Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.000
Filtrar
1.
BMC Ophthalmol ; 24(1): 388, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39227793

RESUMO

BACKGROUND: Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. METHODS: This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. RESULTS: Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (ß = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (ß = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (ß = -16.653, P < 0.001). CONCLUSIONS: The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.


Assuntos
Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Adulto , Masculino , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Seguimentos , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Córnea/cirurgia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Período Pós-Operatório
2.
J Refract Surg ; 40(9): e604-e613, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39254241

RESUMO

PURPOSE: To compare the clinical and aberrometric outcomes obtained with a new diffractive pentafocal intraocular lens (IOL) and a diffractive trifocal IOL. METHODS: Patients bilaterally implanted with the pentafocal Intensity SeeLens IOL (Hanita Lenses) (n = 30) and the trifocal FineVision POD F IOL (PhysIOL) (n = 30) during cataract surgery were studied after 1 month for refraction, visual acuity, defocus curve, contrast sensitivity, Hartmann-Shack aberration, and double-pass aberration. The Quality of Vision (QoV) questionnaire was used to evaluate visual comfort. RESULTS: Distance and near visual acuities were similar with the two IOLs, but distance-corrected intermediate visual acuity was better with the Intensity IOLs (0.03 ± 0.04 vs 0.11 ± 0.04 logMAR in the FineVision eyes, P < .01). The difference between objective and subjective refraction was more myopic for the Intensity IOL (-1.15 vs -0.29 diopters [D]). The defocus curve was flatter with the Intensity IOL. Contrast sensitivity was similar in both IOLs. Hartmann-Shack aberration and double-pass aberration were similar, but the modulation transfer function cut-off value was worse with the Intensity IOL: 11.6 ± 2.7 vs 15.3 ± 4.9 (P < .01). QoV scores were better with the Intensity IOL, in particular for glare, halos, and starburst. CONCLUSIONS: In this comparative series, the pentafocal Intensity IOL provided better intermediate vision and better defocus curve than the FineVision IOL, with comparable distance and near vision. The optical disturbances as reported by the patients were higher with the FineVision IOL. Additional studies will better define the aberration profile obtained with the pentafocal IOL. [J Refract Surg. 2024;40(9):e604-e613.].


Assuntos
Sensibilidades de Contraste , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Facoemulsificação , Desenho de Prótese , Pseudofacia , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Sensibilidades de Contraste/fisiologia , Feminino , Masculino , Pseudofacia/fisiopatologia , Idoso , Pessoa de Meia-Idade , Inquéritos e Questionários , Estudos Prospectivos , Satisfação do Paciente , Aberrometria , Lentes Intraoculares , Aberrações de Frente de Onda da Córnea/fisiopatologia
3.
J Refract Surg ; 40(9): e645-e653, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39254243

RESUMO

PURPOSE: To evaluate the intrasession repeatability of wavefront aberrations obtained by a combined adaptive optics visual simulator and Hartman-Shack aberrometer in pseudophakic eyes with and without previous corneal refractive surgery. METHODS: Three consecutive measurements were performed in one eye of each individual. Total ocular aberrations were recorded up to the 5th Zernike order for a 4.5-mm pupil. Repeatability was assessed by calculating the within-subject standard deviation (Sw), the repeatability limit (R), and the intraclass correlation coefficient (ICC). Vector analysis was performed to assess astigmatism variability between scans. RESULTS: The study enrolled 32 normal individuals and 24 individuals with a history of refractive surgery. In normal and eyes that had previous refractive surgery, respectively, the Sw values were 0.155 and 0.176 diopters (D) for sphere and 0.184 and 0.265 D for cylinder. The Sw values for all 3rd order terms ranged from 0.037 to 0.047 µm in normal eyes and 0.044 to 0.063 µm in eyes that had previous refractive surgery. The Sw for primary spherical aberration was 0.020 µm in normal eyes and 0.026 µm in eyes that had previous refractive surgery. ICC values for measurements of astigmatism yielded larger variability (ICC = 0.751 and 0.879). However, both groups demonstrated excellent repeatability (ICC > 0.9) for root mean square higher order aberrations (RMS-HOA) and total RMS values. CONCLUSIONS: In pseudophakic eyes, the adaptive optics Hartmann-Shack device demonstrated acceptable repeatability for measurement of sphere and 3rd and 4th order HOAs with higher variability for astigmatism measurements, especially in eyes with a prior history of corneal refractive surgery. [J Refract Surg. 2024;40(9):e645-e653.].


Assuntos
Aberrometria , Aberrações de Frente de Onda da Córnea , Pseudofacia , Refração Ocular , Acuidade Visual , Humanos , Pseudofacia/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Reprodutibilidade dos Testes , Feminino , Pessoa de Meia-Idade , Masculino , Adulto , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Idoso , Topografia da Córnea , Procedimentos Cirúrgicos Refrativos , Óptica e Fotônica , Estudos Prospectivos , Córnea/fisiopatologia
6.
PeerJ ; 12: e17940, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39184392

RESUMO

Purpose: To compare the visual quality after wavefront-guided femtosecond LASIK (WFG FS-LASIK) in patients with different levels of preoperative total ocular higher-order aberrations to guide clinical decision-making regarding patient selection and treatment strategies. Methods: This study included 112 right eyes of 112 patients who previously underwent WFG FS-LASIK for correcting myopia and myopic astigmatism. The patients were divided into two groups based on the mean values of preoperative total ocular HOAs (0.30 ± 0.09 µm): HOA ≤ 0.3 and > 0.3 groups. The visual acuity, manifest refraction, corneal Strehl ratio (SR), root mean square (RMS) of corneal and ocular aberrations, and area under the log contrast sensitivity function (AULCSF) of both groups were compared preoperatively and at 1, 3, 6, and 12 months postoperatively. Results: The induced ocular HOAs and coma (Δ = 1 mo - Preop) were significantly lower in the HOAs > 0.3 group than in the HOAs ≤ 0.3 group (ΔHOAs: 0.39 ± 0.19 vs. 0.29 ± 0.18 µm, t = 2.797, P = 0.006; Δ coma: 0.30 ± 0.19 vs. 0.20 ± 0.21 µm, t = 2.542, P = 0.012). In the HOAs > 0.3 group, ΔHOAs were negatively correlated with the preoperative ocular HOAs (r = -0.315, P = 0.019). In the HOAs ≤ 0.3 group, the regression equation for Δ HOAs = 0.098 + 0.053 |SE| (F = 21.756, P < 0.001). In the HOAs > 0.3 group, the regression equation for ΔHOAs = 0.534 - 1.081 HOAs + 0.038|Sphere| (F = 7.954, P = 0.001). The postoperative uncorrected distance visual acuity, spherical equivalent, corneal aberrations, SR and AULCSF of both groups were similar (all P > 0.05). Furthermore, the ocular aberrations were not significantly different between both groups at 3, 6, and 12 months postoperatively (all P > 0.05). In addition, compared with the preoperative period, the AULCSF of both groups were significantly increased in the postoperative period (all P < 0.05). Conclusions: The induced ocular HOAs and coma in HOAs > 0.3 group were lower. However, both groups achieved equivalent and excellent visual quality after WFG FS-LASIK. WFG FS-LASIK may provide significant visual benefits for a wider range of patients.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Masculino , Acuidade Visual/fisiologia , Adulto , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Resultado do Tratamento , Pessoa de Meia-Idade , Sensibilidades de Contraste/fisiologia
7.
BMC Ophthalmol ; 24(1): 328, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107739

RESUMO

BACKGROUND: Visual impairment can cause balance problems. Therefore, visual impairment caused by an increase in corneal deviations can lead to sudden and unstable loads in the lower extremities. We aimed to investigate the possible relationship between low-energy meniscal injuries and corneal structural measures. METHODS: This prospective, observational study included individuals aged between 18-40 years with a normal body-mass index. The study group consisted of 54 patients with grade 2 or 3 meniscus injuries after low-energy activity. The control group consisted of 54 healthy individuals without any complaints in the knee joint. The corneal parameters of all participants were evaluated with a Scheimpflug corneal topography and specular microscopy device. Simulated keratometry (SimK), minimum central corneal thickness (MCCT), cylindrical diopter (ClyD), corneal volume (CVol) spheric aberrations (SphAbb), high-order aberration (HOA), coma values, and endothelial parameters were recorded. RESULTS: The research and control groups were similar in terms of age, body mass index, and gender distribution. There was no significant difference between the groups in the corneal SimK and CylD, parameters. However, HOA, Coma, SphAbb, and cell variability (Cv) values were significantly higher in the study group, and contrarily MCCT, CVol, and endothelial count (Cd) values were significantly lower. CONCLUSIONS: Our findings suggest that individuals with relatively lower MCCT values tend to develop meniscal damage after low-energy activity. Hence, the loss of corneal strength in these patients may be a sign of possible weakness in the meniscus. The HOA value above 0.26, the coma value above 0.16, and the SphAbb value above 0.1 may significantly increase the possible meniscus injury.


Assuntos
Topografia da Córnea , Humanos , Masculino , Feminino , Estudos Prospectivos , Adulto , Adulto Jovem , Adolescente , Lesões do Menisco Tibial/fisiopatologia , Córnea/patologia , Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Acuidade Visual/fisiologia
8.
J Refract Surg ; 40(7): e490-e498, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007811

RESUMO

PURPOSE: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions). METHODS: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals. RESULTS: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group (P < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group (P < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group (P < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively (P < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all P < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all P < .001). CONCLUSIONS: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. [J Refract Surg. 2024;40(7):e490-e498.].


Assuntos
Substância Própria , Lasers de Excimer , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Feminino , Masculino , Ceratectomia Fotorrefrativa/métodos , Adulto , Refração Ocular/fisiologia , Adulto Jovem , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea , Seguimentos , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Estudos Retrospectivos
9.
Int Ophthalmol ; 44(1): 331, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037500

RESUMO

PURPOSE: To compare the clinical outcomes of myopiacorrected with corneal-wavefront-guided (CWG) laser in situ keratomileusis (LASIK) with AMARIS 1050S (SCHWIND eye-tech-solutions GmbH & Co. KG) and corneal-topography-guided (CTG) LASIK with WaveLight EX500 (Alcon Laboratories, Fort Worth, TX). METHODS: In this prospective, pseudo-randomized expanded cohort study, a total of 266 patients were subjected to binocular LASIK surgery, either with WaveLight EX500 (WaveLight group) or Amaris 1050S (AMARIS group) platforms. Data related to right eyes were selected for analysis. Corneal higher-order aberration (HOA) was selected as the primary endpoint; while visual acuity and refraction were the secondary endpoints. All the endpoints were assessed at 3 months postoperatively. RESULTS: There were 134 eyes in the AMARIS group and 132 eyes in the WaveLight group. After 3 months of postoperative follow-up, spherical and coma aberrations were significantly lower (P < 0.05) in the WaveLight group (spherical aberration: - 0.104 ± 0.199 µm; coma aberration: - 0.117 ± 0.202 µm) in comparison with the AMARIS group (spherical aberrations: 0.254 ± 0.146 µm; coma aberrations: 0.316 ± 0.297 µm). In the AMARIS group, 96.3% of the eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 while in the WaveLight group, 96.2% of the eyes achieved an UDVA of 20/20. Furthermore, the mean postoperative manifest refraction spherical equivalent (MRSE) was - 0.02 ± 0.28 in the AMARIS group and - 0.05 ± 0.21 in the WaveLight group (P = 0.34). CONCLUSIONS: Both WaveLight EX500 and Amaris 1050S LASIK showed excellent refractive and visual outcomes. In addition, the WaveLight group showed minimal spherical and coma aberrations when compared to the AMARIS group.


Assuntos
Córnea , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Estudos Prospectivos , Masculino , Adulto , Refração Ocular/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Adulto Jovem , Resultado do Tratamento , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Seguimentos
10.
J Refract Surg ; 40(7): e499-e505, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007813

RESUMO

PURPOSE: To assess the effects of intraocular lens (IOL) decentration and tilt, as well as age, on postoperative visual function (corrected distance visual acuity [CDVA] and contrast sensitivity) by comparing an extended depth-of-focus IOL using higher order aspheric optics against a monofocal IOL from the same platform. METHODS: This retrospective observational study targeted patients without other eye diseases who underwent surgery to implant the Tecnis Eyhance OptiBlue or the monofocal IOL Tecnis OptiBlue 1-Piece (J&J Vision) during cataract surgery from November 2021 to December 2022. The effects of age, axial length, IOL decentration, tilt, and corneal higher order aberrations (HOAs) on the postoperative 5 m CDVA and area under log contrast sensitivity function (AULCSF) under photopic and scotopic conditions were evaluated within 3 months of surgery. RESULTS: No significant difference was found in postoperative CDVA between the Tecnis Eyhance OptiBlue group (n = 61 eyes) and the Tecnis OptiBlue 1-Piece group (n = 35 eyes), but AULCSF was significantly better in the Tecnis Eyhance OptiBlue group for photopic (1.58 ± 0.13 vs 1.46 ± 0.18; P = .002) and scotopic (1.71 ± 0.11 vs 1.59 ± 0.19; P = .002) eyes. Multivariate analysis showed a negative correlation between AULCSF and IOL decentration and age in the Tecnis Eyhance OptiBlue group (P < .01), with no significant correlation with tilt, axial length, and corneal HOAs. CONCLUSIONS: The Tecnis Eyhance OptiBlue yielded significantly better contrast sensitivity under photopic and scotopic conditions than the Tecnis OptiBlue 1-Piece. However, it is important to consider the effects of IOL decentration and age when evaluating the contrast sensitivity of the Tecnis Eyhance OptiBlue. [J Refract Surg. 2024;40(7):e499-e505.].


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Percepção de Profundidade/fisiologia , Refração Ocular/fisiologia , Migração do Implante de Lente Intraocular/fisiopatologia , Idoso de 80 Anos ou mais , Período Pós-Operatório , Comprimento Axial do Olho , Aberrações de Frente de Onda da Córnea/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA