUMEN

A 31-year-old female patient with refractive error in both eyes underwent small incision lenticule extraction. On the 4th day after surgery, arc-shaped peripheral corneal infiltrates appeared in the right eye. Tobramycin and dexamethasone eye drops, 0.3% gatifloxacin eye drops, and a corneal bandage lens were applied to the eye. After bacterial infection was ruled out, dexamethasone sodium phosphate was injected subconjunctivally near the corneal lesion. The symptoms improved and the corneal lesion subsided afterwards.


Asunto(s)
Enfermedades de la Córnea , Cirugía Laser de Córnea , Miopía , Femenino , Humanos , Adulto , Sustancia Propia/cirugía , Agudeza Visual , Miopía/cirugía , Córnea/cirugía , Cirugía Laser de Córnea/efectos adversos , Enfermedades de la Córnea/cirugía , Soluciones Oftálmicas , Topografía de la Córnea , Refracción Ocular , Láseres de Excímeros
17.
Int Ophthalmol ; 44(1): 79, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38351423

RESUMEN

PURPOSE: To compare the outcomes, safety, efficacy, and predictability of microkeratome laser in situ keratomileusis (LASIK) 24 h and one month or more after removing soft contact lenses. SETTING: ULTRALASIK Eye Center, Dubai, United Arab Emirates. METHODS: The patients were divided based on the time of discontinuation of the soft contact lenses before LASIK (Group 1 at 24 h and Group 2 at one month or longer), and the two groups were well matched. Schirmer's testing, tear break-up time, corrected distance visual acuity, uncorrected distance visual acuity, manifest refraction spherical equivalent, and infection rate were evaluated preoperatively and at one week, one month, and six months after treatment. RESULTS: Group 1 (G1) comprised 1025 eyes, and group 2 (G2) had 1052 eyes. The groups were comparable preoperatively. The overall-mentioned outcomes were comparable between groups with uncorrected distance visual acuity of - 0.084 ± 0.12 logMAR in G1 and - 0.078 ± 0.17 logMAR in the G2 at 6 months (P = 0.322). Tear break-up time as well as Schirmer's testing results was also comparable with no evidence of increased risk of dry eyes or non-inflammatory complications in any of the groups on follow-up visits at 1 week (P = 0.421), 1 month (P = 0.101), and 6 months (P = 0.399) postoperatively. Finally, no infectious complications were recorded in either of the groups. CONCLUSION: With the absence of corneal warpage, no statistical or clinical difference in microkeratome LASIK outcomes and safety was spotted between the groups despite the difference in SCL discontinuation time before the procedure.


Asunto(s)
Queratomileusis por Láser In Situ , Miopía , Humanos , Queratomileusis por Láser In Situ/métodos , Miopía/cirugía , Miopía/etiología , Agudeza Visual , Refracción Ocular , Córnea/cirugía , Resultado del Tratamiento , Láseres de Excímeros/uso terapéutico
18.
Int Ophthalmol ; 44(1): 60, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38345707

RESUMEN

PURPOSE: To analyze higher-order aberrations (HOAs) and their visual impact in a pediatric blepharokeratoconjunctivitis (PBKC) cohort compared with healthy controls. METHODS: Prospective case-control study of pediatric patients (≤ 16 years old). Subjects underwent wavefront aberrometry analysis to compare HOAs and their impact on visual quality. RESULTS: A total of 150 eyes from 76 patients were included in the analysis. The PBKC group consisted of 50 eyes and the control group of 100 healthy eyes. Mean age was 10.39 ± 3.81 years for the PBKC group and 10.80 ± 3.61 years for the controls. Mean corrected-distance visual acuity (CDVA) was 0.24 ± 0.21 logMAR in the PBKC group and 0.07 ± 0.1 in the controls (P < 0.001). Mean astigmatism was 1.6 ± 1.98D in the PBKC group vs. 0.67 ± 0.76D in the control group (P = 0.01). Mean RMS of HOAs was 1.05 ± 1.7mm in the PBKC group and 0.41 ± 0.18mm in the controls (P < 0.001). The mean modulation transfer function (MTF) in the PBKC group was significantly lower (16.37 ± 16.32) than controls (30.3 ± 23.57) (P < 0.001). Corneal leukomas, stromal vascularization, peripheral nummular subepithelial scars, and pannus formation are associated with increased HOAs. CONCLUSIONS: There was a significant increase in total HOAs of eyes with PBKC compared to healthy controls. Corneal opacity, vascularization, and scarring are associated with increased HOAs. The PBKC eye aberration profile: coma, secondary astigmatism, quadrafoil, and pentafoil, were associated with decreased CDVA and visual quality (PSF and MTF).


Asunto(s)
Astigmatismo , Opacidad de la Córnea , Aberración de Frente de Onda Corneal , Humanos , Niño , Adolescente , Estudios de Casos y Controles , Agudeza Visual , Córnea , Refracción Ocular
19.
J Refract Surg ; 40(2): e89-e97, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38346119

RESUMEN

PURPOSE: To evaluate the effect of different whole-corneal and whole-eye higher order aberrations (HOAs) on levels of axis discrepancy. METHODS: This was a retrospective study including healthy candidates for refractive surgery, with one eye being randomly selected. A total of 360 eyes were included. Whole-corneal and whole-eye HOAs were measured twice with a Pentacam AXL Wave (Oculus Optikgeräte GmbH), and subjective manifest refraction was obtained. Axis discrepancy was defined as the absolute difference between Total Corneal Refractive Power flat keratometry axis and manifest refractive axis. Two multiple linear regression models that sought to explore the effect of HOAs in predicting axis discrepancy while adjusting for corneal and refractive confounders were built. RESULTS: Mean age was 29.1 ± 5.8 years and 63.9% of the patients were women. Mean manifest sphere and cylinder were -3.09 ± 2.36 and -1.45 ± 1.37 diopters (D), respectively. Mean cylinder axis discrepancy was 14.4 ± 14.5°. On multiple linear regression, the only variables significantly associated with axis discrepancy were corneal cylinder and corneal lower order aberrations [F(5,339) = 29.746; P < .001; adjusted R2 = 0.295]. Lower levels of corneal cylinder are by far the main contributor to astigmatism axis mismatch (ß = -1.164). There was not a single HOA, either corneal or ocular, that significantly loaded into any models. CONCLUSIONS: Astigmatism axis mismatch decreases rapidly with increasing levels of corneal astigmatism. Corneal and whole-eye HOAs have no role in astigmatism axis mismatch in healthy candidates for refractive surgery. [J Refract Surg. 2024;40(2):e89-e97.].


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Procedimientos Quirúrgicos Refractivos , Humanos , Femenino , Adulto Joven , Adulto , Masculino , Astigmatismo/diagnóstico , Astigmatismo/cirugía , Estudios Retrospectivos , Agudeza Visual , Topografía de la Córnea , Refracción Ocular , Córnea/cirugía , Enfermedades de la Córnea/cirugía
20.
Asia Pac J Ophthalmol (Phila) ; 13(1): 100029, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38383079

RESUMEN

PURPOSE: To evaluate the efficacy of perioperative IPL therapy in preventing postoperative ocular surface disorders in patients undergoing corneal laser refractive surgery. DESIGN: randomized, controlled, clinical trial with triple-blinding. METHODS: Setting: Vissum Miranza - Alicante; Study population: 61 patients randomized in two groups: 31 study patients (perioperative IPL + laser refractive surgery) and 30 control patients (perioperative placebo + laser refractive surgery). Follow-up was conducted over a 6-month period; Intervention: Each participants underwent three IPL sessions with a two-week interval between each session (pre-surgery, post-surgery week-one, and post-surgery week-three). For controls, placebo was administered following the same protocol. MAIN OUTCOMES MEASURES: visual outcomes and refraction, slit-lamp examination, corneal topography, visual analogue scale questionnaire and Oculus Keratograph 5 M including tear meniscus height, non-invasive tear break- up time, ocular redness, infrared meibography and Ocular Surface Disease Index (OSDI) questionnaire. RESULTS: 61 randomized eyes were included. No significant differences were observed in terms of uncorrected and corrected distance visual acuity (UDVA, CDVA), refractive error or corneal aberrations. A statistically significant improvement in OSDI score (change -8.47, p = 0.043), tear meniscus (change 0.05 mm, p = 0.004) and Meibography (change -0.42, p = 0.012) was observed at the third postoperative month in the study group. Additionally, at the sixth postoperative month, there were statistically significant improvements in tear meniscus (change 0.06 mm, p = 0.018), tear break-up-time (change 1.68 s, p = 0.039) and Meibography (change -0.37, p = 0.030). CONCLUSIONS: Results suggest that perioperative IPL therapy applied to laser corneal refractive surgery improves objective and subjective ocular surface parameters over non-IPL-treated control patients and early postoperative dry eye symptoms.


Asunto(s)
Síndromes de Ojo Seco , Miopía , Procedimientos Quirúrgicos Refractivos , Humanos , Miopía/cirugía , Refracción Ocular , Córnea , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/prevención & control , Lágrimas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...