RESUMO
Microbiologically Influenced Corrosion (MIC) poses a significant challenge to various industries, leading to substantial economic losses and potential safety hazards. Despite extensive research on the MIC resistance of various materials, there is a lack of studies focusing on High Chromium White Iron (HCWI) alloys, which are widely used in wear-resistant applications. This study addresses this knowledge gap by providing a comprehensive investigation of the MIC resistance of three HCWI alloys with varying chromium contents (22 wt%, 30.7 wt%, and 21 wt%) in the presence of Pseudomonas aeruginosa (P. Aeruginosa), a common bacterial species associated with MIC. The alloys were exposed to an artificial seawater medium inoculated with P.Aeruginosa for 14 days, and their corrosion behaviour was evaluated using electrochemical techniques, surface analysis, and microscopy. Electrochemical Impedance Spectroscopy (EIS) results revealed that the alloy with the highest chromium content (A2, 30.7 wt% Cr) exhibited superior MIC resistance compared to the other alloys (A1, 22 wt% Cr and M1, 21 wt% Cr). The enhanced performance of alloy A2 was attributed to the formation of a more stable and protective passive film, as well as the development of a more compact and less permeable biofilm. The EIS data, interpreted using equivalent circuit models, showed that alloy A2 had the highest charge transfer resistance and the lowest biofilm capacitance, indicating a more effective barrier against corrosive species. Bode plots further confirmed the superior corrosion resistance of alloy A2, with higher impedance values and phase angles at low frequencies compared to alloys A1 and M1. Scanning Electron Microscopy (SEM) and optical microscopy analyses corroborated these findings, showing that alloy A2 had the lowest pit density and size after 14 days of exposure. The insights gained from this study highlight the critical role of chromium content in the MIC resistance of HCWI alloys and have significant implications for the design and selection of materials for applications prone to microbial corrosion.
Assuntos
Biofilmes , Cromo , Pseudomonas aeruginosa , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/fisiologia , Corrosão , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Cromo/química , Ferro/metabolismo , Ferro/química , Espectroscopia Dielétrica , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Ligas de Cromo/químicaRESUMO
BACKGROUND: Marginal misfit and surface roughness of customized implant abutments is critical for restorative success. However, little is known about the comparison of misfit and surface roughness of CAD-CAM Zirconium oxide (ZrO), selective laser melting (SLM) Cobalt Chrome (CoCr) and preformed abutments. The aim of the study is to investigate the relation of misfit and micro-roughness of selective laser melting (SLM), preformed and CAD-CAM implant abutments. METHODS: Thirty internal connection, endosseous dental implants (Ø 4.0 mm x 10 mm, Dentium) were mounted in Polymethyl methacrylate vertically. Ten preformed Titanium alloy (Ti) abutments with 1 mm soft tissue height and Ø 4.5 mm were included as controls. Ten each of Y-TZP and SLM-CoCr, abutment/crowns were fabricated using CAD-CAM milling (CAD-CAM-ZrO) and SLM techniques. Surface micro-roughness (Ra) of the fabricated implant abutment/crown was evaluated with a 3D optical non-contact microscope. All implant restorations were torqued to implants (30 Ncm) using a Tohnichi BTGE digital torque gauge and were analyzed with Bruker micro-CT (Skyscan 1173) to detect micro-gaps at pre-selected points at implant abutment interface. The Ra and misfit data were compared using ANOVA, Tukey-Kramer, Kruskal-Wallis test and Pearson correlation (p < 0.05). RESULTS: Mean Ra among SLM CoCr abutments [0.88 (0.09) µm] were lower than CAD-CAM-ZrO and higher than preformed Ti abutments. Horizontal misfit among SLM-CoCr [45.43 (9.41) µm] and preformed Ti [36.87 (13.23) µm] abutments was not statistically different (p > 0.05). Misfit was significantly higher in Y-TZP samples compared to SLM-CoCr (p = 0.031) and preformed Ti abutments (p = 0.01). Preformed Ti abutments showed significantly lower misfit compared to SLM-CoCr abutments (p = 0.01). A positive linear correlation was observed between the surface roughness (Ra) and vertical misfit (r = 0.61, p < 0.05). CONCLUSION: SLM CoCr abutments showed rough surface compared to preformed Ti abutments, while horizontal misfit was comparable among SLM-CoCr and preformed abutments. Misfit was significantly greater in Y-TZP abutments, compared to SLM and preformed abutments. SLM abutment fabrication technique needs further improvement to provide better fit and surface topography.
Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Coroas , Dente Suporte , Projeto do Implante Dentário-Pivô , Lasers , Propriedades de Superfície , Titânio , Zircônio , Zircônio/química , Titânio/química , Ligas de Cromo/química , Humanos , Planejamento de Prótese Dentária , Adaptação Marginal DentáriaRESUMO
BACKGROUND: The fit of a metal-ceramic restoration is essential to its long-term durability. Regarding marginal and internal fit, there is not enough information about the technologies used in the production of metal-ceramic restorations. The aim of this in vitro study is to compare, both before and after porcelain firing, the marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations manufactured using casting, additive or subtractive computer-aided design, and computer-aided manufacturing techniques (CAD/CAM). METHODS: CAD/CAM were used to create 50 prepared maxillary first molar-shaped Co-Cr die models, which were randomly divided into 5 groups (n = 10). Cobalt-chrome copings were produced by casting (C), hard metal milling (HM), soft metal milling (SM), selective laser melting (SLM), and selective laser sintering (SLS) techniques. Before and after porcelain firing, discrepancies of the copings were measured using the silicone replica technique. The data obtained by measurements with a stereomicroscope at x80 magnification were analyzed statistically in the SPSS program. The ROBUST three-way analysis of variance (ANOVA) method was used to compare the discrepancy values. RESULTS: There were statistically significant differences among fabrication methods (P < .001). The HM method showed the highest discrepancy (90.1 µm), and the C (63 µm) method showed the lowest discrepancy in terms of the die model- crown fit. The C, SLS, and SM methods (63 µm; 61.6 µm; 67.7 µm) were statistically similar (P > .001). The highest discrepancy was observed on the occlusal area (87.1 µm), and the lowest discrepancy was observed on the axial area (47.7 µm) of the coping. Porcelain firing had a decrease in the discrepancy values (P = .001). CONCLUSION: All CAD/CAM techniques are appropriate for clinical use; selective laser sintering and soft milling can be the more recommended methods for the compatibility of metal-porcelain restorations, as they have lower discrepancy values than the SLM and HM methods.
Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Ligas Metalo-Cerâmicas , Ligas Metalo-Cerâmicas/química , Porcelana Dentária/química , Humanos , Técnica de Fundição Odontológica , Adaptação Marginal Dentária , Técnicas In Vitro , Ligas de Cromo/químicaRESUMO
OBJECTIVES: to assess the survival rates of removable partial dentures (RPDs) and identify factors impacting their longevity. METHODS: electronic health records were retrieved of patients aged ≥18 who received RPDs between 2010 - 2021 with a follow-up of ≥ three months. Data extracted included demographics, medical history, dental charting, periodontal screening and recording scores, prostheses details and related interventions, including new dentures/denture remakes, and maintenance. Multivariate Mixed-Effect Cox regression was performed to identify potential RPD survival risk factors. Reduced model selection was reached using a backward step-down by comparing the performance of these multivariable models using the ANOVA test. RESULTS: 1893 RPDs from 1246 patients were included, with a median follow-up of 21.8 months (range from 3 to 131.3 months). Three hundred and twelve patients received a maxillary RPD, 460 received a mandibular RPD, and the remaining 474 patients received both maxillary and mandibular RPDs. Metal-based RPDs had a median survival of 73 months (95%CI: 70 - 82) versus 45 months (95% CI: 37-67) for acrylic ones. Multivariable mixed effects Cox model showed that the lifespans of RPDs were longer amongst patients receiving more maintenance care within three months [Hazards Ratio (HR)=0.89 (0.83, 0.96)] and after three months [HR=0.53 (0.46, 0.61)] of denture delivery, patients wearing both maxillary and mandibular RPDs [HR=0.67 (0.52, 0.87)], and patients receiving metal-based RPDs [HR=0.31 (0.23, 0.42)]. CONCLUSIONS: Metal-based dentures, dual arch restoration, and increased maintenance positively impact the survival of RPDs. CLINICAL SIGNIFICANCE: Adapting consent and warranty practices is advised to reflect RPD performance variations.
Assuntos
Ligas de Cromo , Prótese Parcial Removível , Humanos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Adulto , Resinas Acrílicas , Planejamento de Dentadura , Falha de Restauração Dentária , Análise de Sobrevida , Fatores de Risco , Cobalto , Seguimentos , Retenção de Dentadura , Modelos de Riscos Proporcionais , MaxilaRESUMO
OBJECTIVES: To address the quality problems caused by high porosity in the preparation of dental cobalt-chrome alloy prosthetics based on selective laser melting (SLM) technology, we investigated the influence mechanism of different forming process parameters on the microstructure and properties of the materials. Moreover, the range of forming process parameters that can effectively reduce defects was precisely defined. METHODS: The effects of laser power, scanning speed, and scanning distance on the pore properties, surface roughness, and hardness of dental cobalt-chrome alloy were investigated by adjusting the printing parameters in the process of SLM. Through metallographic analysis, image analysis, and molten pool simulation, the pore formation mechanism was revealed, and the relationship between the porosity and energy density of SLM dental cobalt-chrome alloy was elucidated. RESULTS: When the linear energy density was higher than 0.18 J/mm, the porosity defect easily appeared at the bottom of the molten pool. When the laser energy density was lower than 0.13 J/mm, defects occurred in the gap of the molten pool due to insufficient melting of powder. In particular, when the linear energy density exceeded the threshold of 0.30 J/mm or was below 0.12 J/mm, the porosity increased significantly to more than 1%. In addition, we observed a negative correlation between free surface roughness and energy density and an inverse relationship between macroscopic hardness and porosity. CONCLUSIONS: On the basis of the conditions of raw materials and molding equipment used in this study, the key process parameters of SLM of molding parts with porosity lower than 1% were successfully determined. Specifically, these key parameters included the line energy density, which ranged from 0.13 J/mm to 0.30 J/mm, and the scan spacing should be strictly controlled below 90 µm.
Assuntos
Ligas de Cromo , Dureza , Lasers , Propriedades de Superfície , Porosidade , Teste de Materiais , Cobalto/química , Ligas DentáriasRESUMO
OBJECTIVES: This study aimed to evaluate the application of digital impression and resin model technology in removable partial dentures (RPD) for Kennedy classâ andâ ¡dentition defects. METHODS: Patients with Kennedy classâ orâ ¡dental defect were selected and grouped in accordance with the following denture production processes: digital impression/resin model/cast cobalt-chromium alloy framework group (group A), digital impression/resin model/laser printed titanium framework group (group B), alginate impression/plaster model/cast cobalt-chromium alloy framework group (group C), and alginate impression/plaster model/laser printed titanium framework group (group D), with 40 cases in each group. The final RPD was examined in place in the mouth, and the evaluation indicators included the retention force of clamp ring, the tightness of connector and base, and the accuracy of occlusion. The evaluation scores of each index were used for analysis on the Kruskal-Wallis rank-sum test. RESULTS: No statistically significant difference in the score of each index was found among the four groups in RPD. CONCLUSIONS: The cast cobalt-chromium alloy and laser-printed titanium framework RPD using digital impression and resin model can meet the clinical restoration requirements of patients with Kennedy classâ andâ ¡dentition defects.
Assuntos
Técnica de Moldagem Odontológica , Planejamento de Dentadura , Prótese Parcial Removível , Humanos , Ligas de Cromo , Titânio , Lasers , Desenho Assistido por ComputadorRESUMO
OBJECTIVES: This study aimed to evaluate the shear bond strength and failure behavior between cobalt-chromium (Co-Cr) alloy and different types of denture base resins (DBRs) over time. METHODS: Seventy-two disk-shaped specimens (8 mm in diameter and 2 mm in thickness) were manufactured using a selective laser melting technology-based metal 3D printer. Three types of DBRs were used: heat-cure (HEA group), cold-cure (COL group), and 3D-printable (TDP group) DBRs (n = 12 per group). Each DBR specimen was fabricated as a 5 mm × 5 mm × 5 mm cube model. The specimens of the TDP group were manufactured using a digital light processing technology-based 3D printer. Half of the DBRs were stored in distilled water at 37 °C for 24 h, whereas the remaining half underwent thermocycling for 10,000 cycles. Shear bond strength was measured using a universal testing machine; failure modes were observed, and metal surfaces were evaluated using energy dispersive spectrometry. RESULTS: The shear bond strength did not differ between the DBR types within the non-thermocycled groups. Contrarily, the TDP group exhibited inferior strength compared to the HEA group (P = 0.008) after thermocycling. All three types of DBRs exhibited a significant decrease in the shear bond strength and an increased tendency toward adhesive failure after thermocycling. CONCLUSIONS: The bond strength between 3D-printable DBRs and Co-Cr alloy was comparable to that of heat-and cold-cure DBRs before thermocycling. However, it exhibited a considerable weakening in comparison to heat-cure DBRs after simulated short-term use. CLINICAL SIGNIFICANCE: The application of 3D-printable DBR in metal framework-incorporated removable partial dentures may be feasible during the early phase of the treatment. However, its application is currently limited because the bond strength between the 3D-printable DBR and metal may weaken after short-term use. Further studies on methods to increase the bond strength between these heterogeneous materials are required.
Assuntos
Ligas de Cromo , Colagem Dentária , Materiais Dentários , Análise do Estresse Dentário , Bases de Dentadura , Teste de Materiais , Impressão Tridimensional , Resistência ao Cisalhamento , Ligas de Cromo/química , Materiais Dentários/química , Propriedades de Superfície , Humanos , Estresse Mecânico , Falha de Restauração DentáriaRESUMO
This virtual study was designed to evaluate the stress-deformation of a metal fixed partial dentures (FPDs) pontic under different loads using two different connectors. The STL file was generated for a RPD of two implant-supported restorations. The Co-Cr metal substructure was designed with two types of connector design. The pontic is connected to implant-supported crowns with square and round shape connectors. This study was designed for a cementless-retained implant-supported FPD. Finite element modeling (FEM) is used to assess the stress and deformation of the pontic within a metal substructure as the FEM might provide virtual values that could have laboratory and clinical relevance. The Co-Cr alloy mechanical properties like the Poisson ratio and modulus of elasticity were based on the parameters of the three-dimensional structure additive method. Nonparametric analyses (Mann-Whitney U test) was used. The use of square or round connectors often resulted in non-significant changes in stress, and deformation under either three or each loaded point on the occlusal surface of a pontic (P > 0.05). However, the deformation revealed distinct variations between loads of the three points compared to each loaded point (P ≤ 0.05). According to this study data, the pontic occlusal surface appears to be the same in stress and deformation under different loads depending on whether square or round connectors are used. While at the same connector designs, the pontic occlusal surface deformed significantly at three loaded points than it did at each point.
Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Análise de Elementos Finitos , Humanos , Ligas de Cromo/química , Planejamento de Dentadura , Análise do Estresse Dentário , Estresse MecânicoRESUMO
OBJECTIVES: To evaluate magnetic susceptibility artefacts produced by orthodontic wires on MRI and the influence of wire properties and MRI image sequences on the magnitude of the artefact. METHODS: Arch form orthodontic wires [four stainless steels (SS), one cobalt chromium (CC) alloy, 13 titanium (Ti) alloys] were embedded in a polyester phantom, and scanned using a 1.5-T superconducting magnet scanner with an eight-channel phased-array coil. All wires were scanned with T1-weighted spin echo (SE) and gradient echo (GRE) sequences according to the American Society for Testing and Materials (ASTM) F2119-07 standard. The phantom also scanned other eight sequences. Artefacts were measured using the ASTM F2119-07 definition and OsiriX software. Artefact volume was analysed according to metal composition, wire length, number of wires, wire thickness, and imaging sequence as factors. RESULTS: With SE/GRE, black/white artefacts volumes from all SS wires were significantly larger than those produced by CC and Ti wires (P < .01). With the GRE, the black artefacts volume was the highest with the SS wires. With the SE, the black artefacts volume was small, whereas white artefacts were noticeable. The cranio-caudal extent of the artefacts was significantly longer with SS wires (P < .01). Although a direct relationship of wire length, number of wires, and wire thickness with artefact volume was noted, these factors did not influence artefact extension in the cranio-caudal direction. CONCLUSIONS: Ferromagnetic/paramagnetic orthodontic wires create artefacts due to local alteration of magnetic field homogeneity. The SS-type wires produced the largest artefacts followed by CC and Ti.
Assuntos
Artefatos , Imageamento por Ressonância Magnética , Fios Ortodônticos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Titânio , Aço Inoxidável , Humanos , Ligas de Cromo/química , Ligas DentáriasRESUMO
PURPOSE: To characterize material changes that may occur in virgin cobalt-chromium (Co-Cr) alloy powder when it is blended with alloy powders that have been reused multiple times. MATERIALS AND METHODS: Initially, 20 kg of virgin Co-Cr powder was loaded into a laser-sintering device. The tensile test specimens were fabricated in the first (Group 1), fourth (Group 2), seventh (Group 3), tenth (Group 4), and thirteenth (Group 5) production cycles (N = 15). Prior to fabricating the specimens, powder alloy samples were collected from the powder bed for analysis. The tensile strength, elastic modulus, and percent elongation were calculated with tensile testing. Scanning electron microscopy and energy dispersive x-ray spectroscopy (SEM/EDS) and laser particle size distribution (LPSD) were used to analyze the alloy powder samples. The fracture surface of one tensile test specimen from each group was examined via SEM/EDS. One-way ANOVA followed by Dunnett T3 test was used for statistical analysis (α = .05). RESULTS: No difference was observed between groups in terms of tensile strength. A statistically significant difference was observed between Groups 1 and 2 in terms of percent elongation. Groups 2 and 4 were statistically significantly different in terms of both elastic modulus and percent elongation (P ≤ .05). SEM images of the powder alloy showed noticeable differences with increasing numbers of cycles. SEM images and the EDS analysis of the fractured specimens were in accordance with the strength data. CONCLUSIONS: Reusing Co-Cr alloy powder increased the particle size distribution. However, there was no correlation between increased cycle number and the mechanical properties of the powder.
Assuntos
Ligas de Cromo , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Pós , Resistência à Tração , Ligas de Cromo/química , Módulo de Elasticidade , Espectrometria por Raios X , Técnicas In Vitro , Propriedades de SuperfícieRESUMO
In this work, a sequential covalent immobilization of graphene oxide (GO) and hyaluronic acid (HA) is performed to obtain a biocompatible wear-resistant nanocoating on the surface of the biomedical grade cobalt-chrome (CoCr) alloy. Nanocoated CoCr surfaces were characterized by Raman spectroscopy and electrochemical impedance spectroscopy (EIS) in 3 g/L HA electrolyte. Tribocorrosion tests of the nanocoated CoCr surfaces were carried out in a pin on flat tribometer. The biological response of covalently HA/GO biofunctionalized CoCr surfaces with and without wear-corrosion processes was studied through the analysis of the proteome of macrophages. Raman spectra revealed characteristic bands of GO and HA on the functionalized CoCr surfaces. The electrochemical response by EIS showed a stable and protective behavior over 23 days in the simulated biological environment. HA/GO covalently immobilized on CoCr alloy is able to protect the surface and reduce the wear volume released under tribocorrosion tests. Unsupervised classification analysis of the macrophage proteome via hierarchical clustering and principal component analysis (PCA) revealed that the covalent functionalization on CoCr enhances the macrophage biocompatibility in vitro. On the other hand, disruption of the HA/GO nanocoating by tribocorrosion processes induced a macrophage proteome which was differently clustered and was distantly located in the PCA space. In addition, tribocorrosion induced an increase in the percentage of upregulated and downregulated proteins in the macrophage proteome, revealing that disruption of the covalent nanocoating impacts the macrophage proteome. Although macrophage inflammation induced by tribocorrosion of HA/GO/CoCr surfaces is observed, it is ameliorated by the covalently grafting of HA, which provides immunomodulation by eliciting downregulations in characteristic pro-inflammatory signaling involved in inflammation and aseptic loosening of CoCr joint arthroplasties. Covalent HA/GO nanocoating on CoCr provides potential applications for in vivo joint prostheses led a reduced metal-induced inflammation and degradation by wear-corrosion.
Assuntos
Ligas de Cromo , Grafite , Ácido Hialurônico , Macrófagos , Grafite/química , Ácido Hialurônico/química , Macrófagos/metabolismo , Macrófagos/efeitos dos fármacos , Animais , Camundongos , Corrosão , Ligas de Cromo/química , Proteômica , Células RAW 264.7 , Proteoma , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologiaRESUMO
BACKGROUND: There was no study evaluating the effects of an aspirin-free strategy in patients undergoing complex percutaneous coronary intervention (PCI). OBJECTIVES: The authors aimed to evaluate the efficacy and safety of an aspirin-free strategy in patients undergoing complex PCI. METHODS: We conducted the prespecified subgroup analysis based on complex PCI in the STOPDAPT-3 (ShorT and OPtimal duration of Dual AntiPlatelet Therapy after everolimus-eluting cobalt-chromium stent-3), which randomly compared low-dose prasugrel (3.75 mg/d) monotherapy to dual antiplatelet therapy (DAPT) with low-dose prasugrel and aspirin in patients with acute coronary syndrome or high bleeding risk. Complex PCI was defined as any of the following 6 criteria: 3 vessels treated, ≥3 stents implanted, ≥3 lesions treated, bifurcation with 2 stents implanted, total stent length >60 mm, or a target of chronic total occlusion. The coprimary endpoints were major bleeding events (Bleeding Academic Research Consortium 3 or 5) and cardiovascular events (a composite of cardiovascular death, myocardial infarction, definite stent thrombosis, or ischemic stroke) at 1 month. RESULTS: Of the 5,966 study patients, there were 1,230 patients (20.6%) with complex PCI. Regardless of complex PCI, the effects of no aspirin relative to DAPT were not significant for the coprimary bleeding (complex PCI: 5.30% vs 3.70%; HR: 1.44; 95% CI: 0.84-2.47; P = 0.18 and noncomplex PCI: 4.26% vs 4.97%; HR: 0.85; 95% CI: 0.65-1.11; P = 0.24; P for interaction = 0.08) and cardiovascular (complex PCI: 5.78% vs 5.93%; HR: 0.98; 95% CI: 0.62-1.55; P = 0.92 and noncomplex PCI: 3.70% vs 3.10%; HR: 1.20; 95% CI: 0.88-1.63; P = 0.25; P for interaction = 0.48) endpoints without significant interactions. CONCLUSIONS: The effects of the aspirin-free strategy relative to standard DAPT for the cardiovascular and major bleeding events were not different regardless of complex PCI. (ShorT and OPtimal duration of Dual AntiPlatelet Therapy after everolimus-eluting cobalt-chromium stent-3 [STOPDAPT-3]; NCT04609111).
Assuntos
Aspirina , Doença da Artéria Coronariana , Esquema de Medicação , Stents Farmacológicos , Terapia Antiplaquetária Dupla , Everolimo , Hemorragia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Cloridrato de Prasugrel , Desenho de Prótese , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Masculino , Fatores de Tempo , Feminino , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Fatores de Risco , Cloridrato de Prasugrel/administração & dosagem , Cloridrato de Prasugrel/efeitos adversos , Cloridrato de Prasugrel/uso terapêutico , Everolimo/administração & dosagem , Everolimo/efeitos adversos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Ligas de Cromo , Medição de Risco , Quimioterapia CombinadaRESUMO
Cobalt-Chromium (CoCr) alloys are currently used for various cardiovascular, orthopedic, fracture fixation, and dental implants. A variety of processes such as casting, forging, wrought processing, hot isostatic pressing, metal injection molding, milling, selective laser melting, and electron beam melting are used in the manufacture of CoCr alloy implants. The microstructure and precipitates (carbides, nitrides, carbonitrides, and intermetallic compounds) formed within the alloy are primarily determined by the type of manufacturing process employed. Although the effects of microstructure and precipitates on the physical and mechanical properties of CoCr alloys are well reviewed and documented in the literature, the effects on corrosion resistance and biocompatibility are not comprehensively reviewed. This article reviews the various processes used to manufacture CoCr alloy implants and discusses the effects of manufacturing processes on corrosion resistance and biocompatibility. This review concludes that the microstructure and precipitates formed in the alloy are unique to the manufacturing process employed and have a significant impact on the corrosion resistance and biocompatibility of CoCr alloys. Additionally, a historical and scientific overview of corrosion and biocompatibility for metallic implants is included in this review. Specifically, the failure of CoCr alloys when used in metal-on-metal bearing surfaces of total hip replacements is highlighted. It is recommended that the type of implant/application (orthopedic, dental, cardiovascular, etc.) should be the first and foremost factor to be considered when selecting biomaterials for medical device development.
Assuntos
Ligas de Cromo , Teste de Materiais , Humanos , Corrosão , Ligas de Cromo/química , Animais , Materiais Biocompatíveis/química , Próteses e ImplantesRESUMO
PURPOSE: The purpose of this systematic review and meta-analysis was to compare the influence of fabrication method (conventional, subtractive, and additive procedures) and manufacturing trinomial (technology, printer, and material combination) on the marginal and internal fit of cobaltchromium (Co-Cr) tooth-supported frameworks. MATERIALS AND METHODS: An electronic systematic review was performed in five data bases: MEDLINE/PubMed, Embase, World of Science, Cochrane, and Scopus. Studies that reported the marginal and internal discrepancies of tooth-supported Co-Cr additive manufacturing (AM) frameworks were included. Two authors independently completed the quality assessment of the studies by applying the Joanna Briggs Institute Critical Appraisal Checklist for Quasi-Experimental Studies. A third examiner was consulted to resolve lack of consensus. RESULTS: A total of 31 articles were included and classified based on the evaluation method: manufacturing accuracy, the dual- or triple-scan method, stereomicroscope, optical coordinate measurement machine, microCT, profilometer, and silicone replica. Six subgroups were created: 3D Systems, Bego, Concept Laser, EOS, Kulzer, and Sisma. Due to the heterogeneity and limited data available, only the silicone replica group was considered for meta-analysis. The metaanalysis showed a mean marginal discrepancy of 91.09 µm (I2 = 95%, P < .001) in the conventional group, 77.48 µm (I2 = 99%, P < .001) in the milling group, and 82.92 µm (I2 = 98%, P < .001) in the printing group. Additionally, a mean internal discrepancy of 111.29 µm (I2 = 94%, P < .001) was obtained in the conventional casting group, 121.96 µm (I2 = 100%, P < .001) in the milling group, and 121.25 µm (I2 = 99%, P < .001) in the printing group. CONCLUSIONS: Manufacturing method and selective laser melting (SLM) metal manufacturing trinomial did not impact the marginal and internal discrepancies of Co-Cr frameworks for the fabrication of tooth-supported restorations.
Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Humanos , Ligas de Cromo/química , Adaptação Marginal Dentária , Impressão Tridimensional , Planejamento de Dentadura , Planejamento de Prótese Dentária , Tecnologia Odontológica , Materiais Dentários/químicaRESUMO
BACKGROUND: Modular dual mobility (DM) bearings have a junction between a cobalt chrome alloy (CoCrMo) liner and titanium shell, and the risk of tribocorrosion at this interface remains a concern. The purpose of this study was to determine whether liner malseating and liner designs are associated with taper tribocorrosion. METHODS: We evaluated 28 retrieved modular DM implants with a mean in situ duration of 14.6 months (range, 1 to 83). There were 2 manufacturers included (12 and 16 liners, respectively). Liners were considered malseated if a distinct divergence between the liner and shell was present on postoperative radiographs. Tribocorrosion was analyzed qualitatively with the modified Goldberg Score and quantitatively with an optical coordinate-measuring machine. An acetabular shell per manufacturer was sectioned for metallographic analysis. RESULTS: There were 6 implants (22%) that had severe grade 4 corrosion, 6 (22%) had moderate grade 3, 11 (41%) had mild grade 2, and 5 (18.5%) had grade 1 or no visible corrosion. The average volumetric material loss at the taper was 0.086 ± 0.19 mm3. There were 7 liners (25%) that had radiographic evidence of malseating, and all were of a single design (P = .01). The 2 liner designs were fundamentally different from one another with respect to the cobalt chrome alloy type, taper surface finish, and shape deviations. Malseating was an independent risk factor for increased volumetric material loss (P = .017). CONCLUSIONS: DM tribocorrosion with quantifiable material loss occurred more commonly in malseated liners. Specific design characteristics may make liners more prone to malseating, and the interplay between seating mechanics, liner characteristics, and patient factors likely contributes to the shell/liner tribocorrosion environment. LEVEL OF EVIDENCE: Level III.
Assuntos
Artroplastia de Quadril , Ligas de Cromo , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Corrosão , Artroplastia de Quadril/instrumentação , Idoso , Pessoa de Meia-Idade , Feminino , Masculino , Idoso de 80 Anos ou mais , Titânio , Adulto , Estudos RetrospectivosRESUMO
AIMS: The objectives of the study were to compare the adaptation of presintered zirconia and cobalt- chromium prostheses using microcomputed tomography (µCT), scanning electron microscopy (SEM), and stereomicroscope (SM). MATERIALS AND METHODS: Twenty-four fixed dental prostheses (FDPs) were fabricated on metal abutments, duplicated from maxillary first premolar and first molar prepared on a typodont model. Teeth were reduced to obtain chamfer of 1.2 mm and reduction occlusaly of 2 mm occlusal. Scanning of the abutments was done with random assignment to two groups receiving the FDPs made from soft-milled Co-Cr (n = 12) and zirconia (n = 12). Marginal and internal gaps were assessed using three evaluation techniques (X-ray microcomputer tomography, SEM, and stereomicroscopy). STATISTICAL ANALYSIS USED: Comparison of the results was made using Levene and analysis of variance tests (α =0.05). RESULTS: Irrespective of the material tested, statistical differences were found between the measuring techniques (P = 0.001 overall); the obtained mean gaps were for CT scan (92.60 ± 13.31), for SEM (101.92 ± 23.03), and for SM (113.44 ± 14.68): the multiple comparisons between techniques found a significant difference between CT and SM (P < 0.001), and SEM and SM (P = 0.025). When materials were compared within each measuring technique, Co-Cr showed lower values compared to zirconia in SEM (P < 0.001) and Stereo (P = 0.049); similar results were found in CT. CONCLUSIONS: Results values differed with the chosen measuring technique. Co-Cr prostheses had a better fit than zirconia prostheses in SEM and Stereo. µCT showed comparable results to SEM, smaller than SM results.
Assuntos
Ligas de Cromo , Microscopia Eletrônica de Varredura , Microtomografia por Raio-X , Zircônio , Zircônio/química , Microtomografia por Raio-X/métodos , Ligas de Cromo/química , Humanos , Planejamento de Prótese Dentária/métodosRESUMO
OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.
Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Teste de Materiais , Porcelana Dentária/química , Humanos , Dente Suporte , Cerâmica/química , Propriedades de Superfície , Materiais Dentários/química , Adaptação Marginal Dentária , Ligas de Cromo/químicaRESUMO
STATEMENT OF PROBLEM: The surface topography of metal substrate can affect its bond to porcelain. A neodynium-doped yttrium aluminum garnet (Nd:YAG) laser has been introduced to modify the metal surface topography and improve porcelain bond strength. However, studies on the effect of laser etching on metal to porcelain bond strength are lacking. PURPOSE: The purpose of this in vitro study was to determine the effect of Nd:YAG laser etching on the surface roughness and wettability of and the porcelain bond strength to cobalt chromium (Co-Cr) substrate fabricated by milling and direct metal laser sintering (DMLS). MATERIAL AND METHODS: Thirty-two 0.5×3×25-mm Co-Cr specimens were fabricated by milling soft Co-Cr (M group) and DMLS Co-Cr metal powder (DML group). The surface topography of representative specimens from each study group was assessed under a scanning electron microscope (SEM) and an atomic force microscope (AFM). All specimens were assessed for surface roughness using a contact profilometer, and for wettability with a contact angle goniometer. Half of the specimens of each study group (n=8) were subjected to surface laser etching by using a Nd:YAG laser. The specimens subjected to etching were assessed again for surface topography and wettability. All specimens in both study groups were veneered with porcelain. The porcelain bond strength was tested with a 3-point bend test in a universal testing machine. The results were statistically analyzed with 2-way ANOVA test followed by the post hoc Tukey test for pairwise comparisons (α=.05). RESULTS: After etching, the M group had a higher mean ±standard deviation Ra and Rz of 2.9 ±0.6 and 17.7 ±3.2 µm and significantly better wettability and bond strength of 79 ±6 and 52 ±13 MPa. In contrast, after etching, the DMLS group had a significantly lower Ra and Rz of 7.9 ±2.4 and 41.8 ±9.3 µm and significantly lower wettability and bond strength of 87 ±4 and 70 ±10 MPa. The DMLS group had a significantly higher roughness and bond strength than the M group before and after laser etching. The SEM and AFM showed different surface topography in the study groups. CONCLUSIONS: The manufacturing process of Co-Cr substrate had a significant effect on surface characteristics and porcelain bond strength. Laser etching improved the surface topography and bond strength of milled Co-Cr but not of DMLS Co-Cr.
Assuntos
Ligas de Cromo , Colagem Dentária , Porcelana Dentária , Lasers de Estado Sólido , Propriedades de Superfície , Ligas de Cromo/química , Porcelana Dentária/química , Colagem Dentária/métodos , Microscopia Eletrônica de Varredura , Corrosão Dentária/métodos , Molhabilidade , Microscopia de Força Atômica , Teste de Materiais , Análise do Estresse Dentário , Humanos , Técnicas In VitroRESUMO
BACKGROUND: Data on bacterial adhesion to cerclage cables are sparse. We aimed to compare 5 cerclage products for methicillin-resistant Staphylococcus aureus (MRSA) adhesion to determine the claim: Are nonmetallic polymer cables more resistant to bacterial adhesion than common metallic wires and cables? METHODS: The following 5 cerclage products were compared: (1) monofilament stainless steel (SS) wires; (2) multifilament SS cables; (3) multifilament cobalt chrome cables; (4) multifilament Vitallium alloy (cobalt-chrome-molybdenum [Co-Cr-Mo]) cables; and (5) multifilament nonmetallic polymer cables. Each was cut into 2 cm lengths and placed into 12-well plates. Of the wells, 5 were wire or cables in trypticase soy broth with MRSA, with the remaining wells being appropriate controls incubated for 24 hours at 37° C and 5% CO2 with shaking. Wires and cables were prepared and randomly imaged via scanning electron microscopy, with bacterial counts performed on 3 images of 3 different wires or cables per study group. The scanning electron microscopy technician and counting investigator were blinded. Additionally, SS wire and polymer cables were analyzed by microcalorimetry for metabolic activity and bacterial load. RESULTS: Bacterial attachment differed significantly between study groups in the middle section (P = .0003). Post hoc comparison showed no difference between groups individually (all P > .05) apart from polymer cables (median 551 bacteria) having significantly increased attached bacteria compared to the Vitallium alloy cable (157, P = .0004), SS cable (101, P = .0004), and SS wire (211, P = .0004). There was no difference between polymer and cobalt chrome cables (133, P = .056). Microcalorimetry supported these results, as polymer cables had a shorter time to max heat flow (6.2 versus 7.5 hours, P = .006), increased max heat flow (117 versus 64 uW, P = .045), and increased colony-forming units, indicating an increased bacterial load compared to SS wires. CONCLUSIONS: This in vitro study demonstrated that polymer cables have increased MRSA adhesion compared to common metallic wires and cables. Future studies are necessary to confirm the translation of increased bacterial adherence on polymer cables to increased rates of orthopaedic infections.