Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69.471
Filtrar
1.
Med Mycol J ; 65(3): 41-47, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39218646

RESUMO

Aspergillus-specific antibodies are diagnostic indicators of allergic bronchopulmonary aspergillosis (ABPA) and chronic pulmonary aspergillosis (CPA). Tests for detecting Aspergillus-specific antibodies were not used clinically in Japan, and the production of the Aspergillus precipitin test was discontinued. Thus, alternative tests for diagnosing aspergillosis are urgently needed. We retrospectively evaluated 64 patients with suspected ABPA and CPA who underwent precipitin antibody testing. Serum Aspergillus IgG levels were measured and compared using the Bordier Aspergillus fumigatus ELISA and the Platelia Aspergillus IgG (Bio-Rad) kits. Of the participants, 18 were diagnosed with CPA, and 8 were diagnosed with ABPA. Both the Bordier and Bio-Rad kits showed high sensitivity and specificity for CPA and ABPA. The area under the receiver operating characteristic curves for the Bordier and Bio-Rad kits were 0.97 and 0.95, respectively, for CPA, and 0.89 and 0.91, respectively, for ABPA. In contrast to the Bordier kit, the Bio-Rad kit showed relatively low anti-Aspergillus IgG levels and lower sensitivity to non-fumigatus Aspergillus infections. The Aspergillus-specific IgG ELISA tests showed sufficient diagnostic accuracy. Therefore, these assays are recommended as alternatives to the precipitin kit for diagnosing aspergillosis in clinical settings in Japan.


Assuntos
Anticorpos Antifúngicos , Ensaio de Imunoadsorção Enzimática , Imunoglobulina G , Aspergilose Pulmonar , Sensibilidade e Especificidade , Humanos , Estudos Retrospectivos , Imunoglobulina G/sangue , Anticorpos Antifúngicos/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Aspergilose Pulmonar/diagnóstico , Aspergilose Pulmonar/imunologia , Adulto , Ensaio de Imunoadsorção Enzimática/métodos , Japão , Aspergillus/imunologia , Idoso de 80 Anos ou mais , Técnicas Imunoenzimáticas/métodos , Aspergilose Broncopulmonar Alérgica/diagnóstico , Aspergilose Broncopulmonar Alérgica/imunologia , Aspergilose Broncopulmonar Alérgica/sangue , Aspergillus fumigatus/imunologia , Curva ROC
2.
Asian Pac J Cancer Prev ; 25(7): 2567-2571, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39068592

RESUMO

BACKGROUND AND AIM: Colorectal cancer (CRC) is considered one of the most common cancers in the world. Serrated polyps were found to be precursor lesions for CRC. BRAF mutation (V600E) has been strongly linked to the development of these lesions. No previous study concerning BRAF immunohistochemical expression in serrated polyps- was done in Oman. The primary objective of our study was to assess the prevalence of BRAF (V600E) mutation in serrated colorectal polyps in the Omani population. The secondary objectives were to assess the prevalence of serrated polyps and their characteristic features: type, site and size as well as the relationship between BRAF (V600E) mutation and polyp type, site and size. MATERIALS AND METHODS: Ninety-one hyperplastic polyps (HP) (76.5%), 24 sessile serrated lesions (SSL) (20.2%) and 4 cases of tubular adenomas with low grade dysplasia (3.4%) were studied for BRAF (V600E) immunohistochemical expression. No case of traditional serrated adenoma (TSA) was present. Control cases of craniopharyngioma and papillary thyroid carcinoma were included. RESULTS: BRAF (V600E) IHC was positive in 63 of the HP polyps (69.2%), 13 SSLs (54.2%) and none of the adenomatous polyps. The majority of positive polyps (75.0%) were ≤5 mm in size, 17.9% were 5-10 mm and 7.1% were ≥10 mm in size.  The majority of BRAF (V600E) positive polyps (68.1 %) were in the distal colon and 31.9 % were in the proximal colon. The majority of positive cases for BRAF (V600E) were showing multiple polyps (61.8 %). None of the tubular adenomas showed any BRAF (V600E) positivity. CONCLUSION: Serrated polyps are now well known for their potential to develop CRC. Immunohistochemistry is an easy and reproducible way to detect BRAF (V600E) mutation. Our study showed there is high prevalence (64.3%) of BRAF mutation in serrated polyps in the Omani population. The majority of these polyps- were HP and SSL; and ≤5 mm in size and located in the distal colon.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Mutação , Proteínas Proto-Oncogênicas B-raf , Humanos , Proteínas Proto-Oncogênicas B-raf/genética , Proteínas Proto-Oncogênicas B-raf/metabolismo , Feminino , Masculino , Omã , Pólipos do Colo/genética , Pólipos do Colo/patologia , Pólipos do Colo/metabolismo , Pessoa de Meia-Idade , Neoplasias Colorretais/genética , Neoplasias Colorretais/patologia , Neoplasias Colorretais/metabolismo , Adulto , Adenoma/genética , Adenoma/patologia , Adenoma/metabolismo , Centros de Atenção Terciária , Prognóstico , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/metabolismo , Idoso , Seguimentos , Estudos de Casos e Controles , Câncer Papilífero da Tireoide/genética , Câncer Papilífero da Tireoide/patologia , Câncer Papilífero da Tireoide/metabolismo , Lesões Pré-Cancerosas/genética , Lesões Pré-Cancerosas/patologia , Lesões Pré-Cancerosas/metabolismo , Adulto Jovem , Neoplasias da Glândula Tireoide/genética , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/metabolismo , Técnicas Imunoenzimáticas , Hiperplasia/genética , Hiperplasia/patologia , Hiperplasia/metabolismo , Carcinoma Papilar/genética , Carcinoma Papilar/patologia , Carcinoma Papilar/metabolismo
3.
Mycopathologia ; 189(4): 67, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023825

RESUMO

BACKGROUND: Galactomannan (GM) testing using Platelia Aspergillus enzyme immunoassay (Platelia AGM) from bronchoalveolar lavage fluid (BALF) aids in early diagnosis of invasive pulmonary aspergillosis (IPA). Globally, only a minority of laboratories have the capability to perform on-site GM testing, necessitating accessible and affordable alternatives. Hence, we conducted a comparative evaluation of the new clarus Aspergillus GM enzyme immunoassay prototype (clarus AGM prototype) with Platelia AGM using BALF samples. METHODS: This is a single-center, prospective, cross-sectional study, where Platelia AGM testing was routinely performed followed by clarus AGM prototype testing in those with true positive or true negative AGM test results according to the 2020 EORTC/MSG and the 2024 FUNDICU consensus definitions. Descriptive statistics, ROC curve analysis, and Spearman's correlation analysis were used to evaluate analytical performance of the clarus AGM prototype assay. RESULTS: This study enrolled 259 adult patients, of which 53 (20%) were classified as probable IPA, while 206 did not fulfill IPA-criteria. Spearman's correlation analysis revealed a strong correlation between the two assays (rho = 0.727, p < 0.001). The clarus AGM prototype had a sensitivity of 96% (51/53) and a specificity of 74% (153/206) for differentiating probable versus no IPA when using the manufacturer recommended cut-off. ROC curve analysis showed an AUC of 0.936 (95% CI 0.901-0.971) for the clarus AGM prototype, while the Platelia AGM yielded an AUC of 0.918 (95% CI 0.876-0.959). CONCLUSIONS: Clarus AGM prototype demonstrated a strong correlation and promising test performance, comparable to Platelia AGM, rendering it a viable alternative in patients at risk of IPA.


Assuntos
Aspergillus , Líquido da Lavagem Broncoalveolar , Galactose , Técnicas Imunoenzimáticas , Aspergilose Pulmonar Invasiva , Mananas , Sensibilidade e Especificidade , Humanos , Mananas/análise , Galactose/análogos & derivados , Líquido da Lavagem Broncoalveolar/microbiologia , Líquido da Lavagem Broncoalveolar/química , Estudos Prospectivos , Aspergilose Pulmonar Invasiva/diagnóstico , Técnicas Imunoenzimáticas/métodos , Estudos Transversais , Pessoa de Meia-Idade , Masculino , Feminino , Aspergillus/isolamento & purificação , Adulto , Idoso , Curva ROC , Adulto Jovem
4.
J Clin Microbiol ; 62(8): e0062924, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39028178

RESUMO

The PATHFAST TB LAM Ag assay is based on a chemiluminescent enzyme immunoassay to quantify lipoarabinomannan (LAM) in sputum within 1 h, and was developed as an alternative to conventional culture methods for monitoring tuberculosis (TB) treatment. This study aimed to evaluate the analytical performance and initial clinical feasibility of using five Mycobacterium tuberculosis variants, 178 non-tuberculous mycobacteria (NTM), 34 upper respiratory and oral cavity microorganisms, 100 sputum specimens from untreated patients, and potential interfering substances, including 27 drugs. The results reveled a single-site repeatability coefficient of variation (CV) of 5.2%-7.0%, and a multi-site reproducibility CV of 7.1%-8.4%. The limit of blank, limit of detection, and limit of quantification were 3.03 pg/mL, 6.67 pg/mL, and 7.44 pg/mL, respectively. Linearity was observed over the analytical measurement range (10.0 pg/mL-50,000 pg/mL), and no hook effect was observed. The assay tended to cross-react with slow-growing NTMs, but not with common upper respiratory and oral cavity microorganisms, except Nocardia asteroides, Nocardia farcinica, and Tsukamurella paurometabola. No interference was observed in the presence of mucin, blood, or major anti-TB, anti-HIV, and anti-pneumonia drugs. Regarding clinical performance, the assay had a sensitivity of 88.8% (95% CI: 80.0%-94.0%) and specificity of 100.0% (95% CI: 83.9%-100.0%) using mycobacterial culture as the reference standard, and a correlation (Spearman's r = -0.770) was observed between LAM concentration and time to detection of culture. These findings show, for the first time, that the PATHFAST TB LAM Ag assay has potential value for monitoring TB treatment.


Assuntos
Lipopolissacarídeos , Sensibilidade e Especificidade , Humanos , Reprodutibilidade dos Testes , Lipopolissacarídeos/análise , Tuberculose/diagnóstico , Tuberculose/microbiologia , Tuberculose/tratamento farmacológico , Escarro/microbiologia , Monitoramento de Medicamentos/métodos , Antígenos de Bactérias/análise , Medições Luminescentes/métodos , Mycobacterium tuberculosis , Técnicas Imunoenzimáticas/métodos
5.
Braz J Infect Dis ; 28(4): 103838, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39009082

RESUMO

Aspergillus species can colonize and infect immunocompetent and immunocompromised hosts. Conventional fungal identification depends on microscopic analysis and microorganism medium growth. Other diagnostic methods, non-growth dependent, to invasive fungal infections, are the biomarkers that detect circulating polysaccharides, for example, 1-3-ß-d-Glucan and galactomannan. Both are polysaccharides present on the external layer of fungi cell wall and can be detected in clinical samples during the growth of the fungus in the patient. This study aimed to compare the galactomannan detection of Lateral Flow Assay and Enzyme Immunoassay methods in Bronchoalveolar Lavage Fluid. The galactomannan antigen in Bronchoalveolar Lavage Fluid was measured using Enzyme Immunoassay according to the manufacturer's instructions (PLATELIA ASPERGILLUS™ BioRad) and, using a Lateral Flow Assay according to the manufacturer's instructions (Galactomannan LFA IMMY©). The 71 samples were Bronchoalveolar Lavage Fluid of patients hospitalized at Unicamp Clinical Hospital between 2019 and 2021; of these samples 12/71 (16.9 %) resulted in positive Galactomannan-Lateral Flow Assay. In contrast, Galactomannan-Enzyme Immunoassay resulted as positive in 9/71 (12.6 %) samples, a difference that showed not significant statistically (p-value = 0.36) Comparing both assays' results identified 8 divergences between them, about 11 % of the total sample. The Sensitivity (73.3 %), Specificity (92.35 %), Positive Predictive Value (62.85 %) and Negative Predictive Value (95.15 %) of Lateral Flow Assay were calculated using the Galactomannan Enzyme Immunoassay as standard. The Lateral Flow Assay demonstrated good results when compared with the Enzyme Immunoassay.


Assuntos
Aspergillus , Líquido da Lavagem Broncoalveolar , Galactose , Técnicas Imunoenzimáticas , Mananas , Sensibilidade e Especificidade , Mananas/análise , Galactose/análogos & derivados , Humanos , Líquido da Lavagem Broncoalveolar/microbiologia , Líquido da Lavagem Broncoalveolar/química , Aspergillus/imunologia , Aspergillus/isolamento & purificação , Técnicas Imunoenzimáticas/métodos , Aspergilose/diagnóstico , Aspergilose/microbiologia , Biomarcadores/análise , Antígenos de Fungos/análise , Reprodutibilidade dos Testes
6.
Anal Sci ; 40(10): 1809-1821, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38884905

RESUMO

Accurate and timely diagnosis of Alzheimer's disease (AD) is necessary to maximize the effectiveness of treatment and using biomarkers for diagnosis is attracting attention as a minimally invasive method with few side effects. Electrochemical immunosensor (EI) is a method that is in the spotlight in the medical and bioanalytical fields due to its portability and field usability. Here, we quantified four AD specific biomarkers using EIs based on enzyme immunoassay. We selected and developed quantitative methods for the biomarkers using screen-printed gold electrodes. For three biomarkers, quantification was performed using competition immunoassays in which antigen-antibody premix mixtures were applied to antigen-immobilized electrodes and the limit of detection (LOD) values were secured, 1.20 ng/ml, 1.30 ng/ml, and 1.74 ng/ml, respectively. For the other, a sandwich immunoassay using antibody pair was selected for quantification and LOD was also achieved as 0.077 ng/ml. All four biomarkers in buffer samples were successfully quantified and reliable R2 values were obtained, and reliable calibration curves were secured for three biomarkers in spiked human serum samples. The immunosensors developed and will be optimized are expected to be used in various fields, including detection of biomarkers for not only AD but also related diseases.


Assuntos
Doença de Alzheimer , Biomarcadores , Técnicas Eletroquímicas , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/sangue , Humanos , Biomarcadores/sangue , Biomarcadores/análise , Técnicas Biossensoriais , Técnicas Imunoenzimáticas/métodos , Eletrodos , Limite de Detecção , Ouro/química , Peptídeos beta-Amiloides/sangue , Peptídeos beta-Amiloides/análise , Peptídeos beta-Amiloides/imunologia
7.
Med Mycol ; 62(7)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38871943

RESUMO

In the present study, we validate and compare the second-generation Miravista Coccidioides IgG and IgM enzyme immunoassays (EIA) (MiraVista Diagnostics [MVD] Ab EIA) to Meridian Diagnostics Coccidioides IgG and IgM EIA (Meridian Ab EIA), immunodiffusion (ID) and complement fixation (CF). We also evaluated whether the addition of Coccidioides antigen testing to anti-Coccidioides antibody testing increased the sensitivity for the diagnosis of currently active coccidioidomycosis. We retrospectively studied 555 patients evaluated at Valleywise Health Medical Center between January 2013 and May 2017 for whom coccidioidomycosis was suspected and samples were submitted to MVD for testing. Specimens were tested for antigen in the MVD antigen enzyme immunoassay (MVD Ag EIA) and for IgG and IgM antibodies with MVD and Meridian Diagnostics EIAs. ID and CF were obtained from medical records. Sensitivity and specificity were 83.0% and 91.1% or MVD Ab EIA, 69.3% and 99.7% for Meridian Ab EIA, 85.4% and 100% for ID and 65.5% and 100% for CF. Combined MVD antigen and antibody detection by EIA and ID resulted in increased sensitivity in disseminated and pulmonary disease (MVD Ag/MVD Ab: 100%, 88.3%; MVD Ag/Meridian Ab: 98.2%, 78.6%; and MVD Ag/ID: 100%, 91.7%). The detection of antibodies by MVD EIA was more sensitive than Meridian EIA or CF but similar to ID. This study supports the use of antigen testing in immunocompromised patients and those with suspected disseminated disease. Furthermore, the addition of antigen detection by EIA to antibody detection resulted in higher sensitivity of all serological tests.


The most common methods for the diagnosis of moderate or severe coccidioidomycosis rely on the detection of antibodies or antigens. Here we present the validation of a new Miravista Coccidioides antibody detection test combined with antigen detection and compare it to other immunodiagnostics.


Assuntos
Anticorpos Antifúngicos , Antígenos de Fungos , Coccidioides , Coccidioidomicose , Técnicas Imunoenzimáticas , Imunoglobulina G , Imunoglobulina M , Sensibilidade e Especificidade , Humanos , Coccidioidomicose/diagnóstico , Coccidioidomicose/imunologia , Antígenos de Fungos/imunologia , Antígenos de Fungos/sangue , Imunoglobulina M/sangue , Estudos Retrospectivos , Imunoglobulina G/sangue , Coccidioides/imunologia , Técnicas Imunoenzimáticas/métodos , Anticorpos Antifúngicos/sangue , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Adulto , Adolescente , Adulto Jovem , Criança , Idoso de 80 Anos ou mais , Pré-Escolar , Imunodifusão , Lactente
8.
J Feline Med Surg ; 26(6): 1098612X241248984, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38857445

RESUMO

OBJECTIVES: The aim of the present study was to evaluate minimally invasive diagnostic techniques, such as the semi-quantitative indirect IgG antibody enzyme immunoassay (EIA) using blood serum and the urinary lateral flow assay (LFA), for the detection of Histoplasma capsulatum in cats with histoplasmosis. METHODS: Eight client-owned domestic cats diagnosed with histoplasmosis were selected based on cytological, histopathological, mycological, molecular or antigenic techniques. The blood serum of these animals was tested in a semi-quantitative indirect IgG antibody EIA for the detection of H capsulatum. Urine samples were tested for H capsulatum antigen using LFA. RESULTS: Five cats were seropositive on IgG EIA (5/8, with diagnostic sensitivity equal to 62.5%; 95% confidence interval [CI] 24.5-91.5) and five cats were positive on H capsulatum antigen LFA (5/7, with diagnostic sensitivity equal to 71.4%; 95% CI 29.0-96.3). The combined diagnostic sensitivity when interpreted in parallel was 87.5% (7/8, 95% CI 47.3-99.7). The specificity for the anti-Histoplasma IgG EIA was 100% (95% CI 71.5-100) and for the H capsulatum antigen LFA it was also 100% (95% CI 71.5-100). CONCLUSIONS AND RELEVANCE: The semi-quantitative indirect IgG antibody EIA for the detection of H capsulatum in blood serum and the urinary LFA for the detection of the same agent emerge as new minimally invasive diagnostic techniques that can assist in the approach to disseminated and pulmonary feline histoplasmosis, especially when both techniques are considered together.


Assuntos
Doenças do Gato , Histoplasma , Histoplasmose , Sensibilidade e Especificidade , Gatos , Animais , Histoplasmose/veterinária , Histoplasmose/diagnóstico , Doenças do Gato/diagnóstico , Doenças do Gato/microbiologia , Histoplasma/isolamento & purificação , Histoplasma/imunologia , Masculino , Feminino , Anticorpos Antifúngicos/sangue , Técnicas Imunoenzimáticas/veterinária , Imunoglobulina G/sangue
9.
Endocr J ; 71(9): 895-906, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-38910122

RESUMO

In Japan, the traditional method for measuring plasma aldosterone concentration (PAC) was radioimmunoassay (RIA), which had several challenges, including poor traceability of certified reference materials and reduced detection sensitivity at low concentrations. To overcome these issues, a chemiluminescent enzyme immunoassay (CLEIA) for PAC measurement was introduced in April 2021 and the Japan Endocrine Society published new guidelines for primary aldosteronism (PA). This study aimed to evaluate the impact of the transition from RIA to CLEIA for PAC measurement on PA diagnosis. Data from 190 patients admitted to the Second Department of Internal Medicine, University of the Ryukyus Hospital, between April 2012 and March 2021 were analyzed. Patients who were diagnosed with PA underwent adrenal venous sampling. The PAC measured by RIA (PAC(RIA)) was converted to the estimated PAC measured by CLEIA (ePAC(CLEIA)) using a conversion formula. The present study evaluated the discordance rates in diagnoses based on screening (SC), captopril challenge test (CCT), saline infusion test (SIT), and diagnosis of PA between results judged by PAC(RIA) according to the previous guidelines and those judged by ePAC(CLEIA) according to the new guidelines. The results revealed discordant diagnosis rates of 6.4% for SC and 10.1% for CCT, with no discordance for SIT. The discordant diagnosis rate for PA was 3.7%. Our study reveals the challenges in establishing appropriate diagnostic criteria for PA using PAC(CLEIA) and highlights the demand for further research on provisionally positive categories.


Assuntos
Aldosterona , Hiperaldosteronismo , Técnicas Imunoenzimáticas , Radioimunoensaio , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangue , Aldosterona/sangue , Japão , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Radioimunoensaio/métodos , Radioimunoensaio/normas , Masculino , Idoso , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Adulto , Medições Luminescentes/métodos
10.
Mycoses ; 67(6): e13756, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38886163

RESUMO

BACKGROUND: Serum galactomannan (GM) testing is essential for diagnosing invasive aspergillosis (IA), particularly in immunocompromised individuals. The global lack of on-site GM testing capacities necessitates cost-effective alternatives, such as .the clarus Aspergillus GM enzyme immunoassay prototype (clarus AGM prototype). METHODS: This single-centre, cross-sectional study compared the diagnostic performance of the clarus AGM prototype (IMMY, Norman, Oklahoma) with the serological gold standard (=Platelia AGM assay; Bio-Rad, Marnes-la-Cocquette, France). IA was classified according to modified 2020 EORTC/MSG consensus and 2024 FUNDICU criteria. In total, 300 prospectively (May-Dec 2023) and retrospectively (2012-2015) collected samples were included. RESULTS: Among 300 samples from 232 patients, 49 (16%) were classified as proven (n = 1) or probable IA (n = 48). In non-IA cases (n = 250), one patient was classified as possible IA. With the manufacturer recommended cut-off of ≥0.2, sensitivity and specificity of the clarus AGM prototype were 27% (13/49; 95% confidence interval [CI]: 15%-41%) and 99% (248/250; 95% CI: 97%-100%), respectively, while sensitivity and specificity were 78% and 79% when using the optimised Youden's cut-off of 0.0045 ODI. ROC curve analysis demonstrated an area under the curve (AUC) of 0.829 (95% CI: 0.760-0.898) for the clarus AGM prototype in distinguishing between proven/probable IA and non-IA. The AUC for the Platelia AGM was 0.951 (95% CI: 0.909-994). Spearman's correlation analysis showed a weak correlation between the two assays (0.382; p < .001). CONCLUSIONS: The weak correlation between the clarus AGM prototype and Platelia AGM highlights the need for further investigation into the clinical performance of the clarus AGM prototype, giving the different antigen epitopes addressed.


Assuntos
Aspergillus , Galactose , Técnicas Imunoenzimáticas , Aspergilose Pulmonar Invasiva , Mananas , Sensibilidade e Especificidade , Humanos , Mananas/sangue , Galactose/análogos & derivados , Aspergilose Pulmonar Invasiva/diagnóstico , Técnicas Imunoenzimáticas/métodos , Estudos Transversais , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Estudos Retrospectivos , Aspergillus/isolamento & purificação , Aspergillus/imunologia , Adulto , Estudos Prospectivos , Antígenos de Fungos/sangue , Idoso de 80 Anos ou mais , Adulto Jovem , Curva ROC
11.
J Am Vet Med Assoc ; 262(9): 1-6, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38848745

RESUMO

OBJECTIVE: To determine the sensitivity and specificity of a commercial whole blood real-time PCR assay (RT-PCR) for the diagnosis of histoplasmosis when compared to direct organism identification and/or urine antigen quantification by enzyme immunoassay (UA-EIA). A secondary objective was to compare the sensitivity and specificity of RT-PCR to anti-Histoplasma immunoglobulin G antibody detection by enzyme immunoassay (IgG-EIA) and IgG-EIA to UA-EIA. ANIMALS: Cats presented to the Kansas State University Veterinary Health Center from February through September of 2023 in which histoplasmosis was diagnosed or suspected. METHODS: From February through September of 2023, cats were tested by RT-PCR, IgG-EIA, and UA-EIA if histoplasmosis was diagnosed cytologically or was a differential diagnosis for the presenting clinical signs. Cats were excluded if all 3 tests were not submitted or if the diagnosis of histoplasmosis could not be excluded despite a negative UA-EIA result. Cats with cytologically or histologically confirmed histoplasmosis were designated as proven histoplasmosis cases, and cats with a positive UA-EIA result without cytological or histological confirmation were designated as probable histoplasmosis cases. RESULTS: 10 cats were diagnosed with either proven (n = 6) or probable (4) histoplasmosis, and 10 cats were considered true negatives. Whole blood RT-PCR results were negative in all 20 cats (sensitivity, 0%; 95% CI, 0% to 30.85%). The IgG-EIA was 90% sensitive (95% CI, 55.50% to 99.75%) and 70% specific (95% CI, 34.75% to 93.33%). The UA-EIA results were positive in all cats with proven histoplasmosis. CLINICAL RELEVANCE: This commercial RT-PCR is insensitive when used on whole blood collected in EDTA and should not be used to diagnose feline histoplasmosis. Further studies are required to determine whether alternate RT-PCR protocols for EDTA-collected whole blood could be useful for diagnosing histoplasmosis in cats.


Assuntos
Doenças do Gato , Histoplasmose , Reação em Cadeia da Polimerase em Tempo Real , Animais , Gatos , Antígenos de Fungos/sangue , Antígenos de Fungos/urina , Doenças do Gato/diagnóstico , Doenças do Gato/sangue , Doenças do Gato/microbiologia , Histoplasma/isolamento & purificação , Histoplasmose/veterinária , Histoplasmose/diagnóstico , Histoplasmose/sangue , Técnicas Imunoenzimáticas/veterinária , Imunoglobulina G/sangue , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Sensibilidade e Especificidade
12.
Food Chem ; 453: 139623, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-38761730

RESUMO

Ochratoxin A (OTA) in food poses a serious challenge to public health. Herein, using the nanobody-driven controllable aggregation of gold nanoparticles (AuNPs) in a glucose oxidase-tyramine-horseradish peroxidase (GOx-TYR-HRP) system, we propose a direct competitive plasmonic enzyme immunoassay (dc-PEIA) for OTA detection. The OTA-GOx conjugate catalyzes glucose to produce hydrogen peroxide (H2O2), and then HRP catalyzes H2O2 to generate hydroxyl radical which induces the crosslink of TYR. Crosslinked TYR leads to aggregation of AuNPs through strong electrostatic interactions, which is tunable based on the competition of OTA-GOx and free OTA for binding the immobilized nanobody. The optimized dc-PEIA achieves an instrumental limit of detection (LOD) of 0.275 ng/mL and a visual LOD of 1.56 ng/mL. It exhibits good selectivity for OTA and accuracy in the analysis of pepper samples, with the confirmation of high-performance liquid chromatography. Overall, the dc-PEIA is demonstrated as a useful tool for detecting OTA in food.


Assuntos
Capsicum , Contaminação de Alimentos , Ouro , Nanopartículas Metálicas , Ocratoxinas , Ocratoxinas/análise , Ouro/química , Nanopartículas Metálicas/química , Capsicum/química , Capsicum/imunologia , Contaminação de Alimentos/análise , Técnicas Imunoenzimáticas/métodos , Limite de Detecção , Glucose Oxidase/química , Anticorpos de Domínio Único/química , Anticorpos de Domínio Único/imunologia , Peroxidase do Rábano Silvestre/química , Técnicas Biossensoriais
13.
J Cataract Refract Surg ; 50(8): 862-867, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38711217

RESUMO

PURPOSE: To investigate the extracellular matrix and cellular components in lens capsules extracted from patients with dead bag syndrome (DBS) through immunohistochemistry. SETTING: Department of Ophthalmology, Wakayama Medical University School of Medicine, Wakayama, Japan, and Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. DESIGN: Immunohistochemical experimental study. METHODS: 9 capsular bag specimens from DBS cases, as well as 2 control specimens from late-postoperative in-the-bag intraocular lens dislocation cases related to previous vitrectomy, pseudoexfoliation, and blunt trauma were included. They were processed for histopathology; unstained sections were obtained from each one and analyzed by immunohistochemistry targeting collagen type IV, laminin, vimentin, collagen type I, and fibronectin. RESULTS: Immunohistochemistry in DBS showed lens capsule stained for basement membrane components. The outer part of the anterior capsule that was split from the inner part was more markedly stained for type IV collagen as compared with the posterior part. Faint staining for fibrous posterior capsular opacification (PCO) components, for example, collagen type I and fibronectin, was detected in limited areas, but the major portion of the capsule was free from these components. Small spotty vimentin-positive materials, suggesting the presence of cell debris, were also detected in limited samples. CONCLUSIONS: Small amounts of fibrotic PCO components were detected in capsules extracted from patients with DBS, but their major parts were free from PCO components. Current findings suggest small amounts of lens epithelial cells were present after surgery and secreted fibrous components before undergoing cell death process.


Assuntos
Colágeno Tipo IV , Colágeno Tipo I , Fibronectinas , Cápsula do Cristalino , Vimentina , Humanos , Colágeno Tipo IV/metabolismo , Fibronectinas/metabolismo , Masculino , Vimentina/metabolismo , Idoso , Feminino , Cápsula do Cristalino/patologia , Cápsula do Cristalino/metabolismo , Pessoa de Meia-Idade , Colágeno Tipo I/metabolismo , Laminina/metabolismo , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/metabolismo , Idoso de 80 Anos ou mais , Facoemulsificação , Síndrome de Exfoliação/metabolismo , Opacificação da Cápsula/metabolismo , Técnicas Imunoenzimáticas , Síndrome , Implante de Lente Intraocular , Adulto
14.
STAR Protoc ; 5(2): 103009, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38602869

RESUMO

Double labeling to identify different markers in the same tissue section represents a useful tool either for in situ diagnosis or characterization of molecular associations. Here, we present a protocol to detect senescence-associated ß-galactosidase (SA-ßGal) and immunoperoxidase (IPO) activity in fresh-frozen murine tissues. We describe steps for tissue collection, solution preparation, SA-ßGal staining, IPO staining, hematoxylin counterstaining, microscopic observation, and signal quantification. This protocol can be used to detect in situ proteins alongside SA-ßGal activity. For complete details on the use and execution of this protocol, please refer to Pacheco-Rivera et al.1.


Assuntos
Senescência Celular , beta-Galactosidase , Animais , beta-Galactosidase/metabolismo , Camundongos , Senescência Celular/fisiologia , Técnicas Imunoenzimáticas/métodos , Coloração e Rotulagem/métodos
15.
Ann Clin Microbiol Antimicrob ; 23(1): 35, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664689

RESUMO

PURPOSE: The clinical significance of negative toxin enzyme immunoassays (EIA) for Clostridioides difficile infections (CDIs) is unclear. Our study aimed to investigate the significance of toxin EIA-negative in the diagnosis and prognosis of CDI. METHODS: All stool specimens submitted for C. difficile toxin EIA testing were cultured to isolate C. difficile. In-house PCR for tcdA, tcdB, cdtA, and cdtB genes were performed using C. difficile isolates. Stool specimens were tested with C. difficile toxins A and B using EIA kit (RIDASCREEN Clostridium difficile toxin A/B, R-Biopharm AG, Darmstadt, Germany). Characteristics and subsequent CDI episodes of toxin EIA-negative and -positive patients were compared. RESULTS: Among 190 C. difficile PCR-positive patients, 83 (43.7%) were toxin EIA-negative. Multivariate analysis revealed independent associations toxin EIA-negative results and shorter hospital stays (OR = 0.98, 95% CI 0.96-0.99, p = 0.013) and less high-risk antibiotic exposure in the preceding month (OR = 0.38, 95% CI 0.16-0.94, p = 0.035). Toxin EIA-negative patients displayed a significantly lower white blood cell count rate (11.0 vs. 35.4%, p < 0.001). Among the 54 patients who were toxin EIA-negative and did not receive CDI treatment, three (5.6%) were diagnosed with CDI after 7-21 days without complication. CONCLUSION: Our study demonstrates that toxin EIA-negative patients had milder laboratory findings and no complications, despite not receiving treatment. Prolonged hospitalisation and exposure to high-risk antibiotics could potentially serve as markers for the development of toxin EIA-positive CDI.


Assuntos
Proteínas de Bactérias , Toxinas Bacterianas , Clostridioides difficile , Infecções por Clostridium , Fezes , Humanos , Clostridioides difficile/genética , Fezes/microbiologia , Masculino , Feminino , Toxinas Bacterianas/análise , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/tratamento farmacológico , Infecções por Clostridium/microbiologia , Idoso , Pessoa de Meia-Idade , Proteínas de Bactérias/genética , Proteínas de Bactérias/análise , Enterotoxinas/análise , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Técnicas Imunoenzimáticas , Adulto , Resultado do Tratamento , Reação em Cadeia da Polimerase , Prognóstico
16.
Sci Rep ; 14(1): 5546, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448541

RESUMO

Biological samples are often frozen and stored for years and/or thawed multiple times, thus assessing their stability on long-term storage and repeated freeze-thaw cycles is crucial. The study aims were to assess:-the long-term stability of two major enzymatic and non-enzymatic metabolites of arachidonic acid, i.e. urinary 11-dehydro-thromboxane-(Tx) B2, 8-iso-prostaglandin (PG)F2α, and creatinine in frozen urine samples;-the effect of multiple freeze-thaw cycles. Seven-hundred and three urine samples measured in previously-published studies, stored at -40 °C, and measured for a second time for 11-dehydro-TxB2 (n = 677) and/or 8-iso-PGF2α (n = 114) and/or creatinine (n = 610) were stable over 10 years and the 2 measurements were highly correlated (all rho = 0.99, P < 0.0001). Urine samples underwent 10 sequential freeze-thaw cycles, with and without the antioxidant 4-hydroxy-2,2,6,6-tetramethylpiperidin-1-oxyl (10 mM); urinary 11-dehydro-TxB2 and creatinine were stable across all cycles (11-dehydro-TxB2: 100.4 ± 21%; creatinine: 101 ± 7% of baseline at cycle ten; n = 17), while 8-iso-PGF2α significantly increased by cycle 6 (151 ± 22% of baseline at cycle ten, n = 17, P < 0.05) together with hydrogen peroxide only in the absence of antioxidant. Arachidonic acid metabolites and creatinine appear stable in human urines stored at -40 °C over 10 years. Multiple freeze-thaw cycles increase urinary 8-iso-PGF2α in urine samples without antioxidants. These data are relevant for studies using urine samples stored over long-term and/or undergoing multiple freezing-thawing.


Assuntos
Antioxidantes , Prostaglandinas F , Humanos , Ácido Araquidônico , Creatinina , Congelamento , Técnicas Imunoenzimáticas , Tromboxanos
17.
PLoS One ; 19(3): e0298730, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38483868

RESUMO

INTRODUCTION: A lateral flow rapid diagnostic test (RDT) enables detection of measles specific immunoglobulin M (IgM) antibody in serum, capillary blood, and oral fluid with accuracy consistent with enzyme immunoassay (EIA). The objectives of the study were: 1) to assess measles RDT inter-reader agreement between two clinic staff; 2) to assess the sensitivity and specificity of the measles RDT relative to standard surveillance testing in a low transmission setting; 3) to evaluate the knowledge, attitudes, and practices of staff in clinics using the RDT; and 4) to assess the impact of RDT testing on the measles public health response in Malaysia. MATERIALS AND METHODS: The clinic-based prospective evaluation included all suspected measles cases captured by routine measles surveillance at 34 purposely selected clinics in 15 health districts in Malaysia between September 2019 and June 2020, following day-long regional trainings on RDT use. Following informed consent, four specimens were collected from each suspected case, including those routinely collected for standard surveillance [serum for EIA and throat swabs for quantitative reverse transcriptase polymerase chain reaction (RT-qPCR)] together with capillary blood and oral fluid tested with RDTs during the study. RDT impact was evaluated by comparing the rapidity of measles public health response between the pre-RDT implementation (December 2018 to August 2019) and RDT implementation periods (September 2019 to June 2020). To assess knowledge, attitudes, and practices of RDT use, staff involved in the public health management of measles at the selected sites were surveyed. RESULTS: Among the 436 suspect cases, agreement of direct visual readings of measles RDT devices between two health clinic staff was 99% for capillary blood (k = 0.94) and 97% for oral fluid (k = 0.90) specimens. Of the total, 45 (10%) were positive by measles IgM EIA (n = 44, including five also positive by RT-qPCR) or RT-qPCR only (n = 1), and 38 were positive by RDT (using either capillary blood or oral fluid). Using measles IgM EIA or RT-qPCR as reference, RDT sensitivity using capillary blood was 43% (95% CI: 30%-58%) and specificity was 98% (95% CI: 96%-99%); using oral fluid, sensitivity (26%, 95% CI: 15%-40%) and specificity (97%, 95% CI: 94%-98%) were lower. Nine months after training, RDT knowledge was high among staff involved with the public health management of measles (average quiz score of 80%) and was highest among those who received formal training (88%), followed by those trained during supervisory visits (83%). During the RDT implementation period, the number of days from case confirmation until initiation of public response decreased by about 5 days. CONCLUSION: The measles IgM RDT shows >95% inter-reader agreement, high retention of RDT knowledge, and a more rapid public health response. However, despite ≥95% RDT specificity using capillary blood or oral fluid, RDT sensitivity was <45%. Higher-powered studies using highly specific IgM assays and systematic RT-qPCR for case confirmation are needed to establish the role of RDT in measles elimination settings.


Assuntos
Sarampo , Testes de Diagnóstico Rápido , Humanos , Imunoglobulina M , Malásia/epidemiologia , Sarampo/diagnóstico , Sarampo/epidemiologia , Técnicas Imunoenzimáticas , Sensibilidade e Especificidade
18.
Med Mycol ; 62(4)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38479779

RESUMO

Definitive diagnosis of histoplasmosis relies on culture and/or cytology/histopathology; however, these procedures have limited sensitivity and cultures are time-consuming. Antibodies detection by immunodiffusion has low sensitivity in immunocompromised individuals and uses histoplasmin (HMN), a crude antigenic extract, as reagent. Novel protein antigen candidates have been recently identified and produced by DNA-recombinant techniques to obtain standardized and specific reagents for diagnosing histoplasmosis. To compare the analytical performance of novel enzyme-linked immunosorbent assays (ELISAs) for antibodies testing for diagnosing histoplasmosis using different Histoplasma capsulatum antigens as reagents. The H. capsulatum 100 kDa protein (Hcp100), the M antigen and its immunoreactive fragment F1 were produced by DNA-recombinant techniques. Galactomannan was purified from both the yeast and mycelial cell walls (yGM and mGM, respectively). The analytical performance of the ELISA tests for the serological detection of antibodies against these antigens was evaluated and compared with those obtained using HMN as reagent. Antibodies detection by the Hcp100 ELISA demonstrated 90.0% sensitivity and 92.0% specificity, versus 43.3% sensitivity and 95.0% specificity of the M ELISA, 33.3% sensitivity and 84.0% specificity of the F1 ELISA, 96.7% sensitivity and 94.0% specificity of the yGM ELISA, 83.3% sensitivity and 88.0% specificity of the mGM ELISA, and 70.0% sensitivity and 86.0% specificity for the HMN ELISA. In summary, Hcp100 is proposed as the most promising candidate for the serodiagnosis of histoplasmosis. The primary immunoreactive element in HMN proved to be GM rather than the M antigen. Nevertheless, a higher incidence of cross-reactions was noted with GM compared to M.


Hcp100 is a promising serodiagnostic candidate for histoplasmosis, boasting high sensitivity and specificity. Notably, GM, rather than M antigen, emerged as the primary immunoreactive element in HMN, despite a higher incidence of cross-reactions with GM compared to M.


Assuntos
Histoplasmose , Humanos , Histoplasmose/diagnóstico , Histoplasmose/veterinária , Histoplasma/genética , Anticorpos Antifúngicos , Técnicas Imunoenzimáticas , Antígenos de Fungos , Anticorpos , Imunodifusão/veterinária , Saccharomyces cerevisiae , DNA
19.
Hypertens Res ; 47(5): 1362-1371, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38454147

RESUMO

The measurement evolution enabled more accurate evaluation of aldosterone production in hypertensive patients. However, the cut-off values for novel assays have been not sufficiently validated. The present study was undertaken to validate the novel chemiluminescent enzyme immunoassay for aldosterone in conjunction with other methods. Moreover, we also aimed to establish a new cut-off value for primary aldosteronism in the captopril challenge test using the novel assay. First, we collected 390 plasma samples, in which aldosterone levels measured using liquid chromatography-mass spectrometry ranged between 0.18 and 1346 ng/dL. The novel chemiluminescent enzyme immunoassay showed identical correlation of plasma aldosterone with liquid chromatography-mass spectrometry, in contrast to conventional radioimmunoassay. Further, we enrolled 299 and 39 patients with primary aldosteronism and essential hypertension, respectively. Plasma aldosterone concentrations measured using the novel assay were lower than those measured by radioimmunoassay, which resulted in decreased aldosterone-to-renin ratios. Subsequently, positive results of the captopril challenge test based on radioimmunoassay turned into "negative" based on the novel assay in 45% patients with primary aldosteronism, using the conventional cut-off value (aldosterone-to-renin activity ratio > 20 ng/dL per ng/mL/h). Receiver operating characteristic curve analysis demonstrated that aldosterone-to-renin activity ratios > 8.2 ng/dL per ng/mL/h in the novel assay was compatible with the conventional diagnosis (sensitivity, 0.874; specificity, 0.980). Our study indicates the great measurement accuracy of the novel chemiluminescent enzyme immunoassay for aldosterone, and the importance of measurement-adjusted cut-offs in the diagnosis of primary aldosteronism.


Assuntos
Aldosterona , Captopril , Hiperaldosteronismo , Medições Luminescentes , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Aldosterona/sangue , Estudos Retrospectivos , Adulto , Idoso , Medições Luminescentes/métodos , Técnicas Imunoenzimáticas/métodos , Hipertensão/sangue , Hipertensão/diagnóstico , Renina/sangue , Estudos de Coortes , Radioimunoensaio
20.
Food Chem ; 443: 138569, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38306906

RESUMO

Zearalenone (ZEN) is a non-steroidal estrogenic mycotoxin and seriously threatens food safety, which requires rapid and sensitive detection methods for monitoring ZEN in agro-products. Herein, an alkaline phosphatase-tagged single-chain variable fragment fusion protein (ALP-scFv) was used as a bifunctional tracer to develop a colorimetric enzyme immunoassay (CEIA) and a chemiluminescent enzyme immunoassay (CLEIA) for ZEN. In addition, the interactions between scFv and ZEN were exploited by computer-assisted simulation, and four key amino acid sites were preliminarily identified. After optimization, the CEIA and CLEIA exhibited a limit of detection of 0.02 and 0.006 ng/mL, respectively. Furthermore, both methods showed favorable accuracy in recovery experiments and good selectivity in cross reactions. Moreover, the detection results of the actual samples from both methods correlated well with those from high-performance liquid chromatography. Overall, the ALP-scFv fusion tracer-based CEIA and CLEIA are demonstrated as reliable tools for ZEN detection in food.


Assuntos
Anticorpos de Cadeia Única , Zearalenona , Fosfatase Alcalina/metabolismo , Zearalenona/análise , Colorimetria , Técnicas Imunoenzimáticas , Corantes/análise , Contaminação de Alimentos/análise , Imunoensaio/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA