RESUMO
BACKGROUND AND OBJECTIVE: Botulinum toxins, originally used for facial rejuvenation, have emerged as a promising tool for sculpting and refining contours for both the face and body. METHODS: The peer-reviewed literature on neuromodulator contouring treatments was analyzed, with a particular emphasis on studies and case reports involving the use of botulinum toxin type A. RESULTS: Modification of face, neck, shoulder, arm, and calf contour has been reported. Treatment and dosing protocols vary with the strength and depth of the target muscle. Regional effects of neuromodulator treatment begin to appear approximately 2 weeks after injection and are often most prominent at the 70- to 90-day time point. Although treatments are generally well tolerated, short-term muscle weakness and other side effects may occur. CONCLUSION: The use of neuromodulators to enhance facial and body contours has demonstrated efficacy, but further research is needed to validate their use and explore the full potential of this intervention through larger randomized controlled trials. The application of neuromodulators as a minimally invasive tool to address the rising demand for nonsurgical body sculpting represents a promising frontier in aesthetics.
Assuntos
Toxinas Botulínicas Tipo A , Neurotransmissores , Humanos , Toxinas Botulínicas Tipo A/administração & dosagem , Toxinas Botulínicas Tipo A/efeitos adversos , Neurotransmissores/administração & dosagem , Neurotransmissores/uso terapêutico , Técnicas Cosméticas , Face , Envelhecimento da Pele/efeitos dos fármacos , Fármacos Neuromusculares/administração & dosagem , Fármacos Neuromusculares/efeitos adversos , Contorno Corporal/métodos , Contorno Corporal/efeitos adversos , RejuvenescimentoRESUMO
OBJECTIVES: This study aims to assess the thermal safety profile of the BeShape One Device, a noninvasive, high-intensity, non-focused ultrasound device designed for reducing waist circumference. This device possesses several features that distinguish it from other commercial ultrasound-based fat reduction devices. The study focuses on evaluating temperature-related physiological changes through thermal safety analysis and histopathology in a swine model. MATERIALS AND METHODS: The study utilized three types of applicators-active, demo, and modified-to comprehensively assess the device's impact on various skin layers. Five female Large White X Landrace swine were involved in the study, and the BeShape One Device was applied to designated treatment sites using a specific treatment protocol. The assessment included clinical observations, skin reaction evaluations, gross pathology, histopathological analyses, and advanced temperature measurement techniques, including needle thermocouples, thermal cameras, COMSOL modeling, and CEM43 analysis. RESULTS: Clinical observations indicated the animals' overall well-being throughout the study. Skin reactions, including erythema, edema, bruising, and crust formation, were temporary and resolved over time. Gross pathology revealed no treatment-related pathologies, except for a discoloration related to a tattoo procedure. Histopathological analyses at 30 and 90 days posttreatment demonstrated an absence of heat-related lesions in skin layers. Needle thermocouples and thermal camera measurements supported the device's ability to maintain consistent thermal homogeneity. COMSOL modeling and CEM43 analysis predicted no thermal damage to the skin, confirming the safety of the BeShape One Device. CONCLUSIONS: Under the experimental conditions, the BeShape One Device demonstrated a favorable safety profile. Clinically and histopathologically, no adverse effects were observed. The device's ability to achieve thermal homogeneity in skin layers was validated through advanced temperature measurement techniques. COMSOL modeling and CEM43 analysis further supported the conclusion that the device is safe, making it a promising option for noninvasive body contouring procedures.
Assuntos
Contorno Corporal , Animais , Feminino , Suínos , Contorno Corporal/instrumentação , Contorno Corporal/métodos , Contorno Corporal/efeitos adversos , Modelos Animais , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/efeitos adversosRESUMO
BACKGROUND/AIM: Various devices for non-invasive body shape correction are being developed along with the growth of the beauty industry. Radiofrequency (RF) can selectively reduce subcutaneous fat without causing skin damage. The efficacy of the procedure can be improved by applying RF to a large area simultaneously with multiple handpieces. This study evaluated the safety and efficacy of a new RF device with multi-channel handpieces. MATERIALS AND METHODS: In ex vivo experiments, the RF device was used to treat porcine tissue comprising the skin, subcutaneous, and muscle layers. The device's safety was evaluated by temperature measurements of porcine tissue and histological analysis. In in vivo experiments, the dorsal skin of pigs was treated with the RF device. The safety and efficacy of the device were evaluated by measuring the skin temperature, subcutaneous fat layer thickness, and conducting histological analysis. RESULTS: The skin temperature did not exceed the set temperature during treatment, and skin damage was not observed in histologic analysis in both ex vivo and in vivo experiments. In in vivo experiments, the subcutaneous fat layer thickness and subcutaneous lipocyte size were decreased after treatment. In addition, the fibrous tissue between subcutaneous lipocytes was increased in the RF treatment group compared with the non-treatment group. CONCLUSION: The RF device used in this study effectively reduced the size of subcutaneous lipocytes and increased fibrous tissue without skin damage. Therefore, the safe and effective use of this device for non-invasive fat reduction may be possible in clinical settings.
Assuntos
Gordura Subcutânea , Animais , Suínos , Gordura Subcutânea/citologia , Terapia por Radiofrequência/métodos , Pele/efeitos da radiação , Contorno Corporal/métodos , Contorno Corporal/instrumentação , Tecido Adiposo/citologia , Temperatura Cutânea/efeitos da radiaçãoRESUMO
Existe en la práctica diaria de los cirujanos plásticos una búsqueda continua de mejores alternativas técnicas para el tratamiento de las deformidades del contorno abdominal. La LADE (Lipoabdominoplastia con defi nición anatómica) da un paso más adelante de la técnica LAP tradicional. Esta técnica incorpora los principios de resaltar la defi nición de la musculatura abdominal, consiguiendo resultados más naturales y con menos estigmas de una intervención quirúrgica. Los resultados estéticos son mucho más armoniosos, con un verdadero aspecto abdominal rejuvenecido. Logramos reducir la morbilidad preservando los vasos sanguíneos perforantes y suspendiendo la fascia de Scarpa. Una correcta selección del paciente asociado a la estandarización de esta técnica hace que el procedimiento sea seguro y reproducible
There is a continuous search for better technical alternatives for the treatment of abdominal contour deformities in the practice of plastic surgeons. LADE Lipoabdominoplasty with Anatomical Defi nition is a step ahead of the traditional LAP technique. This technique incorporated the principles of highlighting the defi nition of the abdominal musculature, achieving more natural results with fewer reminders of a surgical intervention. The aesthetic results are much harmonious, with a true abdominal rejuvenated appearance. We can reduce morbidity by preservation of perforating blood vessels and suspension of Scarpa's fascia. The correct selection of the patient associated with the standardization of this technique makes the procedure safe and reproducible
Assuntos
Lipectomia/métodos , Fáscia , Contorno Corporal/métodos , Lipoabdominoplastia/métodosRESUMO
BACKGROUND: Complications after abdominoplasty remain an unsolved issue in body contouring surgery. The antifibrinolytic drug tranexamic acid (TXA) has gained increasing recognition as a valuable pharmacologic agent within plastic surgery. The aim of this study was to investigate the influence of intravenously administered TXA on complications and patient safety after abdominoplasty. METHODS: Within this retrospective single-center study, patients who underwent abdominoplasty and received intravenous TXA were selected and compared to randomly selected patients who underwent abdominoplasty without administration of TXA. The patient population was divided into two study groups (TXA vs no TXA). Demographic and surgical data as well as complications were evaluated and compared. Appropriate statistical analysis was performed. RESULTS: Fifty-seven female and 3 male patients with a median age of 38 years and a mean BMI of 25.6 ± 3.3 kg/m2 were included in the study. Except smoking history, demographic data showed no statistically significant differences between both groups. The most common complication was seroma formation (n = 16; 23.9%), and its occurrence was statistically significantly lower in the TXA group (p = 0.023). Furthermore, postoperative seroma aspiration was performed in statistically significant lower numbers in the TXA group (p < 0.05). No thromboembolic events or seizures were observed. DISCUSSION: The outcomes of this study showed that the intravenous administration of TXA leads to a significant reduction of seroma formation and postoperative seroma aspiration after abdominoplasty. Simultaneously, no adverse thromboembolic events were detected. Hence we would recommend administration of TXA in body contouring surgery to decrease the incidence of seroma formation. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Abdominoplastia , Antifibrinolíticos , Contorno Corporal , Complicações Pós-Operatórias , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/uso terapêutico , Ácido Tranexâmico/administração & dosagem , Abdominoplastia/efeitos adversos , Abdominoplastia/métodos , Feminino , Estudos Retrospectivos , Adulto , Masculino , Antifibrinolíticos/administração & dosagem , Antifibrinolíticos/uso terapêutico , Contorno Corporal/métodos , Contorno Corporal/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Pessoa de Meia-Idade , Resultado do Tratamento , Medição de Risco , Seroma/prevenção & controle , Seroma/etiologia , Seroma/epidemiologiaRESUMO
BACKGROUND: The increasing number of fatalities caused by gluteal fat grafting is concerning; thus, there is a need to determine ways to obtain the ideal aesthetic effect while ensuring a safe operation. In this study, three-dimensional (3D) measurements combined with B-ultrasound were used to evaluate the effect of gluteal fat augmentation in Asians, whose safety and effectiveness were confirmed using quantitative data. METHODS: Thirty-five consecutive female patients were evaluated in this prospective clinical study. All patients underwent B-ultrasound-assisted gluteal fat augmentation on the subcutaneous plane alone. 3D imaging and B-ultrasound analysis of the adipose tissue thickness in the gluteal region were performed preoperatively and at 1 week, 3 months and 6 months post-operatively. RESULTS: The waist circumference of the patients decreased, gluteal circumference and length of the gluteal crease increased and average waist-to-hip ratio improved from 0.78 to 0.74. At 3 months and 6 months post-operatively, the adipose tissue thickness decreased by 5.1% and 15.1%, respectively. The fat retention rates calculated using 3D imaging measurements at 3 months and 6 months post-operatively were 77.9% and 64.7%, respectively. According to the BODY-Q scale scores, patients reported a high level of satisfaction post-operatively. CONCLUSIONS: B-ultrasound guidance can effectively prevent the occurrence of fatal fat embolism during gluteal fat grafting and maximise the augmentation effect. The quantitative data obtained using 3D measurements and B-ultrasound confirmed the safety and effectiveness of fat injections for gluteal augmentation under B-ultrasound guidance.
Assuntos
Tecido Adiposo , Povo Asiático , Imageamento Tridimensional , Humanos , Nádegas/diagnóstico por imagem , Nádegas/cirurgia , Feminino , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Tecido Adiposo/transplante , Tecido Adiposo/diagnóstico por imagem , Ultrassonografia/métodos , Contorno Corporal/métodos , Relação Cintura-Quadril , Ultrassonografia de Intervenção/métodos , Resultado do TratamentoRESUMO
This study investigates the application of cavitation in non-invasive abdominal fat reduction and body contouring, a topic of considerable interest in the medical and aesthetic fields. We explore the potential of cavitation to alter abdominal fat composition and delve into the optimization of fat prediction models using advanced hyperparameter optimization techniques, Hyperopt and Optuna. Our objective is to enhance the predictive accuracy of abdominal fat dynamics post-cavitation treatment. Employing a robust dataset with abdominal fat measurements and cavitation treatment parameters, we evaluate the efficacy of our approach through regression analysis. The performance of Hyperopt and Optuna regression models is assessed using metrics such as mean squared error, mean absolute error, and R-squared score. Our results reveal that both models exhibit strong predictive capabilities, with R-squared scores reaching 94.12% and 94.11% for post-treatment visceral fat, and 71.15% and 70.48% for post-treatment subcutaneous fat predictions, respectively. Additionally, we investigate feature selection techniques to pinpoint critical predictors within the fat prediction models. Techniques including F-value selection, mutual information, recursive feature elimination with logistic regression and random forests, variance thresholding, and feature importance evaluation are utilized. The analysis identifies key features such as BMI, waist circumference, and pretreatment fat levels as significant predictors of post-treatment fat outcomes. Our findings underscore the effectiveness of hyperparameter optimization in refining fat prediction models and offer valuable insights for the advancement of non-invasive fat reduction methods. This research holds important implications for both the scientific community and clinical practitioners, paving the way for improved treatment strategies in the realm of body contouring.
Assuntos
Gordura Abdominal , Aprendizado de Máquina , Humanos , Contorno Corporal/métodos , Masculino , Feminino , Gordura Intra-Abdominal , AdultoRESUMO
BACKGROUND: With the rise in interest and demand for body contouring, beauty devices have continuously developed. Suction can aid in increasing the rate of fat breakdown by inducing a massage-like effect, thereby increasing blood flow. Moreover, radiofrequency (RF) can boost fibroblast activity and help reduce cellulite. In addition, electrical muscle stimulation (EMS) can use electrical stimulation to induce muscle contraction, leading to an athletic, and skin elasticity-increasing effect. AIMS: This study aimed to assess the effects of body contouring, such as cellulite and swelling, in healthy Korean women to objectively prove the efficacy of an at-home beauty device equipped with suction, RF, and EMS functions. METHODS: For 8 weeks, 21 participants used the at-home beauty device 3 days a week on their abdomen, thighs, and left calf. Validity assessments and subjective surveys were conducted at 4 and 8 weeks, including the first visit. RESULTS: The results of the validity assessments revealed that cellulite, swelling, elasticity, femoral skin texture, and dermal density were significantly (p < 0.05) improved in the experimental group compared with those at the baseline. CONCLUSIONS: The results of this study demonstrate that the combination of suction, RF, and EMS function is effective for body skin, fat, and body shape management. For better body-contouring effects, combining the beauty device with regular exercise and healthy eating habits is recommended.
Assuntos
Contorno Corporal , Humanos , Feminino , Contorno Corporal/métodos , Contorno Corporal/instrumentação , Adulto , Sucção/instrumentação , Elasticidade/efeitos da radiação , Celulite/terapia , Coxa da Perna , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Perna (Membro) , Adulto Jovem , Terapia por Radiofrequência/instrumentação , Pele/efeitos da radiação , Edema/etiologia , Edema/prevenção & controle , República da CoreiaRESUMO
INTRODUCTION: The Brazilian Butt Lift (BBL) is a safe technique that entails body reshaping through buttock augmentation using autologous fat transfer. METHOD: Between 2018 and 2022, 3000 patients underwent surgery. Each procedure commenced with the patient in supine position, starting with abdominal liposuction, followed by fat transfer to hips. Subsequently, the patient was repositioned to a prone stance. Liposuction of the back and waist ensued, concluding the surgery with fat transfer to the buttocks. Stringent precautions were implemented to ensure the safety of the patient throughout the procedure. RESULTS: Eighty-six percent of patients express satisfaction with their outcomes, while seventy percent of the transferred fat calls survive in the buttocks. One serious complication and some minor complications have been encountered and effectively managed through conservative measures. CONCLUSION: BBL proves to be a safe and satisfactory surgery when performed by experienced surgeons who adhere to fundamental principles. LEVEL OF EVIDENCE 3: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Contorno Corporal , Lipectomia , Satisfação do Paciente , Humanos , Nádegas/cirurgia , Brasil , Feminino , Lipectomia/métodos , Adulto , Contorno Corporal/métodos , Contorno Corporal/efeitos adversos , Pessoa de Meia-Idade , Satisfação do Paciente/estatística & dados numéricos , Masculino , Tecido Adiposo/transplante , Resultado do Tratamento , Estética , Estudos Retrospectivos , Estudos de Coortes , Posicionamento do Paciente , Medição de Risco , Transplante AutólogoRESUMO
INTRODUCTION: Body contouring procedures are commonly performed in the United States for patients seeking to sculpt specific areas of their bodies. The aim of this study was to provide an updated analysis of the factors that influence medical malpractice litigation surrounding body contouring surgery. METHODS: The following terms were used to search the Westlaw Campus Legal research Database for cases with earliest documentation after January 2013: ("contouring" OR "abdominoplasty" OR "liposuction" OR "tummy tuck" OR "body lift" OR "thigh lift" OR "arm lift" OR "brachioplasty" OR "thighplasty" OR "lipectomy" OR "panniculectomy") AND "surgery" AND "medical malpractice." Cases were only included if there was a complaint of medical malpractice subsequent to a body contouring procedure, and details of the cases were provided. Information was collected on the location of the lawsuit, the earliest year of available case documentation, patient demographics, procedure(s) performed, alleged injury, specialty involvement, and verdicts. RESULTS: A total of 32 cases were included in the study. Most of the patients involved in the cases were women (n = 30, 93.8%) and alive (n = 28, 87.5%). New York state had the most cases (n = 7, 21.9%). Abdominoplasty (56.3%), liposuction (53.1%), and buttock augmentations (15.6%) were the most common procedures. Plastic surgeons were involved in 93.8% (n = 30) of the cases, and anesthesia, emergency medicine, dermatology, and oncology were also involved. Claims of malpractice most often discussed negligent technique (71.9%) and poor postoperative management (62.5%). Common postoperative complications were infection/sepsis (40.6%), scarring (31.3%), and emotional distress/prolonged pain (31.3%). One available ruling was in favor of the plaintiff. CONCLUSION: Although many of the cases in this analysis cited negligent technique, none were founded in their argument. Because involvement in these cases can place a burden on attending physicians, clear expectations of postoperative infections, scarring, and prolonged pain should be addressed during the informed consent process.
Assuntos
Contorno Corporal , Imperícia , Cirurgiões , Humanos , Feminino , Estados Unidos , Masculino , Contorno Corporal/efeitos adversos , Cicatriz , Dor , Bases de Dados FactuaisRESUMO
BACKGROUND: An accumulation of adipose tissue on the lateral abdomen (flanks) coupled with muscle deconditioning negatively affects core stability, muscular balance, and the intrinsic strength essential for maintaining optimal body mechanics and posture. This lateral fat accumulation and diminution of muscle result in an unfavorable abdominal profile and present challenges in finding appropriately fitting attire. OBJECTIVES: The aim of this study was to explore the effectiveness and safety of the simultaneous application of high-intensity focused electromagnetic (HIFEM) therapy and synchronized radiofrequency for sculpting the lateral abdomen. METHODS: All patients were scheduled to undergo four 30-minute treatments at approximately weekly intervals and then subsequent follow-up visits at 1 month and 3 months after the last treatment. The primary evaluation assessed changes in the oblique muscles, adipose tissue thickness, and cross-sectional area (CSA) by MRI performed at baseline and follow-ups. The secondary outcomes included digital photographs of the treated areas, a Subject Satisfaction Questionnaire, and a Therapy Comfort Questionnaire. Adverse events and side effects were monitored throughout the study duration. RESULTS: The muscle tissue showed a substantial increase in thickness (+27.2%) and CSA (+29.0%). The adipose tissue measurements showed a decrease of -30.5% in CSA and -28.8% in thickness. As secondary outcomes, 81.8% of patients reported feeling more toned, and 84.9% of patients found the treatment comfortable and reported less than mild pain. CONCLUSIONS: Based on the evaluation, the study suggests that the simultaneous application of HIFEM and synchronized radiofrequency is safe and effective for reducing adipose tissue and strengthening muscle in the area of the lateral abdomen.
Assuntos
Imageamento por Ressonância Magnética , Satisfação do Paciente , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Resultado do Tratamento , Contorno Corporal/métodos , Contorno Corporal/efeitos adversos , Adulto Jovem , Músculos Abdominais/diagnóstico por imagem , Estudos ProspectivosRESUMO
BACKGROUND: Patients with obesity who undergo bariatric surgery achieve sustained weight loss but are often left with excess skin folds that cause functional and psychological deficits. To remove excess skin, patients can undergo postbariatric BCS; however, cost and lack of insurance coverage present a significant barrier for many patients. OBJECTIVES: This study aimed to characterize the financial impact of treatment on all patients who received bariatric surgery and to compare between those receiving only bariatric surgery and those with postbariatric BCS. SETTING: Email-based survey study at an urban tertiary care center. METHODS: Surveys that included the COST-FACIT were sent to patients with a history of bariatric surgery and/or post-bariatric BCS. RESULTS: One hundred and five respondents completed the survey, of which 19 reported having postbariatric BCS. Patients with postbariatric BCS had slightly higher COST scores than those receiving bariatric surgery only, but this difference was not significant (15.6 versus 17.8, P = .23). Most patients (76%) did not have an awareness of BCS or BCS cost prior to bariatric surgery, and many (68%) had more loose skin than anticipated. CONCLUSIONS: Financial toxicity was similar across all postbariatric surgery patients surveyed regardless of history of BCS. However, survey respondents noted a gap between patient education and expectations around loose skin and body contouring that can be addressed through improved presurgical counseling.
Assuntos
Cirurgia Bariátrica , Contorno Corporal , Obesidade Mórbida , Centros de Atenção Terciária , Humanos , Feminino , Masculino , Contorno Corporal/economia , Cirurgia Bariátrica/economia , Cirurgia Bariátrica/efeitos adversos , Pessoa de Meia-Idade , Adulto , Obesidade Mórbida/cirurgia , Obesidade Mórbida/psicologia , Obesidade Mórbida/economia , Inquéritos e QuestionáriosRESUMO
Background: The risk and metabolic effects of obesity are determined by the distribution of fat throughout the body. It has been proposed that the distribution of abdominal fat is more closely related to the metabolic risks of obesity. High prevalence of overweight and obesity has thereby contributed to an increased uptake of surgical subcutaneous fat removal (SSFR) procedures. The goal of this study was to determine whether bioelectrical impedance analysis (Tanita system) can be used to detect the removal of excess abdominal subcutaneous fat tissue during SSFR when studying the metabolic effects of such procedures. Methods: Study population comprised patients who received body contouring procedures at the Hamad General Hospital's plastic surgery department between November 2020 and December 2022. To evaluate the factors of interest, subjects were prospectively followed up at two time points: within 1 week before the surgery and within 1-2 weeks thereafter. The following factors were measured: body weight, body fat percentage, body fat mass, body mass index (BMI), fat-free mass, estimated muscle mass, total body water, visceral fat score, and basal metabolic rate. Results: In total, 22 patients were included in the study. The two visits' medians for height, weight, BMI, fat percent (fat%), fat mass, visceral fat rating, and Doi's weighted average glucose (dwAG) were compared. Only in the case of Tanita fat% and fat mass, were the preoperative and postoperative medians significantly different. Furthermore, there was no association between these Tanita measures and dwAG or homeostatic model assessment (HOMA; insulin resistance [IR]) changes (before and after surgery). Tanita measures overestimated fat loss, as seen by the mountain plot and Bland-Altman plot agreement methods. Conclusions: Our findings indicated that the only two Tanita measures exhibited meaningful early associations with the amount of tissue excised which were fat mass and fat% differences. Although dwAG and HOMA-IR are not impacted immediately postsurgery, a trend was seen that suggested improvements in those parameters, even though the changes are not clinically significant.
Assuntos
Impedância Elétrica , Gordura Subcutânea , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Contorno Corporal/efeitos adversos , Estudos Prospectivos , Índice de Massa Corporal , Composição Corporal , Obesidade/cirurgia , Obesidade/diagnósticoRESUMO
BACKGROUND: The contour of the thigh is increasingly being recognized as crucial component of the ideal human physique, giving rise to heightened interest in attaining the perfect thigh profile. Notwithstanding, the contemporary landscape of cosmetic surgery appears to be bereft of efficient and precise objective methodologies to evaluate the outcomes of thigh contouring treatments. The present study is aimed to investigate the aesthetic appeal of varying thigh contours, employing specialized software as an indispensable instrument for quantitative and qualitative analysis. METHODS: Standardized photographs of the lower body were obtained from a sample of 200 healthy volunteers. A linear analysis was conducted, examining aspects such as the vertical length and transvers width of the thigh, as well as angular measurements including the posterior gluteal angle (PGA) and lateral angle thigh (LAT). Variables relating to thigh measurements and body mass index (BMI) were documented, with the relationships between them ascertained through Pearson's correlation and regression analysis. RESULTS: In males, the LAT was measured at 168 ± 3.9, and the PGA at 170 ± 3.4, while in females, these measurements were 166 ± 2.8 ve 166 ± 2.8, respectively. Linear analyses, including the vertical length of thigh (VLT), transverse width of thigh (TWT), lateral width (LW), and posterior width (PW), were conducted. Based on the LW inferior/LW superior ratio values, the most commonly observed thigh types were Type III (0.90) at 45% and Type II (0.85) at 24.75% while the least common was Type V at 4% (0.99). PW inferior/PW superior was 84.7%. The PWI/PWS ratio was highest for Type V, at 0.99, accounting for 84.70% of the total. Furthermore, an increase in the LWI/LWS ratio leads to an increase in the PWI/PWS ratio. The frequency of the VLT/TW1 ratio 0.31-0.35 (Type 3) was found to be on the left side and Type 4 on the right side. A strong correlation was found between BMI and all thigh indexes, with a significant positive correlation between the index and factors tied to the buttocks and upper thigh. CONCLUSIONS: The concept of an ideal thigh may vary based on an individual's gender, race, country of residence, and self-esteem, aiming to achieve a more natural silhouette. Focusing on the different ratios of hip and thigh varieties in the study is quite intriguing. Further inquiry and rigorous exploration are warranted to delineate the optimal techniques and methodologies for attaining ideal thigh proportions. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Estética , Coxa da Perna , Humanos , Coxa da Perna/anatomia & histologia , Feminino , Masculino , Adulto , Adulto Jovem , Fotografação , Índice de Massa Corporal , Voluntários Saudáveis , Pessoa de Meia-Idade , Contorno Corporal/métodosRESUMO
INTRODUCTION: Knowledge of the vascular anatomy is critical to performing safe gluteal surgery. To date, only the course of the main blood vessels within the muscles has been outlined. These findings are based on MRI and CTA images that do not conform to a topographically standardized and normalized probability distribution. OBJECTIVES: The aim of this study was to develop a three-dimensional mapping of the gluteal zones of high vascular density in relation to anatomical landmarks. MATERIALS AND METHODS: This single-center retrospective cohort analysis comprised all consecutive patients who underwent cone-beam computed tomography (CBCT) scans between January 2016 and October 2021. The location of blood vessels in the gluteal region was allometrically normalized in relation to anatomical landmarks. Moreover, the caliber and area of the blood vessels were assessed. RESULTS: CBCT scans of 32 patients with an average age of 64 ± 12 years (range 34-87 years) were included. Fifty-three percent were female. The median [IQR] caliber of the intramuscular gluteal vessels was 1.47 [1.15-1.88] mm, significantly greater than that of the subcutaneous vessels 1.09 [0.72-1.44] mm (p < 0.001). Vascular density was higher intramuscularly, as 4.5% of the area of the muscle was occupied by blood vessels, as opposed to 0.3% in the adipose tissue. CONCLUSION: The analysis of the CBCT scans showed a higher vascular density and larger vessels intramuscularly. We, therefore, recommend the injection of autologous fat merely to the subcutaneous plane. LEVEL OF EVIDENCE II: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Tecido Adiposo , Tomografia Computadorizada de Feixe Cônico , Humanos , Nádegas/irrigação sanguínea , Nádegas/cirurgia , Nádegas/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Masculino , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico/métodos , Tecido Adiposo/transplante , Idoso de 80 Anos ou mais , Estudos de Coortes , Imageamento Tridimensional , Transplante Autólogo/métodos , Medição de Risco , Segurança do Paciente , Contorno Corporal/métodos , Contorno Corporal/efeitos adversosRESUMO
BACKGROUND: Liposuction is considered one of the most common procedures in plastic surgery. However, major postoperative complications such as visceral injury, fluid overload, and necrotizing fasciitis still occur. Likewise, minor complications such as ecchymosis, seromas, infections, and contour irregularities that do not threaten the life of the patient do generate significant dissatisfaction. Current evidence regarding the management of fibrosis after previous liposuction remains limited. OBJECTIVES: The objective of this article is to standardize a management algorithm based on the extensive experience and successful results of the primary author (G.M.). METHODS: Patients who underwent secondary liposculpture between August 2022 and May 2023 were evaluated prospectively. Inclusion criteria comprised females between 18 and 60 years old, nonsmokers, with a BMI < 35â kg/m2 and a history of previous body contouring surgeries. Identification of the patient's skin condition and subcutaneous lesions in the adipose tissue were obtained in detail. Statistical analysis of preoperative and postoperative medical photographs was also performed with the Fiji Biological image analyzer. RESULTS: Photographic analysis of preoperative and postoperative photographs showed a statistically significant difference between the areas affected by fibrosis (P < .001). The most frequent clinical findings were depressions in 99% of the females (74), followed by soft nodules in 95% (70), hard nodules in 81% (61), adhesions in 47% (35), and finally cutaneous bursas in 4%. CONCLUSIONS: Our classification system and management algorithm for fibrosis and contour irregularities is a safe and reliable tool. Results were objectively verified, yielding statistically significant outcomes.
Assuntos
Algoritmos , Fibrose , Lipectomia , Complicações Pós-Operatórias , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Lipectomia/métodos , Lipectomia/efeitos adversos , Adulto Jovem , Estudos Prospectivos , Adolescente , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico , Contorno Corporal/métodos , Contorno Corporal/efeitos adversos , Fotografação , Resultado do TratamentoRESUMO
Massive weight loss following bariatric surgery is often accompanied by functional impairments due to the resulting excess skin and soft tissues. To achieve both functional reconstruction and restoration of the body silhouette, it is imperative to undergo body contouring surgery involving the strategic transposition of tissues. Several surgical techniques are available for the affected body regions and their application for treatment is determined by the unique circumstances specific to each patient. When conducted by skilled practitioners, postbariatric body reconstruction can be executed safely, leading to outcomes that are both functionally and esthetically satisfying, ultimately contributing to an enhanced quality of life for patients. This article provides the fundamental principles for patient selection, surgical preparation, treatment planning, surgical techniques and the postoperative care following bariatric surgery.
Assuntos
Cirurgia Bariátrica , Contorno Corporal , Procedimentos de Cirurgia Plástica , Cirurgia Plástica , Humanos , Qualidade de Vida , Contorno Corporal/métodos , Cirurgia Bariátrica/efeitos adversosRESUMO
OBJECTIVE: To examine health-related quality of life (HRQL) and satisfaction with appearance in patients who have undergone bariatric surgery (BS) with or without subsequent body contouring surgery (BCS) in relation to the general population normative for the BODY-Q. BACKGROUND: The long-term impact of BS with or without BCS has not been established using rigorously developed and validated patient-reported outcome measures. The BODY-Q is a patient-reported outcome measure developed to measure changes in HRQL and satisfaction with appearance in patients with BS and BCS. METHODS: Prospective BODY-Q data were collected from 6 European countries (Denmark, the Netherlands, Finland, Germany, Italy, and Poland) from June 2015 to February 2022 in a cohort of patients who underwent BS. Mixed-effects regression models were used to analyze changes in HRQL and appearance over time between patients who did and did not receive BCS and to examine the impact of patient-level covariates on outcomes. RESULTS: This study included 24,604 assessments from 5620 patients. BS initially led to improved HRQL and appearance scores throughout the first postbariatric year, followed by a gradual decrease. Patients who underwent subsequent BCS after BS experienced a sustained improvement in HRQL and appearance or remained relatively stable for up to 10 years postoperatively. CONCLUSIONS: Patients who underwent BCS maintained an improvement in HRQL and satisfaction with appearance in contrast to patients who only underwent BS, who reported a decline in scores 1 to 2 years postoperatively. Our results emphasize the pivotal role that BCS plays in the completion of the weight loss trajectory.
Assuntos
Cirurgia Bariátrica , Contorno Corporal , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Qualidade de Vida , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Longitudinais , Europa (Continente) , Obesidade Mórbida/cirurgia , Obesidade Mórbida/psicologiaRESUMO
BACKGROUND: Body contouring surgery after massive weight loss has emerged a safe and reliable option to improve self-esteem, social life, work ability, physical activity, and sexual activity, and it is considered as an essential step in the multidisciplinary approach to morbid obesity. In this study, we aim to provide a comprehensive overview of the current state of literature on body contouring after massive weight loss, identifying research trends and areas for future investigation. METHODS: The Web of Science Core Collection was used to identify the 50 most cited publications on post-massive weight loss surgery. Data collected from each article included: title, journal, publication year, total citations, average citations per year, authors, study type, study topic, country, and institution of origin. RESULTS: The top 50 most-cited articles include 44 original articles and 6 review articles. The most cited article, published by Lockwood in 1991, received a total of 224 citations. The research areas included surgical outcomes and complications (n=19, 38%), psychological aspects such as body image, quality of life and desire for body contouring procedures (n=18, 36%), surgical techniques (n=11, 22%), an anatomical study (n=1, 2%), and a classification system (n=1; 2%). Plastic and Reconstructive Surgery journal published most (44%) of the papers identified. The University of Pittsburgh was the single institution that contributed the most (n=11; 22%). CONCLUSION: This bibliometric analysis provides insights and research trends for clinicians interested in body contouring after massive weight loss, facilitating the understanding and evolution of post-bariatric surgery and elucidating the rationale behind current practice. NO LEVEL ASSIGNED: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Bibliometria , Contorno Corporal , Redução de Peso , Humanos , Contorno Corporal/métodos , Obesidade Mórbida/cirurgia , Feminino , Masculino , Cirurgia Bariátrica/métodos , Qualidade de VidaRESUMO
INTRODUCTION: Large language models (LLM) have revolutionized the way humans interact with artificial intelligence (AI) technology, with marked potential for applications in esthetic surgery. The present study evaluates the performance of Bard, a novel LLM, in identifying and managing postoperative patient concerns for complications following body contouring surgery. METHODS: The American Society of Plastic Surgeons' website was queried to identify and simulate all potential postoperative complications following body contouring across different acuities and severity. Bard's accuracy was assessed in providing a differential diagnosis, soliciting a history, suggesting a most-likely diagnosis, appropriate disposition, treatments/interventions to begin from home, and red-flag signs/symptoms indicating deterioration, or requiring urgent emergency department (ED) presentation. RESULTS: Twenty-two simulated body contouring complications were examined. Overall, Bard demonstrated a 59% accuracy in listing relevant diagnoses on its differentials, with a 52% incidence of incorrect or misleading diagnoses. Following history-taking, Bard demonstrated an overall accuracy of 44% in identifying the most-likely diagnosis, and a 55% accuracy in suggesting the indicated medical dispositions. Helpful treatments/interventions to begin from home were suggested with a 40% accuracy, whereas red-flag signs/symptoms, indicating deterioration, were shared with a 48% accuracy. A detailed analysis of performance, stratified according to latency of postoperative presentation (<48hours, 48hours-1month, or >1month postoperatively), and according to acuity and indicated medical disposition, is presented herein. CONCLUSIONS: Despite promising potential of LLMs and AI in healthcare-related applications, Bard's performance in the present study significantly falls short of accepted clinical standards, thus indicating a need for further research and development prior to adoption. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .