Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 494
Filtrar
1.
BMC Anesthesiol ; 24(1): 174, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745175

RESUMO

BACKGROUND: Compared to midazolam, remimazolam has a faster onset and offset of hypnotic effect, as well as cardiorespiratory stability, this study aims to determine the 90% effective dose (ED90) of remimazolam to inhibit responses to insertion of a duodenoscope during endoscopic retrograde cholangiopancreatography (ERCP). METHODS: A dose-response study was carried out undergoing ERCP who received remimazolam-alfentanil anesthesia using 10 µg/kg of alfentanil between September 2021 and November 2021. The initial dose of remimazolam was 0.2 mg/kg. The dose was then decided based on the responses of earlier patients by exploiting the sequential ascend and descend according to a 9: 1 biased coin design. Upon failure, the dose of remimazolam was increased by 0.025 mg/kg in the next patient. When the insertion was successful, the succeeding patient was randomized to an identical dose or a dose that was lower by 0.025 mg/kg.The ED90 of remimazolam for inhibiting responses to the insertion of a duodenoscope during ERCP was calculated. Adverse events and complications of remimazolam were recorded. RESULTS: A total of 55 elderly patients (age > 65) were included in the study. 45 successfully anesthetized patients, and 10 unsuccessfully. The ED90 of remimazolam was 0.300 mg/kg (95% CI = 0.287-0.320). ED95 was 0.315 (95% CI = 0.312-0.323) and ED99 was 0.323 (95% CI = 0.323-0.325). Among the patients, 9 patients developed hypotension, 2 patients developed bradycardia and 1 patient developed tachycardia, and hypoxia occurred in 2 patients. CONCLUSIONS: A loading dose of 0.300 mg / kg of remimazolam for elderly patients undergoing ERCP can safely, effectively, and quickly induce patients to fall asleep and inhibit responses to the insertion of a duodenoscope. TRIAL REGISTRATION: The study protocol was registered at the website ClinicalTrials.gov on 22/09/2021(NCT05053763).


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Relação Dose-Resposta a Droga , Duodenoscópios , Hipnóticos e Sedativos , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Masculino , Feminino , Hipnóticos e Sedativos/administração & dosagem , Idoso , Alfentanil/administração & dosagem , Pessoa de Meia-Idade , Benzodiazepinas/administração & dosagem
2.
Surg Laparosc Endosc Percutan Tech ; 34(3): 321-329, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38767593

RESUMO

OBJECTIVE: Endoscopes are an essential tool in the diagnosis, screening, and treatment of gastrointestinal diseases. In 2019, the Food and Drug Administration issued a news release, recommending that duodenoscope manufacturers and health care facilities phase out fully reusable duodenoscopes with fixed endcaps in lieu of duodenoscopes that are either fully disposable or those that contain disposable endcaps. With this study, we systematically reviewed the published literature on single-use disposable gastrointestinal scopes to describe the current state of the literature and provide summary recommendations on the role of disposable gastrointestinal endoscopes. MATERIALS AND METHODS: For our inclusion criteria, we searched for studies that were published in the year 2015 and afterward. We performed a literature search in PubMed using the keywords, "disposable," "reusable," "choledochoscope," "colonoscope," "duodenoscope," "esophagoscope," "gastroscope," and "sigmoidoscope." After our review, we identified our final article set, including 13 articles relating to disposable scopes, published from 2015 to 2023. RESULTS: In this review, we show 13 articles discussing the infection rate, functionality, safety, and affordability of disposable gastrointestinal scopes in comparison to reusable gastrointestinal scopes. Of the 3 articles that discussed infection rates (by Forbes and colleagues, Ridtitid and colleagues, and Ofosu and colleagues), each demonstrated a decreased risk of infection in disposable gastrointestinal scopes. Functionality was another common theme among these articles. Six articles (by Muthusamy and colleagues, Bang and colleagues, Lisotti and colleagues, Ross and colleagues, Kang and colleagues, and Forbes and colleagues) demonstrated comparable functionality of disposable scopes to reusable scopes. The most reported functionality issue in disposable scopes was decreased camera resolution. Disposable scopes also showed comparable safety profiles compared with reusable scopes. Six articles (by Kalipershad and colleagues, Muthusamy and colleagues, Bang and colleagues, Lisotti and colleagues, Luo and colleagues, and Huynh and colleagues) showed comparable rates of AEs, whereas 1 article (by Ofosu and colleagues) demonstrated increased rates of AEs with disposable scopes. Lastly, a cost analysis was looked at in 3 of the articles. Two articles (by Larsen et al and Ross and colleagues) remarked that further research is needed to understand the cost of disposable scopes, whereas 1 article (by Kang and colleagues) showed a favorable cost analysis. CONCLUSIONS: After a review of the literature published since the 2015 Food and Drug Administration safety communication, disposable scopes have been shown to be effective in decreasing infection risks while maintaining similar safety profiles to conventional reusable scopes. However, more research is required to compare disposable and reusable scopes in terms of functionality and cost-effectiveness.


Assuntos
Equipamentos Descartáveis , Reutilização de Equipamento , Equipamentos Descartáveis/economia , Humanos , Reutilização de Equipamento/economia , Endoscópios Gastrointestinais , Desenho de Equipamento , Gastroenteropatias/diagnóstico , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/economia , Duodenoscópios/microbiologia
3.
Surg Endosc ; 38(6): 3361-3367, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38710887

RESUMO

INTRODUCTION: Disposable duodenoscopes and duodenoscopes with disposable endcaps are being used in clinical practice to reduce or eliminate the risk of transmitting infections. The study aim was to assess perceptions and experiences regarding the use of these duodenoscopes among advanced endoscopy fellows in a nationally representative sample. METHODS: A 17-item electronic survey was sent to 74 advanced endoscopy training programs. The survey was completed by 50 participants and their responses were included for analysis. RESULTS: Most participants were from academic training programs (82.7%) and identified as being in their 7th year of post graduate training (92%; PGY-7). Participants performed an average of 414 ERCPs. 29% reported difficulty with cannulation using disposable duodenoscopes versus 15.7% with duodenoscopes with disposable endcaps (vs. standard duodenoscope). 96% of trainees perceived disposable duodenoscopes as not cost effective and 92% stated they would not use this device during independent practice. 100% of trainees stated that they would use duodenoscopes with disposable endcaps during independent practice. For their most challenging cases, 90% of trainees preferred using standard reprocessable duodenoscopes while no trainee indicated they would prefer using a disposable duodenoscope in this scenario. 82% of participants stated that disposable duodenoscopes and disposable endcaps should be used exclusively or preferentially for high-risk patients citing cost, functionality, and concerns regarding environmental impact. DISCUSSION: Advanced endoscopy fellows perceive disposable duodenoscopes as impacting technical maneuverability. Concerns about functionality, cost effectiveness and environmental impact are barriers to adoption.


Assuntos
Equipamentos Descartáveis , Duodenoscópios , Equipamentos Descartáveis/economia , Humanos , Atitude do Pessoal de Saúde , Inquéritos e Questionários , Colangiopancreatografia Retrógrada Endoscópica , Internato e Residência , Estados Unidos
4.
J Hosp Infect ; 149: 36-45, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38649121

RESUMO

BACKGROUND: Contamination rates reported in the literature for patient-ready flexible endoscopes vary from 0.4% to 49%. Unfortunately, the comparison and interpretation of these results is almost impossible since several factors including sampling and culturing methods, target levels for contamination, or definition of indicator micro-organisms vary widely from one study to the other. AIM: To compare the efficacy of six duodenoscope sampling and culturing methods by means of extraction efficacy comparison, while at the same time identifying key parameters that provide optimal microbial recovery. METHODS: The duodenoscope sample extraction efficacy of each method was assessed using the repetitive recovery method described in ISO 11737-1: 2018. FINDINGS: Mean overall bioburden extraction efficacy varied from 1% for the Australian method to 39% for the French one. The lowest endoscope sample extraction efficacy was associated with the absence of any neutralizer, friction, or tensioactive agent, and when only a small portion of the sampling solution collected was inoculated on to culture media. The efficacy of the sampling and culturing methods also varied according to the nature of micro-organisms present in the endoscope, and the time between sampling and culturing. CONCLUSION: This study supports the need for a harmonized and standardized sampling and culturing method for flexible endoscopes.


Assuntos
Contaminação de Equipamentos , Manejo de Espécimes , Humanos , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação , Contaminação de Equipamentos/prevenção & controle , Bactérias/isolamento & purificação , Bactérias/classificação , Técnicas Microbiológicas/métodos , Endoscópios/microbiologia , Duodenoscópios/microbiologia
5.
BMC Pediatr ; 24(1): 281, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678261

RESUMO

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) has found extensive use in pediatric patients; however, challenges persist in the application of therapeutic ERCP in infants. CASE PRESENTATION: This case report details the presentation of a 5.9-kilogram infant with obstructive jaundice and suspected hemolytic anemia who underwent ERCP to alleviate biliary obstruction. The infant was admitted due to clay-colored stools, jaundice, and liver injury. Ultrasound and magnetic resonance cholangiopancreatography (MRCP) revealed dilation of the common bile duct (CBD) accompanied by the presence of stones. ERCP was conducted using a JF-260V duodenoscope under general anesthesia. Successful stone extraction and biliary drainage were achieved. CONCLUSIONS: In centers with considerable expertise in ERCP and pediatric anesthesia, the use of a conventional adult duodenoscope for therapeutic ERCP in infants can be considered safe and feasible, provided careful and stringent patient selection criteria are applied. In the future, clear guidelines and standardized protocols for the indications and procedures of pediatric ERCP should be established.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Icterícia Obstrutiva , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Icterícia Obstrutiva/etiologia , Icterícia Obstrutiva/terapia , Icterícia Obstrutiva/diagnóstico por imagem , Lactente , Masculino , Colestase/etiologia , Colestase/diagnóstico por imagem , Colestase/terapia
6.
Dig Dis Sci ; 69(6): 1956-1962, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38466461

RESUMO

BACKGROUND AND AIMS: In response to documented duodenoscope-related infectious outbreaks of multidrug-resistant organisms, the Food and Drug Administration has recommended a transition to duodenoscopes with innovative designs, including duodenoscopes with disposable components or fully disposable duodenoscopes. We aim to characterize the learning curve (LC) for a single-use disposable duodenoscope. METHODS: We performed a retrospective analysis of a prospectively collected database from 31 patients who underwent ERCP by a single, experienced operator using the EXALT Model D® (Boston Scientific, Marlborough) disposable duodenoscope at a single tertiary referral center. The LC for this device was described by the number of cases needed to achieve proficiency using cumulative sum (CUSUM) analysis. Number of attempts to cannulate and time to cannulate the desired duct were assessed as separate endpoints. The overall mean number of attempts and overall mean time to cannulation were used as the target values in the respective CUSUM analyses. Proficiency was defined as the number of procedures where an inflection point was reached in the CUSUM graph. This observation indicates improving operator performance as shown by a decrease in the number of attempts and shortening of cannulation time after the defined number of procedures. RESULTS: Overall, 31 patients underwent ERCP using the EXALT Model D disposable duodenoscope by a single experienced endoscopist. 6 (19%) patients had a native papilla and the majority of these procedures were classified as ASGE complexity level 2 or above. The procedure was completed using solely the disposable duodenoscope in 27 patients (87%), while a reusable duodenoscope was required for procedure completion in 4 patients (13%). The cross-overs were distributed evenly across the performance period. Procedure-related adverse events included: post-ERCP pancreatitis (3%), bleeding (3%) and no perforations. In the analyses of both endpoints, an inflection of the CUSUM curves is achieved at 10 cases, indicating sustained reduction of cannulation attempts and time to cannulation. CONCLUSION: Among experienced pancreaticobiliary endoscopists, approximately 10 ERCPs is the threshold whereby procedure-related factors including cannulation success and procedural time improves. Procedure-related adverse events are consistent with those expected with reusable duodenoscopes. The need to cross-over from single-use duodenoscope to reusable duodenoscope did not appear to be related to the learning curve, as they were evenly distributed across the study period. These results can be used to guide adoption of single-use duodenoscopes into clinical practice.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Equipamentos Descartáveis , Duodenoscópios , Curva de Aprendizado , Humanos , Duodenoscópios/microbiologia , Estudos Retrospectivos , Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Colangiopancreatografia Retrógrada Endoscópica/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Competência Clínica , Desenho de Equipamento
9.
Gastrointest Endosc ; 100(2): 312-316, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38462055

RESUMO

BACKGROUND AND AIMS: Duodenoscopes with single-use end caps were introduced to minimize infection risk, but they are unstudied in pediatrics. METHODS: We collected clinical data and endoscopists' evaluations of duodenoscopes with single-use end caps versus reusable duodenoscopes over 18 months. RESULTS: A total of 106 ERCPs were performed for patients aged 1 to 18 (mean, 14.2) years. Forty-six involved single-use end caps, with 9 requiring crossover to reusable duodenoscopes. ERCPs involving single-use end caps resulted in more instances of mucosal trauma (10 vs 0; P < .05) and post-ERCP pancreatitis (4 vs 1; P < .05) and accounted for 8 of 9 ERCPs requiring advanced cannulation techniques. No post-ERCP infections occurred. Reported challenges included single-use end cap stiffness and difficulty with their alignment for cannulation. CONCLUSIONS: We report difficulty with advancement, greater reliance on advanced cannulation techniques, and higher rates of post-ERCP pancreatitis when using duodenoscopes with single-use end caps in pediatric ERCP. This area warrants further study.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Duodenoscópios/microbiologia , Criança , Adolescente , Pré-Escolar , Lactente , Feminino , Masculino , Pancreatite/prevenção & controle , Pancreatite/etiologia , Reutilização de Equipamento/economia , Desenho de Equipamento , Equipamentos Descartáveis/economia , Estudos Retrospectivos , Cateterismo
10.
J Hosp Infect ; 147: 56-62, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447805

RESUMO

BACKGROUND: Duodenoscope-associated infections (DAIs) are exogenous infections resulting from the use of contaminated duodenoscopes. Though numerous outbreaks of DAI have involved multidrug-resistant micro-organisms (MDROs), outbreaks involving non-MDROs are also likely to occur. Detection challenges arise as these infections often resolve before culture or because causative strains are not retained for comparison with duodenoscope strains. AIM: To identify and analyse DAIs spanning a seven-year period in a tertiary care medical centre. METHODS: This was a retrospective observational study. Duodenoscope cultures positive for gastrointestinal flora between March 2015 and September 2022 were paired with duodenoscope usage data to identify patients exposed to contaminated duodenoscopes. Analysis encompassed patients treated after a positive duodenoscope culture and those treated within the interval from a negative to a positive culture. Patient identification numbers were cross-referenced with a clinical culture database to identify patients developing infections with matching micro-organisms within one year of their procedure. A 'pair' was established upon a species-level match between duodenoscope and patient cultures. Pairs were further analysed via antibiogram comparison, and by whole-genome sequencing (WGS) to determine genetic relatedness. FINDINGS: Sixty-eight pairs were identified; of these, 21 exhibited matching antibiograms which underwent WGS, uncovering two genetically closely related pairs categorized as DAIs. Infection onset occurred up to two months post procedure. Both causative agents were non-MDROs. CONCLUSION: This study provides crucial insights into DAIs caused by non-MDROs and it highlights the challenge of DAI recognition in daily practice. Importantly, the delayed manifestation of the described DAIs suggests a current underestimation of DAI risk.


Assuntos
Duodenoscópios , Humanos , Estudos Retrospectivos , Duodenoscópios/microbiologia , Duodenoscópios/efeitos adversos , Centros de Atenção Terciária , Testes de Sensibilidade Microbiana , Masculino , Feminino , Bactérias/isolamento & purificação , Bactérias/classificação , Bactérias/genética , Contaminação de Equipamentos
11.
Pancreas ; 53(4): e357-e367, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38518062

RESUMO

OBJECTIVES: Secondary infections due to transmission via the duodenoscope have been reported in up to 3% of endoscopic retrograde cholangiopancreatographies. The use of single-use duodenoscopes has been suggested. We investigate the cost-effectiveness of these duodenoscopes use in cholangiopancreatography. MATERIALS AND METHODS: A cost-effectiveness analysis was implemented to compare the performance of cholangiopancreatographies with reusable duodenoscopes versus single-use duodenoscopes. Effectiveness was analyzed by calculating quality-adjusted life years (QALY) from the perspective of the National Health System. Possibility of crossover from single-use to reusable duodenoscopes was considered. A willingness-to-pay of €25,000/QALY was set, the incremental cost-effectiveness ratio (ICER) was calculated, and deterministic and probabilistic sensitivity analyses were performed. RESULTS: Considering cholangiopancreatographies with single-use and reusable duodenoscopes at a cost of €2900 and €1333, respectively, and a 10% rate of single-use duodenoscopes, ICER was greater than €3,000,000/QALY. A lower single-use duodenoscope cost of €1211 resulted in an ICER of €23,583/QALY. When the unit cost of the single-use duodenoscope was €1211, a crossover rate of more than 9.5% made the use of the single-use duodenoscope inefficient. CONCLUSIONS: Single-use duodenoscopes are cost-effective in a proportion of cholangiopancreatographies if its cost is reduced. Increased crossover rate makes single-use duodenoscope use not cost-effective.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Análise de Custo-Efetividade , Desenho de Equipamento
12.
Antimicrob Resist Infect Control ; 13(1): 31, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459544

RESUMO

Contamination of duodenoscopes is a significant concern due to the transmission of multidrug-resistant organisms (MDROs) among patients who undergo endoscopic retrograde cholangiopancreatography (ERCP), resulting in outbreaks worldwide. In July 2020, it was determined that three different patients, all had undergone ERCP with the same duodenoscope, were infected. Two patients were infected with blaCTX-M-15 encoding Citrobacter freundii, one experiencing a bloodstream infection and the other a urinary tract infection, while another patient had a bloodstream infection caused by blaSHV-12 encoding Klebsiella pneumoniae. Molecular characterization of isolates was available as every ESBL-producing isolate undergoes Next-Generation Sequencing (NGS) for comprehensive genomic analysis in our center. After withdrawing the suspected duodenoscope, we initiated comprehensive epidemiological research, encompassing case investigations, along with a thorough duodenoscope investigation. Screening of patients who had undergone ERCP with the implicated duodenoscope, as well as a selection of hospitalized patients who had ERCP with a different duodenoscope during the outbreak period, led to the discovery of three additional cases of colonization in addition to the three infections initially detected. No microorganisms were detected in eight routine culture samples retrieved from the suspected duodenoscope. Only after destructive dismantling of the duodenoscope, the forceps elevator was found to be positive for blaSHV-12 encoding K. pneumoniae which was identical to the isolates detected in three patients. This study highlights the importance of using NGS to monitor the transmission of MDROs and demonstrates that standard cultures may fail to detect contaminated medical equipment such as duodenoscopes.


Assuntos
Duodenoscópios , Sepse , Humanos , Bactérias/genética , beta-Lactamases/genética , Klebsiella pneumoniae/genética , Sequenciamento de Nucleotídeos em Larga Escala
13.
Gut ; 73(4): 613-621, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38182137

RESUMO

OBJECTIVE: Contaminated duodenoscopes caused several hospital outbreaks. Despite efforts to reduce contamination rates, 15% of patient-ready duodenoscopes are still contaminated with gastrointestinal microorganisms. This study aimed to provide an overview of duodenoscope contamination over time, identify risk factors and study the effects of implemented interventions. DESIGN: Duodenoscope culture sets between March 2015 and June 2022 at a Dutch tertiary care centre were analysed. Contamination was defined as (1) the presence of microorganisms of oral or gastrointestinal origin (MGO) or (2) any other microorganism with ≥20 colony-forming units/20 mL (AM20). A logistic mixed effects model was used to identify risk factors and assess the effect of interventions, such as using duodenoscopes with disposable caps, replacing automated endoscope reprocessors (AER) and conducting audits in the endoscopy department. RESULTS: A total of 404 culture sets were analysed. The yearly contamination rate with MGO showed great variation, ranging from 14.3% to 47.5%. Contamination with AM20 increased up to 94.7% by 2022. For both MGO and AM20, the biopsy and suction channels were the most frequently contaminated duodenoscope components. The studied interventions, including audits, AER replacement and implementation of duodenoscopes with disposable caps, did not show a clear association with contamination rates. CONCLUSION: Duodenoscope contamination remains a significant problem, with high contamination rates despite several interventions. Reprocessing the biopsy and suction channels is especially challenging. Changes in the design of reusable duodenoscopes, such as enabling sterilisation or easily replaceable channels, are necessary to facilitate effective duodenoscope reprocessing and to eliminate the risk of duodenoscope-associated infections.


Assuntos
Infecção Hospitalar , Duodenoscópios , Humanos , Colangiopancreatografia Retrógrada Endoscópica , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/epidemiologia , Óxido de Magnésio , Estudos Retrospectivos , Centros de Atenção Terciária
14.
Digestion ; 105(2): 149-156, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198778

RESUMO

INTRODUCTION: Endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (EST) are essential skills for performing endoscopic cholangiopancreatic procedures. However, these procedures have a high incidence of adverse events, and current training predominantly relies on patient-based approaches. Herein, we aimed to develop an ERCP/EST simulator model to address the need for safer training alternatives, especially for learners with limited ERCP experience. METHODS: The model was designed to facilitate the use of actual endoscopic devices, supporting learning objectives that align with the components of the validated Bethesda ERCP Skill Assessment Tool (BESAT). BESAT focuses on skills, such as papillary alignment, maintenance of duodenoscope position, gentle and efficient cannulation, controlled sphincterotomy in the correct trajectory, and guidewire manipulation. Thirty gastroenterology trainees used the simulator between May 2022 and March 2023, and their satisfaction was assessed using a visual analog scale (VAS) and pre- and post-training questionnaires. RESULTS: The novel simulator model comprised a disposable duodenal papillary section, suitable for incision with an electrosurgical knife, alongside washable upper gastrointestinal tract and bile duct sections for repeated use. The duodenal papillary section enabled reproduction of a realistic endoscope position and the adverse bleeding events due to improper incisions. The bile duct section allowed for the reproduction of fluoroscopic-like images, enabling learners to practice guidewire guidance and insertion of other devices. Following training, the median VAS score reflecting the expectation for model learning significantly increased from 69.5 (interquartile range [IQR]: 55.5-76.5) to 85.5 (IQR: 78.0-92.0) (p < 0.01). All participants expressed a desire for repeated simulator training sessions. CONCLUSIONS: This innovative simulator could serve as a practical educational tool, particularly beneficial for novices in ERCP. It could facilitate hands-on practice with actual devices, enhancing procedural fluency and understanding of precise incisions to minimize the risk of bleeding complications during EST.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Esfinterotomia Endoscópica , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Esfinterotomia Endoscópica/efeitos adversos , Esfinterotomia Endoscópica/métodos , Cateterismo/efeitos adversos , Ductos Biliares , Duodenoscópios , Resultado do Tratamento
15.
Am J Infect Control ; 52(3): 331-336, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37776900

RESUMO

BACKGROUND: An inpatient endoscopy unit is a care hub for patients from throughout the hospital and can be the site of health care-associated infections (HAIs). Shared surfaces and other nonmedical devices (keyboards) have been increasingly recognized as sites of pathogen transmission. Beyond standard cleaning of high-touch target areas, we queried whether the addition of automated devices delivering low-intensity doses of ultraviolet (UV)-C radiation could further reduce bioburden in an academic endoscopy unit. METHODS: Bioburden on previously identified high-touch/communal surfaces was measured before and after the installation of automated, low-intensity UV-light emitting devices (UV Angel) that passively monitor and disinfect targeted surfaces with Ultraviolet-C light (UV-C) light. RESULTS: High-touch sites (keyboards) had a baseline bacterial contamination of >80%, whereas individual procedure rooms and common areas had a >57% contamination rate. Following the implementation of automated UV-C light decontamination, bioburden was reduced on average by >91% at high-touch surfaces and within procedure rooms. DISCUSSION/CONCLUSIONS: Nonsterile hubs of patient care could serve as sites of "silent" HAI transmission. We have identified high-touch surfaces within an endoscopy unit that have a high bioburden of bacterial contamination and demonstrated that the installation of passive, automated UV-C light disinfection devices can reduce bioburden significantly, possibly mitigating HAI transmission between patients.


Assuntos
Infecção Hospitalar , Duodenoscópios , Humanos , Atenção Terciária à Saúde , Hospitais , Bactérias , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/microbiologia , Endoscopia Gastrointestinal , Raios Ultravioleta , Desinfecção/métodos
16.
Endoscopy ; 56(3): 198-204, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37848074

RESUMO

BACKGROUND: Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. METHODS: This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention. RESULTS: Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%-52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%-26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11-0.58; P=0.001) CONCLUSIONS: Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.


Assuntos
Duodenoscópios , Óxido de Magnésio , Humanos , Estudos Retrospectivos , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Endoscopia Gastrointestinal
17.
J Gastroenterol Hepatol ; 39(1): 7-17, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37859502

RESUMO

Gastrointestinal (GI) endoscopy is among the highest waste generator in healthcare facilities. The major reasons include production of large-volume non-renewable waste, use of single-use devices, and reprocessing or decontamination processes. Single-use endoscopic accessories have gradually replaced reusable devices over last two decades contributing to the rising impact of GI endoscopy on ecosystem. Several reports of infection outbreaks with reusable duodenoscopes raised concerns regarding the efficacy and adherence to standard disinfection protocols. Even the enhanced reprocessing techniques like double high-level disinfection have not been found to be the perfect ways for decontamination of duodenoscopes and therefore, paved the way for the development of single-use duodenoscopes. However, the use of single-use endoscopes is likely to amplify the net waste generated and carbon footprint of any endoscopy unit. Moreover, single-use devices challenge one of the major pillars of sustainability, that is, "reuse." In the era of climate change, a balanced approach is required taking into consideration patient safety as well as financial and environmental implications. The possible solutions to provide optimum care while addressing the impact on climate include selective use of disposable duodenoscopes and careful selection of accessories during a case. Other options include use of disposable endcaps and development of effective high-level disinfection techniques. The collaboration between the healthcare professionals and the manufacturers is paramount for the development of environmental friendly devices with low carbon footprint.


Assuntos
Mudança Climática , Ecossistema , Humanos , Contaminação de Equipamentos/prevenção & controle , Endoscópios , Duodenoscópios , Desinfecção/métodos , Endoscopia Gastrointestinal
18.
Am J Infect Control ; 52(4): 488-490, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37838249

RESUMO

Over the past decade, infections linked to duodenoscopes have become a significant concern, primarily due to the intricate design of the elevator mechanism. Currently, there is limited evidence regarding the bacterial contamination level of the elevator mechanism after clinical use and throughout its various reprocessing stages. This study utilized the swab culture technique to examine the bacterial contamination on the duodenoscope elevator mechanism after clinical use and after 3 reprocessing stages at a Center of tertiary hospital. Our findings revealed severe bacterial contamination after clinical usage, emphasizing that the effectiveness of manual cleaning greatly influences the subsequent high-level disinfection quality.


Assuntos
Duodenoscópios , Contaminação de Equipamentos , Humanos , Duodenoscópios/microbiologia , Bactérias , Desinfecção/métodos
20.
Hepatobiliary Pancreat Dis Int ; 23(1): 71-76, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37100688

RESUMO

BACKGROUND: Duodenoscope-related multidrug-resistant organism (MDRO) infections raise concerns. Disposable duodenoscopes have been recently introduced in the market and approved by regulatory agencies with the aim to reduce the risk of endoscopic retrograde cholangiopancreatography (ERCP) associated infections. The aim of this study was to evaluate the outcome of procedures performed with single-use duodenoscopes in patients with clinical indications to single-operator cholangiopancreatoscopy. METHODS: This is a multicenter international, retrospective study combining all patients who underwent complex biliopancreatic interventions using the combination of a single-use duodenoscope and a single-use cholangioscope. The primary outcome was technical success defined as ERCP completion for the intended clinical indication. Secondary outcomes were procedural duration, rate of cross-over to reusable duodenoscope, operator-reported satisfaction score (1 to 10) on performance rating of the single-use duodenoscope, and adverse event (AE) rate. RESULTS: A total of 66 patients (26, 39.4% female) were included in the study. ERCP was categorized according to ASGE ERCP grading system as 47 (71.2%) grade 3 and 19 (28.8%) grade 4. The technical success rate was 98.5% (65/66). Procedural duration was 64 (interquartile range 15-189) min, cross-over rate to reusable duodenoscope was 1/66 (1.5%). The satisfaction score of the single-use duodenoscope classified by the operators was 8.6 ± 1.3 points. Four patients (6.1%) experienced AEs not directly related to the single-use duodenoscope, namely 2 post-ERCP pancreatitis (PEP), 1 cholangitis and 1 bleeding. CONCLUSIONS: Single-use duodenoscope is effective, reliable and safe even in technically challenging procedures with a non-inferiority to reusable duodenoscope, making these devices a viable alternative to standard reusable equipment.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite , Humanos , Feminino , Masculino , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos Retrospectivos , Cateterismo , Duodenoscópios/efeitos adversos , Pancreatite/etiologia , Pancreatite/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA