Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.194
Filtrar
1.
Technol Cancer Res Treat ; 23: 15330338241264848, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39129335

RESUMO

OBJECTIVE: To investigate the effect of various frequencies of bolus use on the superficial dose of volumetric modulated arc therapy after modified radical mastectomy for breast cancer. METHODS: Based on the computed tomography images of a female anthropomorphic breast phantom, a 0.5 cm silicone-based 3D-printed bolus was created. Nine points evenly distributed on the breast skin were selected for assessing the skin dose, and a volume of subcutaneous lymphatic drainage of the breast (noted as ROI2-3) was delineated for assessing the chest wall dose. The treatment plans with and without bolus (plan_wb and plan_nb) were separately designed using the prescription of 50 Gy in 25 fractions following the standard dose constraints of the adjacent organ at risk. To characterize the accuracy of treatment planning system (TPS) dose calculations, the doses of the nine points were measured five times by thermoluminescence dosimeters (TLDs) and then were compared with the TPS calculated dose. RESULTS: Compared with Plan_nb (144.46 ± 10.32 cGy), the breast skin dose for plan_wb (208.75 ± 4.55 cGy) was significantly increased (t = -18.56, P < 0.001). The deviation of skin dose was smaller for Plan_wb, and the uniformity was significantly improved. The calculated value of TPS was in good agreement with the measured value of TLD, and the maximum deviation was within 5%. Skin and ROI2-3 doses were significantly increased with increasing frequencies of bolus applications. The mean dose of the breast skin and ROI2-3 for 15 and 23 times bolus applications were 45.33 Gy, 50.88 Gy and 50.36 Gy, 52.39 Gy, respectively. CONCLUSION: 3D printing bolus can improve the radiation dose and the accuracy of the planned dose. Setting Plan_wb to 15 times for T1-3N+ breast cancer patients and 23 times for T4N+ breast cancer patients can meet the clinical need. Quantitative analysis of the bolus application frequency for different tumor stages can provide a reference for clinical practice.


Assuntos
Neoplasias da Mama , Mastectomia Radical Modificada , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Mastectomia Radical Modificada/métodos , Radiometria/métodos , Órgãos em Risco , Tomografia Computadorizada por Raios X
3.
Radiat Oncol ; 19(1): 104, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095864

RESUMO

BACKGROUND: Radiotherapy (RT) in head and neck squamous cell cancer (HNSCC) often leads to sticky saliva and xerostomia (SSX). Dose sparing of salivary glands (SG) reduces occurrence of SSX but few studies investigated the relationship between RT dose to SG substructures and SSX. We therefore investigated this hypothesis, focusing on the parotid duct (PD). METHODS: Retrospective data was collected from 99 HNSCC patients treated at our center with (chemo-)radiotherapy (CRT). PD and other organs-at-risk (OAR) were (re-)contoured and DVHs were generated without re-planning. SSX was graded according to CTCAE v.4.03 and evaluated at acute, subacute, and two late timepoints. RESULTS: Most patients presented with loco-regionally advanced disease. In 47% of patients, up-front neck dissection preceded CRT. Weighted mean dose was 28.6 Gy for bilateral parotid glands (PG), and 32.0 Gy for PD. Acute SSX presented as grades 0 (35.3%), I (41.4%), II (21.2%) and III (2.0%). There was no association of OARs and SSX ≥ grade 2 in univariable logistic regression (LR). Multivariable LR showed statistically significant relationship of acute SSX with: PG weighted mean dose (OR 0.84, p = 0.004), contralateral PG mean dose (OR 1.14, p = 0.02) and contralateral PD planning OAR (PD PRV) mean dose (OR 1.84, p = 0.03). CONCLUSIONS: There was an association of acute SSX with dose exposure of PD PRV in multivariable regression, only. Due to statistical uncertainties and the retrospective nature of this analysis, further studies are required to confirm or reject the hypothesis.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Glândula Parótida , Dosagem Radioterapêutica , Carcinoma de Células Escamosas de Cabeça e Pescoço , Xerostomia , Humanos , Xerostomia/etiologia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Glândula Parótida/efeitos da radiação , Idoso , Neoplasias de Cabeça e Pescoço/radioterapia , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Adulto , Idoso de 80 Anos ou mais , Saliva/efeitos da radiação , Lesões por Radiação/etiologia , Carcinoma de Células Escamosas/radioterapia , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
5.
BMC Cancer ; 24(1): 1041, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39174903

RESUMO

BACKGROUND AND PURPOSE: Ir192 vaginal brachytherapy (IBT) is commonly used for patients with postoperative endometrial cancer (EC). We devised a novel multichannel vaginal applicator that could be equipped with an electronic brachytherapy (EBT) device. We aimed to explore the differences in physical parameters between the EBT and IBT. MATERIALS AND METHODS: This retrospective study included 20 EC patients who received adjuvant IBT from March 1, 2023, to May 1, 2023. Multichannel vaginal cylinders were used, and three-dimensional plans were generated. We designed an electronic multichannel vaginal applicator model and simulated a three-dimensional EBT plan. In order to ensure comparability, D90 of the CTV for the EBT plan was normalized to be equivalent to that of the IBT plan for the same patient. RESULTS: Twenty EBT plans were compared with 20 IBT plans. Results showed, the mean D90 value of clinical target volume (CTV) was 536.1 cGy for both treatment plans. For the mean dose of CTV, the EBT was significantly greater (738.3 vs. 684.3 cGy, p = 0.000). There was no significant difference in CTV coverage between the EBT and IBT plans. For high-dose areas (V200% and V150%), the EBTs were significantly greater. There were no significant differences in the maximum doses to the vaginal mucosa between the EBT and IBT, whether at the apex or in the middle segment. For the bladder and rectum, both the low-dose area and high-dose area were significantly lower in the EBT plans. For the conformity index, there was no significant difference between the EBT and IBT plans. For the dose homogeneity index, the EBT value was lower. CONCLUSION: In conclusion, under the premise of a three-dimensional brachytherapy plan, for patients receiving multichannel vaginal applicator brachytherapy, compared with IBT, EBT could reduce the dose to the surrounding organs at risk while maintaining the dose in the target area.


Assuntos
Braquiterapia , Neoplasias do Endométrio , Radioisótopos de Irídio , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Feminino , Braquiterapia/métodos , Braquiterapia/instrumentação , Neoplasias do Endométrio/radioterapia , Neoplasias do Endométrio/patologia , Estudos Retrospectivos , Radioisótopos de Irídio/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Pessoa de Meia-Idade , Idoso , Radiometria , Órgãos em Risco/efeitos da radiação
6.
Technol Cancer Res Treat ; 23: 15330338241272038, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39106410

RESUMO

PURPOSE: This study aims to investigate the influence of the magnetic field on treatment plan quality using typical phantom test cases, which encompass a circle target test case, AAPM TG119 test cases (prostate, head-and-neck, C-shape, multi-target test cases), and a lung test case. MATERIALS AND METHODS: For the typical phantom test cases, two plans were formulated. The first plan underwent optimization in the presence of a 1.5 Tesla magnetic field (1.5 T plan). The second plan was re-optimized without a magnetic field (0 T plan), utilizing the same optimization conditions as the first plan. The two plans were compared based on various parameters, including con-formity index (CI), homogeneity index (HI), fit index (FI) and dose coverage of the planning target volume (PTV), dose delivered to organs at risk (OARs) and normal tissue (NT), monitor unit (MU). A plan-quality metric (PQM) scoring procedure was employed. For the 1.5 T plans, dose verifications were performed using an MR-compatible ArcCHECK phantom. RESULTS: A smaller dose influence of the magnetic field was found for the circle target, prostate, head-and-neck, and C-shape test cases, compared with the multi-target and lung test cases. In the multi-target test case, the significant dose influence was on the inferior PTV, followed by the superior PTV. There was a relatively large dose influence on the PTV and OARs for lung test case. No statistically significant differences in PQM and MUs were observed. For the 1.5 T plans, gamma passing rates were all higher than 95% with criteria of 2 mm/3% and 2 mm/2%. CONCLUSION: The presence of a 1.5 T magnetic field had a relatively large impact on dose parameters in the multi-target and lung test cases compared with other test cases. However, there were no significant influences on the plan-quality metric, MU and dose accuracy for all test cases.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Órgãos em Risco , Neoplasias/radioterapia , Masculino , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Próstata/radioterapia
7.
Radiat Oncol ; 19(1): 101, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090684

RESUMO

BACKGROUND: Prostate cancer in younger men is rare but not exceptional. Radiotherapy is a cornerstone of prostate cancer treatment and yet, its impact on fertility is scarcely reported in literature. Given the radiosensitivity of testicular tissue, this study aimed to determine the testicular dose using modern radiotherapy techniques for definitive prostate irradiation. METHODS: One hundred radiotherapy plans were reviewed. Testicles were contoured retrospectively without dosimetric optimization on testicles. RESULTS: The median testicular dose was 0.58 Gy: 0.18 Gy in stereotactic plans, 0.62 Gy in Volumetric Modulated Arc Therapy plans and 1.50 Gy in Tomotherapy plans (p < 0.001). Pelvic nodal irradiation increased the median testicular dose to 1.18 Gy versus 0.26 Gy without nodal irradiation (p < 0.001). Weight and BMI were inversely associated with testicular dose (p < 0.005). 65% of patients reached the theoretical dose threshold for transient azoospermia, and 10% received more than 2 Gy, likely causing definitive azoospermia. CONCLUSION: Despite being probably lower than doses from older techniques, the testicular dose delivered with modern prostate radiotherapy is not negligible and is often underestimated because the contribution of daily repositioning imaging is not taken into account and most Treatment Planning Systems underestimate the out of field dose. Radiation oncologists should consider the impact on fertility and gonadal endocrine function, counseling men on sperm preservation if they wish to maintain fertility. TRIAL REGISTRATION: retrospectively registered.


Assuntos
Neoplasias da Próstata , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Testículo , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Estudos Retrospectivos , Testículo/efeitos da radiação , Pessoa de Meia-Idade , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Idoso , Adulto , Lesões por Radiação/etiologia , Fertilidade/efeitos da radiação
8.
Klin Onkol ; 38(1): 10-19, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39183546

RESUMO

BACKGROUND: Cardiovascular diseases represent the most common non-oncologic cause of death in patients following radiotherapy (RT) in the thoracic region. Radiation-induced heart disease (RIHD) can manifest as various heterogeneous clinical entities. However, the influence of RT on the cardiac conduction system has only recently gained more attention. Arrhythmogenic toxicity, i.e., conduction disorders and arrhythmias, constitutes a significant part of these adverse effects. The cardiac conduction system is not routinely monitored as an organ at risk (OaR). Its specific histological nature and function suggest different sensitivity and response to radiation. The heart is a highly heterogeneous organ, and the routinely monitored dose to the whole heart may not adequately characterize the risk of increased arrhythmogenic toxicity from RT. Cardiac structures, including the conduction system, appear to be additional OaRs for which dose distribution should be monitored. MATERIAL AND METHODS: For the systematic selection of studies, we utilized the PubMed database with keywords derived from the analysis of existing literature. The search was limited to English-language publications, and the selection criteria included relevance to the topic and the quality of methodology. PURPOSE: This article summarizes the impact of RT on the cardiac conduction system. CONCLUSION: Radiotherapy-induced cardiotoxicity significantly affects morbidity and mortality. The heart exhibits heterogeneity in terms of radiosensitivity. Certain cardiac subregions in the dose distribution show a higher correlation with poorer overall survival than routinely monitored doses to the whole heart and derived parameters (the volumes irradiated with the doses of 5 or 30 Gy - V5 or V30, respectively). The most radiosensitive subregions appear to be the base of the heart, including the beginning of the conduction system. Higher doses to the conduction system, especially the sinoatrial (SA) node, are associated with a higher incidence of a wide range of arrhythmias and poorer overall survival. However, dose limits (Dmean and Dmax) for the conduction system have not yet been established. Dosimetric studies have identified cutoff doses to the SA node, exceeding which there is a significant increase in mortality and the occurrence of arrhythmias.


Assuntos
Sistema de Condução Cardíaco , Humanos , Sistema de Condução Cardíaco/efeitos da radiação , Sistema de Condução Cardíaco/fisiopatologia , Radioterapia/efeitos adversos , Órgãos em Risco/efeitos da radiação , Arritmias Cardíacas/etiologia , Lesões por Radiação/etiologia
9.
Phys Med ; 124: 104492, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39094213

RESUMO

PURPOSE: The purpose of the study is to investigate the clinical application of deep learning (DL)-assisted automatic radiotherapy planning for lung cancer. METHODS: A DL model was developed for predicting patient-specific doses, trained and validated on a dataset of 235 patients with diverse target volumes and prescriptions. The model was integrated into clinical workflow with DL-predicted objective functions. The automatic plans were retrospectively designed for additional 50 treated manual volumetric modulated arc therapy (VMAT) plans. A comparison was made between automatic and manual plans in terms of dosimetric indexes, monitor units (MUs) and planning time. Plan quality metric (PQM) encompassing these indexes was evaluated, with higher PQM values indicating superior plan quality. Qualitative evaluations of two plans were conducted by four reviewers. RESULTS: The PQM score was 40.7 ± 13.1 for manual plans and 40.8 ± 13.5 for automatic plans (P = 0.75). Compared to manual plans, the targets coverage and homogeneity of automatic plans demonstrated no significant difference. Manual plans exhibited better sparing for lung in V5 (difference: 1.8 ± 4.2 %, P = 0.02), whereas automatic plans showed enhanced sparing for heart in V30 (difference: 1.4 ± 4.7 %, P = 0.02) and for spinal cord in Dmax (difference: 0.7 ± 4.7 Gy, P = 0.04). The planning time and MUs of automatic plans were significantly reduced by 70.5 ± 20.0 min and 97.4 ± 82.1. Automatic plans were deemed acceptable in 88 % of the reviews (176/200). CONCLUSIONS: The DL-assisted approach for lung cancer notably decreased planning time and MUs, while demonstrating comparable or superior quality relative to manual plans. It has the potential to provide benefit to lung cancer patients.


Assuntos
Automação , Aprendizado Profundo , Neoplasias Pulmonares , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Neoplasias Pulmonares/radioterapia , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Órgãos em Risco/efeitos da radiação
10.
BMC Cancer ; 24(1): 936, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090564

RESUMO

PURPOSE: To evaluate the dosimetric characteristics of ZAP-X stereotactic radiosurgery (SRS) for single brain metastasis by comparing with two mature SRS platforms. METHODS: Thirteen patients with single brain metastasis treated with CyberKnife (CK) G4 were selected retrospectively. The prescription dose for the planning target volume (PTV) was 18-24 Gy for 1-3 fractions. The PTV volume ranged from 0.44 to 11.52 cc.Treatment plans of thirteen patients were replanned using the ZAP-X plan system and the Gamma Knife (GK) ICON plan system with the same prescription dose and organs at risk (OARs) constraints. The prescription dose of PTV was normalized to 70% for both ZAP-X and CK, while it was 50% for GK. The dosimetric parameters of three groups included the plan characteristics (CI, GI, GSI, beams, MUs, treatment time), PTV (D2, D95, D98, Dmin, Dmean, Coverage), brain tissue (volume of 100%-10% prescription dose irradiation V100%-V10%, Dmean) and other OARs (Dmax, Dmean),all of these were compared and evaluated. All data were read and analyzed with MIM Maestro. One-way ANOVA or a multisample Friedman rank sum test was performed, where p < 0.05 indicated significant differences. RESULTS: The CI of GK was significantly lower than that of ZAP-X and CK. Regarding the mean value, ZAP-X had a lower GI and higher GSI, but there was no significant difference among the three groups. The MUs of ZAP-X were significantly lower than those of CK, and the mean value of the treatment time of ZAP-X was significantly shorter than that of CK. For PTV, the D95, D98, and target coverage of CK were higher, while the mean of Dmin of GK was significantly lower than that of CK and ZAP-X. For brain tissue, ZAP-X showed a smaller volume from V100% to V20%; the statistical results of V60% and V50% showed a difference between ZAP-X and GK, while the V40% and V30% showed a significant difference between ZAP-X and the other two groups; V10% and Dmean indicated that GK was better. Excluding the Dmax of the brainstem, right optic nerve and optic chiasm, the mean value of all other OARs was less than 1 Gy. For the brainstem, GK and ZAP-X had better protection, especially at the maximum dose. CONCLUSION: For the SRS treating single brain metastasis, all three treatment devices, ZAP-X system, CyberKnife G4 system, and GammaKnife system, could meet clinical treatment requirements. The newly platform ZAP-X could provide a high-quality plan equivalent to or even better than CyberKnife and Gamma Knife, with ZAP-X presenting a certain dose advantage, especially with a more conformal dose distribution and better protection for brain tissue. As the ZAP-X systems get continuous improvements and upgrades, they may become a new SRS platform for the treatment of brain metastasis.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Radiocirurgia/métodos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Masculino , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Radiometria , Idoso , Adulto , Órgãos em Risco/efeitos da radiação
11.
J Cancer Res Ther ; 20(3): 763-769, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023580

RESUMO

PURPOSE: The current study aims to compare the split x-jaw planning technique of volumetric modulated arc radiotherapy (VMAT) with the traditional open and limited jaw techniques of VAMT in nasopharyngeal carcinoma treatment. The multi-leaf collimators on the varian linear accelerator move on a carriage with a maximum leaf span of 15 cm. Therefore, treatment of larger planning target volumes, such as in nasopharyngeal cancer with traditional open and limited jaw technique, yields compromised dose distribution. METHOD: Computed tomography data sets of 10 nasopharynx cancer patients were enrolled for the study. For each case, three separate treatment plans were generated viz. open, limited, and split x-jaw planning techniques with similar planning objectives. Only PTVs requiring a field size larger than 18 cm in the x-jaw position were considered. RESULTS: Comparable results were obtained regarding organs at risk (OAR) sparing in all the techniques. The target dose coverage with split x-jaw VMAT was superior to both open and limited jaw planning techniques, with a statistically significant difference in the intermediate dose planning target volumes (PTVs) (PTV59.4), P < 0.05. However, the split technique's dose to the spinal cord and larynx was significantly lower (P < 0.05). CONCLUSION: The split x-jaw planning technique of VMAT can be adapted for larger PTVs requiring an x-jaw of more than 15 cm. The only concern with this technique is the increased MU.


Assuntos
Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Nasofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Carcinoma Nasofaríngeo/radioterapia , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Masculino
12.
J Cancer Res Ther ; 20(3): 943-948, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023602

RESUMO

PURPOSE: Low-dose radiation therapy (LDRT) to lungs did show encouraging results in COVID-19 patients in some clinical trials. However, there has been some concern regarding the long-term risk of radiation-induced cancer (RIC). Compared to the conventional AP-PA field technique, volumetric modulated arc therapy (VMAT) can potentially reduce the dose to the marrow and other organs at risk (OARs) and thus minimize the risk of cancer. We designed a dosimetry study to study if VMAT can reduce the exposure to the marrow and other OAR doses and curtail the estimated life-time attributable risk (LAR) of cancer. METHODS AND MATERIALS: We retrieved the computed tomography scan data of 10 patients (aged 40-60 years, median 48 years) who have been already treated for any malignancy in the region of the thorax. A dose of 1.0 Gy in single fraction was prescribed to both lungs. All the organs were delineated as per the established guidelines. The dosimetry achieved by the two plans was compared to find the difference. Mean OAR doses were used to estimate the LAR for both plans and compared. RESULTS: Planning target volume coverage parameters like conformity index and homogeneity index were significantly better with VMAT (P value < 0.05 for all). The mean dose to most OARs was significantly lower with VMAT (P value < 0.05 for all). The mean dose to the marrow was significantly lower with VMAT (59.05 vs 81.9 cGy with P value < 0.05). The overall LAR was significantly lower with VMAT as compared to the conventional plan (0.357% vs 0.398%, P value < 0.05). CONCLUSION: Compared to the conventional technique, VMAT provides better OAR dosimetry for lung irradiation (a prescription dose of 1.0 Gy or more) in COVID-19 pneumonia. VMAT significantly reduces the risk of RIC. We therefore suggest if lung LDRT is used for COVID-19 patients, VMAT is the preferred technique for a prescription dose of ≥1.0 Gy.


Assuntos
Medula Óssea , COVID-19 , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , SARS-CoV-2 , Humanos , COVID-19/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Pessoa de Meia-Idade , Masculino , Órgãos em Risco/efeitos da radiação , Adulto , Planejamento da Radioterapia Assistida por Computador/métodos , Medula Óssea/efeitos da radiação , Feminino , Pulmão/efeitos da radiação , Pulmão/diagnóstico por imagem , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/prevenção & controle
13.
J Cancer Res Ther ; 20(3): 1020-1025, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023610

RESUMO

PURPOSE/OBJECTIVE S: Due to manual OAR contouring challenges, various automatic contouring solutions have been introduced. Historically, common clinical auto-segmentation algorithms used were atlas-based, which required maintaining a library of self-made contours. Searching the collection was computationally intensive and could take several minutes to complete. Deep learning approaches have shown significant benefits compared to atlas-based methods in improving segmentation accuracy and efficiency in auto-segmentation algorithms. This work represents the first multi-institutional study to describe and evaluate an AI algorithm for the auto-segmentation of organs at risk (OARs) based on a deep image-to-image network (DI2IN). MATERIALS/METHODS: The AI-Rad Companion Organs RT (AIRC) algorithm (Siemens Healthineers, Erlangen, Germany) uses a two-step approach for segmentation. In the first step, the target organ region in the optimal input image is extracted using a trained deep reinforcement learning network (DRL), which is then used as input to create the contours in the second step based on DI2IN. The study was initially designed as a prospective single-center evaluation. The automated contours generated by AIRC were evaluated by three experienced board-certified radiation oncologists using a four-point scale where 4 is clinically usable and 1 requires re-contouring. After seeing favorable results in a single-center pilot study, we decided to expand the study to six additional institutions, encompassing eight additional evaluators for a total of 11 physician evaluators across seven institutions. RESULTS: One hundred and fifty-six patients and 1366 contours were prospectively evaluated. The five most commonly contoured organs were the lung (136 contours, average rating = 4.0), spinal cord (106 contours, average rating = 3.1), eye globe (80 contours, average rating = 3.9), lens (77 contours, average rating = 3.9), and optic nerve (75 contours, average rating = 4.0). The average rating per evaluator per contour was 3.6. On average, 124 contours were evaluated by each evaluator. 65% of the contours were rated as 4, and 31% were rated as 3. Only 4% of contours were rated as 1 or 2. Thirty-three organs were evaluated in the study, with 19 structures having a 3.5 or above average rating (ribs, abdominopelvic cavity, skeleton, larynx, lung, aorta, brachial plexus, lens, eye globe, glottis, heart, parotid glands, bladder, kidneys, supraglottic larynx, submandibular glands, esophagus, optic nerve, oral cavity) and the remaining organs having a rating of 3.0 or greater (female breast, proximal femur, seminal vesicles, rectum, sternum, brainstem, prostate, brain, lips, mandible, liver, optic chiasm, spinal cord, spleen). No organ had an average rating below 3. CONCLUSION: AIRC performed well with greater than 95% of contours accepted by treating physicians with no or minor edits. It supported a fully automated workflow with the potential for time savings and increased standardization with the use of AI-powered algorithms for high-quality OAR contouring.


Assuntos
Algoritmos , Aprendizado Profundo , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Institutos de Câncer/normas
14.
Int J Mol Sci ; 25(13)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39000587

RESUMO

Recombinant α1-microglobulin (A1M) is proposed as a protector during 177Lu-octreotate treatment of neuroendocrine tumors, which is currently limited by bone marrow and renal toxicity. Co-administration of 177Lu-octreotate and A1M could result in a more effective treatment by protecting healthy tissue, but the radioprotective action of A1M is not fully understood. The aim of this study was to examine the proteomic response of kidneys and bone marrow early after 177Lu-octreotate and/or A1M administration. Mice were injected with 177Lu-octreotate and/or A1M, while control mice received saline or A1M vehicle solution. Bone marrow, kidney medulla, and kidney cortex were sampled after 24 h or 7 d. The differential protein expression was analyzed with tandem mass spectrometry. The dosimetric estimation was based on 177Lu activity in the kidney. PHLDA3 was the most prominent radiation-responsive protein in kidney tissue. In general, no statistically significant difference in the expression of radiation-related proteins was observed between the irradiated groups. Most canonical pathways were identified in bone marrow from the 177Lu-octreotate+A1M group. Altogether, a tissue-dependent proteomic response followed exposure to 177Lu-octreotate alone or together with A1M. Combining 177Lu-octreotate with A1M did not inhibit the radiation-induced protein expression early after exposure, and late effects should be further studied.


Assuntos
alfa-Globulinas , Octreotida , Proteômica , Animais , alfa-Globulinas/metabolismo , Camundongos , Octreotida/farmacologia , Octreotida/análogos & derivados , Proteômica/métodos , Proteínas Recombinantes/farmacologia , Rim/metabolismo , Rim/efeitos da radiação , Rim/efeitos dos fármacos , Masculino , Medula Óssea/efeitos da radiação , Medula Óssea/metabolismo , Medula Óssea/efeitos dos fármacos , Órgãos em Risco/efeitos da radiação , Proteoma/metabolismo , Protetores contra Radiação/farmacologia
15.
PLoS One ; 19(7): e0308181, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39083552

RESUMO

PURPOSE: Organ-at-risk segmentation is essential in adaptive radiotherapy (ART). Learning-based automatic segmentation can reduce committed labor and accelerate the ART process. In this study, an auto-segmentation model was developed by employing individual patient datasets and a deep-learning-based augmentation method for tailoring radiation therapy according to the changes in the target and organ of interest in patients with prostate cancer. METHODS: Two computed tomography (CT) datasets with well-defined labels, including contoured prostate, bladder, and rectum, were obtained from 18 patients. The labels of the CT images captured during radiation therapy (CT2nd) were predicted using CT images scanned before radiation therapy (CT1st). From the deformable vector fields (DVFs) created by using the VoxelMorph method, 10 DVFs were extracted when each of the modified CT and CT2nd images were deformed and registered to the fixed CT1st image. Augmented images were acquired by utilizing 110 extracted DVFs and spatially transforming the CT1st images and labels. An nnU-net autosegmentation network was trained by using the augmented images, and the CT2nd label was predicted. A patient-specific model was created for 18 patients, and the performances of the individual models were evaluated. The results were evaluated by employing the Dice similarity coefficient (DSC), average Hausdorff distance, and mean surface distance. The accuracy of the proposed model was compared with those of models trained with large datasets. RESULTS: Patient-specific models were developed successfully. For the proposed method, the DSC values of the actual and predicted labels for the bladder, prostate, and rectum were 0.94 ± 0.03, 0.84 ± 0.07, and 0.83 ± 0.04, respectively. CONCLUSION: We demonstrated the feasibility of automatic segmentation by employing individual patient datasets and image augmentation techniques. The proposed method has potential for clinical application in automatic prostate segmentation for ART.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Masculino , Tomografia Computadorizada por Raios X/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco , Bexiga Urinária/diagnóstico por imagem , Próstata/diagnóstico por imagem , Próstata/patologia
16.
Phys Med Biol ; 69(16)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39079553

RESUMO

Objective.Dynamic trajectory radiotherapy (DTRT) and dynamic mixed-beam arc therapy (DYMBARC) exploit non-coplanarity and, for DYMBARC, simultaneously optimized photon and electron beams. Margin concepts to account for set-up uncertainties during delivery are ill-defined for electron fields. We develop robust optimization for DTRT&DYMBARC and compare dosimetric plan quality and robustness for both techniques and both optimization strategies for four cases.Approach.Cases for different treatment sites and clinical target volume (CTV) to planning target volume (PTV) margins,m, were investigated. Dynamic gantry-table-collimator photon paths were optimized to minimize PTV/organ-at-risk (OAR) overlap in beam's-eye-view and minimize potential photon multileaf collimator (MLC) travel. For DYMBARC plans, non-isocentric partial electron arcs or static fields with shortened source-to-surface distance (80 cm) were added. Direct aperture optimization (DAO) was used to simultaneously optimize MLC-based intensity modulation for both photon and electron beams yielding deliverable PTV-based DTRT&DYMBARC plans. Robust-optimized plans used the same paths/arcs/fields. DAO with stochastic programming was used for set-up uncertainties with equal weights in all translational directions and magnitudeδsuch thatm= 0.7δ. Robust analysis considered random errors in all directions with or without an additional systematic error in the worst 3D direction for the adjacent OARs.Main results.Electron contribution was 7%-41% of target dose depending on the case and optimization strategy for DYMBARC. All techniques achieved similar CTV coverage in the nominal (no error) scenario. OAR sparing was overall better in the DYMBARC plans than in the DTRT plans and DYMBARC plans were generally more robust to the considered uncertainties. OAR sparing was better in the PTV-based than in robust-optimized plans for OARs abutting or overlapping with the target volume, but more affected by uncertainties.Significance.Better plan robustness can be achieved with robust optimization than with margins. Combining electron arcs/fields with non-coplanar photon trajectories further improves robustness and OAR sparing.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Órgãos em Risco/efeitos da radiação , Fótons/uso terapêutico , Radiometria/métodos , Elétrons/uso terapêutico
17.
Radiat Prot Dosimetry ; 200(13): 1274-1293, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39003236

RESUMO

The verification and use of the best treatment approach using 3D conformal radiation therapy (3DCRT), intensity modulated radiation therapy (IMRT) and Rapid Arc methods for left breast radiation with dosimetric and radiobiological characteristics. The use of custom-built Python software for the estimation and comparison of volume, mean dose, maximum dose, monitor units and normal tissue integral dose along with radiobiological parameters such as NTCP, tumor control probability, equivalent uniform dose and LKB's effective volume from 3DCRT, IMRT and Rapid Arc planning with deep inspiration with breath holding (DIBH) and free breadth (FB) techniques. Volume growth of three-fourth in DIBH compared with FB causes a decrease in cardiac doses and complications because the left lung expands, pulling the heart away from the chest wall and the treatment area. A tiny area of the left lung was exposed during treatment, which reduced the mean dose. There was little difference in the treatment approaches because the spinal cord was immobile in both techniques. Rapid Arc is the unmatched modality for left-sided breast irradiation with significant patient breath-hold, as shown by the comparison of dosimetric and radiobiological parameters from treatment techniques with a deep inspiration breath-hold approach.


Assuntos
Suspensão da Respiração , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Unilaterais da Mama/radioterapia , Radioterapia Conformacional/métodos , Órgãos em Risco/efeitos da radiação , Radiometria/métodos
18.
Phys Med ; 124: 103423, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38970949

RESUMO

PURPOSE: This study aimed to analyse correlations between planning factors including plan geometry and plan complexity with robustness to patient setup errors. METHODS: Multiple-target brain stereotactic radiosurgery (SRS) plans were obtained through the Trans-Tasman Radiation Oncology Group (TROG) international treatment planning challenge (2018). The challenge dataset consisted of five intra-cranial targets with a 20 Gy prescription. Setup error was simulated using an in-house tool. Dose to targets was assessed via dose covering 99 % (D99 %) of gross tumour volume (GTV) and 98 % of planning target volume (PTV). Dose to organs at risk was assessed using volume of normal brain receiving 12 Gy and maximum dose covering 0.03 cc of brainstem. Plan complexity was assessed via edge metric, modulation complexity score, mean multi-leaf collimator (MLC) gap, mean MLC speed and plan modulation. RESULTS: Even for small (0.5 mm/°) errors, GTV D99 % was reduced by up to 20 %. The strongest correlation was found between lower complexity plans (larger mean MLC gap and lower edge metric) and higher robustness to setup error. Lower complexity plans had 1 %-20 % fewer targets/scenarios with GTV D99 % falling below the specified tolerance threshold. These complexity metrics correlated with 100 % isodose volume sphericity and dose conformity, though similar conformity was achievable with a range of complexities. CONCLUSIONS: A higher level of importance should be directed towards plan complexity when considering plan robustness. It is recommended when planning multi-target SRS, larger MLC gaps and lower MLC aperture irregularity be considered during plan optimisation due to higher robustness should patient positioning errors occur.


Assuntos
Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Erros de Configuração em Radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Erros de Configuração em Radioterapia/prevenção & controle , Dosagem Radioterapêutica , Órgãos em Risco/efeitos da radiação , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia
19.
Clin Oncol (R Coll Radiol) ; 36(9): 562-575, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39013657

RESUMO

Anatomical models have key applications in radiotherapy, notably to help understand the relationship between radiation dose and risk of developing side effects. This review analyses whether age-specific computational phantoms, developed from healthy subjects and paediatric cancer patient data, are adequate to model a paediatric population. The phantoms used in the study were International Commission on Radiological Protection (ICRP), 4D extended cardiac torso (XCAT) and Radiotherapy Paediatric Atlas (RT-PAL), which were also compared to literature data. Organ volume data for 19 organs was collected for all phantoms and literature. ICRP was treated as the reference for comparison, and percentage difference (P.D) for the other phantoms were calculated relative to ICRP. Overall comparisons were made for each age category (1, 5, 10, 15) and each organ. Statistical analysis was performed using Microsoft Excel (version 16.59). The smallest P.D to ICRP was for Literature (-17.4%), closely followed by XCAT (26.6%). The largest was for RT-PAL (88.1%). The rectum had the largest average P.D (1,049.2%) and the large bowel had the smallest (2.0%). The P.D was 122.6% at age 1 but this decreased to 43.5% by age 15. Linear regression analysis showed a correlation between organ volume and age to be the strongest for ICRP (R2 = 0.943) and weakest for XCAT (R2 = 0.676). The phantoms are similar enough to ICRP for potential use in modelling paediatric populations. ICRP and XCAT could be used to model a healthy population, whereas RT-PAL could be used for a population undergoing/after radiotherapy.


Assuntos
Modelos Anatômicos , Humanos , Criança , Imagens de Fantasmas , Neoplasias/radioterapia , Pré-Escolar , Órgãos em Risco/efeitos da radiação , Radioterapia/métodos , Dosagem Radioterapêutica , Lactente , Adolescente , Planejamento da Radioterapia Assistida por Computador/métodos
20.
Radiat Environ Biophys ; 63(3): 423-431, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38969869

RESUMO

This retrospective study was performed to evaluate plan quality and treatment delivery parameters of stereotactic body radiation therapy (SBRT) for prostate cancer. The study utilized different isocentric modulated techniques: intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using 6 MV flattening filter (FF) and 10 MV flattening filter-free beams (FFF). Fifteen retrospective prostate cancer patients were selected for this study. Sixty plans were created with an SBRT-prescribed dose of 36.25 Gy delivered in five fractions. Planning target volume (PTV) coverage, plan quality indices, doses delivered to organs at risk (OARs), and treatment delivery parameters were compared for all plans. It turned out that VMAT plans, particularly those using the FFF beam, provided superior target conformality and a steeper dose gradient as compared to IMRT plans. Additionally, VMAT plans showed better OARs sparing compared to IMRT plans. However, IMRT plans delivered a lower maximum dose to the target than VMAT plans. Importantly, the VMAT plans resulted in reduced treatment delivery parameters, including beam on time (BOT), monitor unit (MU), and modulation factor (MF), compared to IMRT plans. Furthermore, a statistically significant difference was observed in BOT and mean body dose between FF and FFF beams, with FFF beams showing superior performance. Considering all results, VMAT using 10 MV (FFF) is suggested for treating prostate cancer patients with SBRT. This offers the fastest delivery in addition to maintaining the highest plan quality.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Masculino , Humanos , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Dosagem Radioterapêutica , Radiometria , Órgãos em Risco/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS