Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.564
Filtrar
1.
Clin Oral Investig ; 28(9): 468, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39105859

RESUMO

OBJECTIVE: this study aimed to digitally compare wear behavior and retention between PEEK and nylon retentive inserts used in locator-retained, mandibular implant overdentures when attachment design and size were standardized. MATERIALS AND METHODS: A total of sixty-four inserts (32 PEEK and 32 nylon inserts); were picked-up in implant overdentures. Overdentures of both groups were submerged in artificial saliva and mounted to chewing simulator. After 480,000 chewing cycles (equivalent to 2 years of clinical use) all inserts were scanned by scanning electron microscope (SEM), then all acquired images were digitally analyzed by software to detect and compare quantitative and qualitative changes of inserts in both groups. On the other hand, retention of both groups was measured by universal testing machine and the collected data was statistically analyzed using one-way Analysis of Variance (ANOVA) test with significance level set at P ≤ 0.05. RESULTS: PEEK inserts showed significantly higher mean retentive values compared to the nylon inserts in the control group. Also, PEEK retentive inserts exhibited statistically lower mean wear values than the control group P ≥ 0.000. Qualitative investigation revealed significant and more pronounced changes in the surface roughness of nylon inserts compared to PEEK ones. CONCLUSIONS: Regarding retention, wear behavior and dimension stability, PEEK can be recommended as retentive insert material in cases of locator-retained mandibular implant overdentures. CLINICAL RELEVANCE: PEEK inserts offer enhanced retention, reduced wear, and greater dimensional stability over two years time interval. Clinically, this reduces prosthodontic maintenance and adjustments, improving patient satisfaction and long-term prosthetic success.


Assuntos
Benzofenonas , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Revestimento de Dentadura , Cetonas , Teste de Materiais , Microscopia Eletrônica de Varredura , Nylons , Polietilenoglicóis , Polímeros , Propriedades de Superfície , Cetonas/química , Polietilenoglicóis/química , Humanos , Técnicas In Vitro , Mandíbula , Desgaste de Restauração Dentária , Planejamento de Dentadura , Análise do Estresse Dentário , Saliva Artificial
2.
BMC Oral Health ; 24(1): 885, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095769

RESUMO

BACKGROUND: Immediate rehabilitation is a considerable therapeutic challenge but is necessary for edentulous patients with oronasal fistulas, especially those with inadequate residual bone and a history of radiotherapy. CASE PRESENTATION: We report a rare case of a 63-year-old patient who was missing the majority of his maxillary teeth and who had a defect due to palatal mucoepidermoid carcinoma resection. The patient also received radiotherapy twice within one year postoperatively. An implant-supported prosthesis with an obturator was fabricated immediately. CONCLUSION: This technique improved patients' oral function, enhanced the aesthetic effect, and increased their confidence.


Assuntos
Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Boca Edêntula , Humanos , Pessoa de Meia-Idade , Masculino , Boca Edêntula/reabilitação , Neoplasias Palatinas/cirurgia , Neoplasias Palatinas/reabilitação , Obturadores Palatinos , Planejamento de Dentadura
3.
BMC Oral Health ; 24(1): 946, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39143630

RESUMO

BACKGROUND: Restorative treatment options for edentulous patients range from traditional dentures to fixed restorations. The proper selection of materials greatly influences the longevity and stability of fixed restorations. Most prosthetic parts are frequently fabricated from titanium. Ceramics (e.g. zirconia) and polymers (e.g. PEEK and BIOHPP) have recently been included in these fabrications. The mandibular movement produces complex patterns of stress and strain. Mandibular fractures may result from these stresses and strains exceeding the critical limits because of the impact force from falls or accidents. Therefore, it is necessary to evaluate the biomechanical behavior of the edentulous mandible with different restorations under different loading situations. OBJECTIVE: This study analyzes the biomechanical behavior of mandibles after four prosthetic restorations for rehabilitation under normal and impact loading scenarios. MATERIAL AND METHODS: The mandibular model was constructed with a fixed restoration, which was simulated using various materials (e.g. Titanium, Zirconia & BIOHPP), under frontal bite force, maximum intercuspation, and chin impact force. From the extraction of tensile and compressive stresses and strains, as well as the total deformation of mandible segments, the biomechanical behavior and clinical situations were studied. RESULTS: Under frontal bite, the anterior body exhibited the highest tensile (60.34 MPa) and compressive (108.81 MPa) stresses using restoration 4, while the condyles and angles had the lowest tensile (7.12 MPa) and compressive (12.67 MPa) stresses using restoration 3. Under maximum intercuspation, the highest tensile (40.02 MPa) and compressive (98.87 MPa) stresses were generated on the anterior body of the cortical bone using restoration 4. Additionally, the lowest tensile (7.7 MPa) and compressive (10.08 MPa) stresses were generated on the condyles and angles, respectively, using restoration 3. Under chin impact, the highest tensile (374.57 MPa) and compressive (387.3 MPa) stresses were generated on the anterior body using restoration 4. Additionally, the lowest tensile (0.65 MPa) and compressive (0.57 MPa) stresses were generated on the coronoid processes using restoration 3. For all loading scenarios, the anterior body of the mandible had the highest stress and strain values compared with the other segments. Compared to the traditional titanium restoration.2, restoration.1(zirconia) increases the tensile and compressive stresses and strains on the mandibular segments, in contrast to restoration.3 (BIOHPP). In addition, zirconia implants exhibited higher displacements than the other implants. CONCLUSION: In the normal loading scenario, the tensile and compressive stresses and strains on the mandible were within the allowable limits when all restorations were used. Under the chin impact loading scenario, the anterior body of the mandible was damaged by restorations 1 and 4.


Assuntos
Força de Mordida , Mandíbula , Estresse Mecânico , Titânio , Zircônio , Humanos , Fenômenos Biomecânicos , Materiais Dentários/química , Polietilenoglicóis , Polímeros , Arcada Edêntula/reabilitação , Benzofenonas , Cetonas , Resistência à Tração , Análise de Elementos Finitos , Análise do Estresse Dentário , Força Compressiva , Planejamento de Dentadura
4.
BMC Oral Health ; 24(1): 929, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39127617

RESUMO

BACKGROUND: To evaluate the flexural strength of digitally milled and printed denture base materials. METHODS: The materials tested were Lucitone 199 denture base disc (Dentsply Sirona), AvaDent denture base puck (AvaDent), KeyMill denture base disc (Keystone), Lucitone digital print denture base resin (Dentsply Sirona), Formlab denture base resin (Formlabs), and Dentca base resin II (Dentca). Sixty bar-shaped specimens of each material were prepared for flexural strength testing and were divided into five groups: control, thermocycled, fatigue cycled, and repair using two different materials. The flexural strength and modulus were tested using a 3-point bend test performed on an Instron Universal Testing Machine with a 1kN load cell. The specimens were centered under a loading apparatus with a perpendicular alignment. The loading rate was a crosshead speed of 0.5 mm/min. Each specimen was loaded with a force until failure occurred. A one-way ANOVA test was used to analyze the data, followed by Tukey's HSD test (α = 0.05). RESULTS: The milled materials exhibited higher flexural strength than the printed materials. Thermocycling and fatigue reduce the flexural strengths of printed and milled materials. The repaired groups exhibited flexural strengths of 32.80% and 30.67% of the original flexural strengths of printed and milled materials, respectively. Nevertheless, the type of repair material affected the flexural strength of the printed materials; the composite resin exhibited higher flexural strength values than the acrylic resin. CONCLUSIONS: The milled denture base materials showed higher flexural strength than the printed ones.


Assuntos
Resinas Acrílicas , Análise do Estresse Dentário , Bases de Dentadura , Resistência à Flexão , Teste de Materiais , Resinas Acrílicas/química , Materiais Dentários/química , Módulo de Elasticidade , Planejamento de Dentadura , Propriedades de Superfície , Estresse Mecânico , Maleabilidade , Humanos , Reparação em Dentadura , Impressão Tridimensional , Desenho Assistido por Computador
5.
BMC Oral Health ; 24(1): 983, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39180008

RESUMO

BACKGROUND: While many denture base materials are currently available on the market, little data exists regarding their dimensional stability after exposure to the oral environment. This study aimed to evaluate the effect of thermocycling on the trueness and precision of milled, 3-dimensional (3D)-printed, and conventional digitally fabricated complete denture bases (CDBs). METHODS: A completely edentulous maxillary stone model was scanned to generate a standard tessellation language (STL) file; this was imported into metal-milling-machine software (Redon Hybrid CAD-CAM metal milling machine, Redon, Turkey) to produce a metal model for fabricating 30 CDBs. These were divided into three groups (n = 10 in each) according to the construction technique: group 1, CAD-CAM milled CDBs; group 2, 3D-printed CDBs; and group 3, conventional compression molded CDBs. All CDBs were scanned after fabrication and evaluated before and after thermocycling using superimposition. The data were analyzed using a one-way ANOVA, Tukey's post hoc test, and a paired t-test. RESULTS: The level of trueness between the CAD-CAM milled, 3D-printed, and compression molded CDBs showed significant differences before and after thermocycling (P < 0.05). Group 1 showed the highest degree of trueness before and after thermocycling, group 3 exhibited a higher degree of trueness than group 2 before thermocycling, and group 2 had a higher degree of trueness than group 3 after thermocycling. There was a significant difference in the precision for each CDB type before and after thermocycling (P < 0.05). CONCLUSION: The trueness of the CAD-CAM milling system in complete denture (CD) fabrication is superior to that of the 3D printing and conventional compression molding systems before and after thermocycling. Thermocycling had a significant effect on the precision of all CDB types. The compression molding system in CD construction is the most negatively affected via thermocycling with regard to the measures of trueness and precision. CLINICAL TRIAL NUMBER: Not applicable, no human participants were involved.


Assuntos
Desenho Assistido por Computador , Bases de Dentadura , Planejamento de Dentadura , Impressão Tridimensional , Humanos , Planejamento de Dentadura/métodos , Prótese Total , Modelos Dentários , Temperatura
6.
Am J Dent ; 37(4): 177-182, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39186596

RESUMO

PURPOSE: To evaluate the clinical effect of three impression methods, conventional, closed-mouth, and tissue conditioner, on complete denture fabrication. METHODS: 60 subjects (edentulous with severely resorbed alveolar ridges - Atwood classification III or IV) who visited the Prosthodontic Department of Wuxi Stomatology Hospital, China, between January 2022 and June 2023, were selected for this study. The subjects were randomly divided into three groups of 20: a conventional impression group (CI group), a closed-mouth impression group (CM group), and a tissue conditioner group (TC group). Three months after denture restoration was completed, denture quality was assessed by clinicians in terms of marginal extension, retention, and stability. In addition, patients completed the oral health impact profile-edentulous (OHIP-EDENT) questionnaire to provide subjective satisfaction evaluations of the final denture restoration outcomes. RESULTS: The comprehensive denture quality evaluation results showed that the TC group had the lowest score, which was significantly lower than that of the CM (P= 0.014) and CI (P< 0.001) groups. The average score of the CM group was also significantly lower than that of the CI group (P= 0.004), indicating that tissue conditioner restoration was the most effective method. The OHIP-EDENT scores gradually decreased across the groups from CI to CM to TC (P= 0.001), indicating patients' oral health was significantly improved using tissue conditioner. CLINICAL SIGNIFICANCE: Tissue conditioner is a suitable dynamic functional impression method. It can significantly improve the effects for edentulous patients and increase their satisfaction.


Assuntos
Técnica de Moldagem Odontológica , Planejamento de Dentadura , Prótese Total , Satisfação do Paciente , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Inquéritos e Questionários
7.
J Dent ; 149: 105322, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39191320

RESUMO

OBJECTIVES: This study aimed to evaluate the accuracy of computer-aided design and computer-aided manufacturing (CAD-CAM)-assisted templates (CCAT), guiding rod templates (GRT), and freehand (FH) preparation of guide planes. METHODS: Forty-five identical maxillary resin casts were divided into three groups, in which the guide planes of the two abutment teeth were prepared using a CCAT (n=15), GRT (n=15), and FH (n=15). The CCAT and GRT were digitally designed on a digital cast of virtually prepared guide planes and fabricated using three-dimensional printing (3DP) technology. To assess the 3D trueness, the prepared guide planes were digitally scanned and compared to the virtually designed guide planes. The angle deviation was measured to assess the trueness of the direction of the guide plane preparation. Shapiro-Wilk and Levene's tests were used to check the normality and equivalence of the variance of the data. The data were compared by using the Kruskal‒Wallis H test (α=0.05). RESULTS: The CCAT group exhibited significantly better 3D trueness (78.5±19.8 µm) than the GRT group (211.3±42.4 µm, p<0.05) and the FH group (198.9±44.3 µm, p<0.05). Additionally, the CCAT group (1.31±0.50°) showed significantly smaller direction trueness compared to the GRT (4.65±0.72°, p<0.05) and FH (5.64±0.70°, p<0.05) groups. CONCLUSIONS: The novel CAD-CAM-assisted template significantly improved the quality of the guide planes compared with the GRT and FH procedures. This enhancement suggests that removable partial dentures can be predictably inserted immediately after guide plane preparation. CLINICAL SIGNIFICANCE: CAD-CAM-assisted templates improve the quality of guide plane preparation.


Assuntos
Desenho Assistido por Computador , Planejamento de Dentadura , Prótese Parcial Removível , Impressão Tridimensional , Humanos , Planejamento de Dentadura/métodos , Dente Suporte , Modelos Dentários
8.
J Dent ; 149: 105281, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39094976

RESUMO

OBJECTIVES: This study compared the accuracy of seven intraoral scanners (IOS) by the virtual-fit method. METHODS: Four maxillary arches with tooth abutments were scanned with an industrial reference scanner (n=1) and by Aoralscan3, EmeraldS, Helios600, Lumina, Mediti700, Primescan, and Trios5 IOSs (each n=12). Two complete-arch fixed frameworks were designed on each IOS scan with a 70 µm (group 70) and a 90 µm internal cement space (group 70+20, additional 20 µm at the margin). The virtual-fit method was comprised of superimposing the framework designs onto the reference scan using a non-penetrating algorithm simulating the clinical try-in. Internal and marginal gaps were measured. Precision was estimated by the mean absolute errors (MAE). RESULTS: In group 70, Mediti700 (43 µm), Primescan (42 µm), and EmeraldS were in the best homogenous subset for the marginal gap, followed by the Lumina (67 µm), Aoralscan3 (70 µm), and Trios5 (70 µm), whereas Helios600 (118 µm) was in the third subset. Based on the MAE at the margin, Mediti700, Trios5, and EmeraldS were in the first-best homogenous subset, followed by Primescan. Lumina and Helios600 were in the third subset, and Aoralscan3 was in the fourth subset. In group 70+20, the marginal gap was significantly decreased for Lumina and Aoralscan3, whereas MAE significantly decreased for EmeraldS and Aoralscan3. The rank of IOSs was similar for the internal gap. CONCLUSION: EmeraldS, Mediti700, Primescan, and Trios5 meet the marginal and internal fit criteria for fixed tooth-borne complete arch restorations. Increasing the cement space during design could enhance restoration fit. CLINICAL SIGNIFICANCE: The virtual-fit alignment method can effectively evaluate the accuracy of different intraoral scanners, offering valuable clinical guidance for distinguishing among them. Recent software and hardware versions of long-standing IOS manufacturers are suitable for fabricating complete arch restoration.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Humanos , Arco Dental/diagnóstico por imagem , Arco Dental/anatomia & histologia , Algoritmos , Maxila/diagnóstico por imagem , Adaptação Marginal Dentária , Planejamento de Dentadura/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos
9.
J Dent ; 148: 105253, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-39029614

RESUMO

OBJECTIVES: to assess the survival rates of removable partial dentures (RPDs) and identify factors impacting their longevity. METHODS: electronic health records were retrieved of patients aged ≥18 who received RPDs between 2010 - 2021 with a follow-up of ≥ three months. Data extracted included demographics, medical history, dental charting, periodontal screening and recording scores, prostheses details and related interventions, including new dentures/denture remakes, and maintenance. Multivariate Mixed-Effect Cox regression was performed to identify potential RPD survival risk factors. Reduced model selection was reached using a backward step-down by comparing the performance of these multivariable models using the ANOVA test. RESULTS: 1893 RPDs from 1246 patients were included, with a median follow-up of 21.8 months (range from 3 to 131.3 months). Three hundred and twelve patients received a maxillary RPD, 460 received a mandibular RPD, and the remaining 474 patients received both maxillary and mandibular RPDs. Metal-based RPDs had a median survival of 73 months (95%CI: 70 - 82) versus 45 months (95% CI: 37-67) for acrylic ones. Multivariable mixed effects Cox model showed that the lifespans of RPDs were longer amongst patients receiving more maintenance care within three months [Hazards Ratio (HR)=0.89 (0.83, 0.96)] and after three months [HR=0.53 (0.46, 0.61)] of denture delivery, patients wearing both maxillary and mandibular RPDs [HR=0.67 (0.52, 0.87)], and patients receiving metal-based RPDs [HR=0.31 (0.23, 0.42)]. CONCLUSIONS: Metal-based dentures, dual arch restoration, and increased maintenance positively impact the survival of RPDs. CLINICAL SIGNIFICANCE: Adapting consent and warranty practices is advised to reflect RPD performance variations.


Assuntos
Ligas de Cromo , Prótese Parcial Removível , Humanos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Adulto , Resinas Acrílicas , Planejamento de Dentadura , Falha de Restauração Dentária , Análise de Sobrevida , Fatores de Risco , Cobalto , Seguimentos , Retenção de Dentadura , Modelos de Riscos Proporcionais , Maxila
10.
BMC Oral Health ; 24(1): 760, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965507

RESUMO

BACKGROUND: Preservation of the remaining structures while maintaining an esthetic appearance is a major objective in removable partial prosthodontics. So, the aim of the current study was to compare the stresses induced on the supporting structures by two digitally produced esthetic core materials; Zirconia and Polyetheretherketone when used as an extracoronal attachment in distal extension removable partial dentures using strain gauge analysis. METHODS: A mandibular Kennedy class II stone cast with the necessary abutments' preparations was scanned. The mandibular left canine and first premolar teeth were virtually removed. An acrylic mandibular left canine and first premolar teeth were prepared with heavy chamfer finish line and scanned. Virtual superimposition of the acrylic teeth in their corresponding positions was done. Two strain gauge slots were designed: distal to the terminal abutment and in the residual ridge. Two models and two sets of scanned teeth were digitally printed. The printed teeth were then placed in their corresponding sockets in each model and scanned. The attachment design was selected from the software library and milled out of Zirconia in the model ZR and Polyetheretherketone in the model PE. Five removable partial dentures were constructed for each model. The strain gauges were installed in their grooves. A Universal testing machine was used for unilateral load application of 100 N (N). For each removable partial denture, five measurements were made. The data followed normal distribution and were statistically analyzed by using unpaired t test. P value < 0.05 was considered to be statistically significant. RESULTS: During unilateral loading unpaired t test showed statistically significant difference (p = 0.0001) in the microstrain values recorded distal to the abutment between the models ZR (-1001.6 µÎµ ± 24.56) and PE (-682.6 µÎµ ± 22.18). However, non statistically significant difference (p = 0.3122) was observed in the residual ridge between them; ZR (16.2 µÎµ ± 4.53) and PE (15 µÎµ ± 3.74). CONCLUSIONS: In removable partial dentures, Polyetheretherketone extracoronal attachment induces less stress on the supporting abutments compared to the zirconia one with no difference in the stresses induced by them on the residual ridge.


Assuntos
Benzofenonas , Planejamento de Dentadura , Prótese Parcial Removível , Cetonas , Polímeros , Zircônio , Cetonas/química , Humanos , Zircônio/química , Polietilenoglicóis , Análise do Estresse Dentário , Materiais Dentários/química , Desenho Assistido por Computador , Dente Suporte , Estresse Mecânico , Estética Dentária , Teste de Materiais
12.
J Prosthet Dent ; 132(3): 645.e1-645.e7, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39013679

RESUMO

STATEMENT OF PROBLEM: The impact of thermal cycling on the flexure strength of contemporary denture base materials remains inadequately understood despite its crucial role in determining the long-term performance of complete dentures. PURPOSE: The purpose of this in vitro study was to evaluate the flexural strength of different CAD-CAM denture base materials and the effects of thermal cycling. MATERIAL AND METHODS: A total of 120 rectangular specimens were fabricated from 6 denture base materials according to the International Organization for Standardization (ISO) 20795-1:2013 standard: a heat-compressed PMMA ([Lucitone 199 [C-L199]), 2 brands of milled material (Ivotion Base [M-IB] and Lucitone Digital Fit [M-LDF]), and 3 types of 3- dimensionally (3D) printed material (Lucitone Digital Print [P-LDP], Flexcera Base [P-FB], and FotoDent Dentures [P-FD]). Specimens were divided into 2 subgroups of 10; half underwent thermocycling, half did not. Thermally cycled specimens were immersed in distilled water at 37 °C for 2 days, followed by 5000 thermal cycles at 5 and 55 ºC, with a dwell time of 30 seconds. They were then subjected to a 3-point flexural strength test. Two-way ANOVA, followed by post hoc Tukey multiple comparison tests were used to assess the effect of material type and the thermal cycling process on the flexural strength of denture base materials (α=.05). RESULTS: All materials met the ISO standard of 65 MPa flexural strength, except for thermal cycled P-FB. A significant difference (P<.05) in flexure strength value was found among various denture base materials without thermal cycling (M-LDF>M-IB≈P-FD≈P-LDP>C-L199≈ P-FB) and with thermal cycling (M-LDF> M-IB≈P-FD>P-LDP≈C-L199>P-FB). The flexural strength of tested materials was reduced significantly (P<.05) with thermal cycling. CONCLUSIONS: Three-dimensionally printed denture base materials have a flexural strength value similar to or less than that of milled denture base materials. Thermal cycling impacts the flexural strength of denture base materials.


Assuntos
Desenho Assistido por Computador , Bases de Dentadura , Resistência à Flexão , Teste de Materiais , Técnicas In Vitro , Análise do Estresse Dentário , Materiais Dentários/química , Impressão Tridimensional , Polimetil Metacrilato/química , Planejamento de Dentadura , Humanos , Temperatura
13.
J Dent ; 149: 105267, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39067647

RESUMO

AIM: The positive impact of implant interventions on dental patient-reported outcomes is an essential parameter of treatment effectiveness. This study assessed the 2-year changes in patient satisfaction and oral health-related quality of life (OHRQoL) of edentulous patients treated with a four mini implant mandibular overdenture (IOD) METHODS: The study was planned as a 2 × 2 factorial randomized clinical trial that tested two surgical approaches (flapped or flapless) and two loading protocols (immediate and delayed) using a titanium-zirconium mini implant (Straumann Mini Implant System®) and a PEEK retentive system (Straumann® Optiloc® Retentive System). Outcome measures (OHIP-Edent scores and the McGill Denture Satisfaction questionnaire) were assessed before treatment and at the 3-, 6-, 12-, and 24-month follow-ups. The Friedman test and multiple regression using Generalized Estimating Equations (GEE) were used for data analysis, considering the per-protocol (PP) and intention-to-treat (ITT) approaches RESULTS: Seventy-four patients were randomized to the study groups. No implant failure occurred during the study period. Marked improvement in all post-treatment periods compared to baseline were observed for the two outcomes. No significant effect of patient's gender, age, and surgical protocol on the study outcomes. The effect of treatment provision was significant for the two outcomes in the PP and ITT approaches (p < 0.001). A barely significant positive effect of the immediate loading was observed for OHIP-Edent in the PP approach (p = 0.020) CONCLUSION: IOD treatment significantly improved patient-reported outcomes measures, with sustained benefits over the two years of overdenture use, and can be considered a promising treatment option in for the edentulous mandible.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Arcada Edêntula , Mandíbula , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Qualidade de Vida , Titânio , Zircônio , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Mandíbula/cirurgia , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia , Retenção de Dentadura , Resultado do Tratamento , Prótese Total Inferior , Planejamento de Dentadura , Saúde Bucal , Carga Imediata em Implante Dentário
14.
J Dent ; 149: 105266, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39067651

RESUMO

OBJECTIVE: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS: 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION: The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Retenção de Dentadura , Revestimento de Dentadura , Titânio , Zircônio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Seguimentos , Estudos Prospectivos , Retenção de Dentadura/instrumentação , Idoso , Resultado do Tratamento , Mandíbula/cirurgia , Planejamento de Dentadura , Reparação em Dentadura , Prótese Total Inferior
15.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(4): 481-485, 2024 Aug 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-39049636

RESUMO

OBJECTIVES: This study aimed to evaluate the application of digital impression and resin model technology in removable partial dentures (RPD) for Kennedy classⅠandⅡdentition defects. METHODS: Patients with Kennedy classⅠorⅡdental defect were selected and grouped in accordance with the following denture production processes: digital impression/resin model/cast cobalt-chromium alloy framework group (group A), digital impression/resin model/laser printed titanium framework group (group B), alginate impression/plaster model/cast cobalt-chromium alloy framework group (group C), and alginate impression/plaster model/laser printed titanium framework group (group D), with 40 cases in each group. The final RPD was examined in place in the mouth, and the evaluation indicators included the retention force of clamp ring, the tightness of connector and base, and the accuracy of occlusion. The evaluation scores of each index were used for analysis on the Kruskal-Wallis rank-sum test. RESULTS: No statistically significant difference in the score of each index was found among the four groups in RPD. CONCLUSIONS: The cast cobalt-chromium alloy and laser-printed titanium framework RPD using digital impression and resin model can meet the clinical restoration requirements of patients with Kennedy classⅠandⅡdentition defects.


Assuntos
Técnica de Moldagem Odontológica , Planejamento de Dentadura , Prótese Parcial Removível , Humanos , Ligas de Cromo , Titânio , Lasers , Desenho Assistido por Computador
16.
J Prosthet Dent ; 132(2): 434.e1-434.e6, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38845279

RESUMO

STATEMENT OF PROBLEM: The success of a removable partial denture depends on its fit, and, with conventional casting, the framework is more distorted in patients with a deep palatal vault. Questions remain about whether the three-dimensional (3D) printing technique for fabricating a framework can improve the accuracy of fit for these patients. PURPOSE: The purpose of this in vitro study was to compare the trueness of metal frameworks fabricated by selective laser melting, 3D printing pattern casting, and conventional casting for different palatal vault depths. MATERIAL AND METHODS: A total of 30 partially edentulous maxillary casts were custom-made in 15 medium and 15 deep palatal vaults. All stone casts were scanned as reference models in digital files. For the medium palatal vault casts, Co-Cr frameworks of the conventional casting (CON) group (n=5) were fabricated with the lost wax technique. For the 3D printing pattern casting (PPC) group (n=5), wax patterns of the framework were printed, followed by metal casting. The frameworks created for the selective laser melting (SLM) group (n=5) were printed directly by using the SLM machine. The same procedures were followed for the deep palatal vault group. All the metal frameworks were scanned and superimposed with the reference casts by using the Geomagic Control X software program. Discrepancies were measured as mean ±standard deviation (trueness), and the data were statistically analyzed with a 2-way ANOVA test to evaluate the interaction of 2 independent factors (fabrication techniques and palatal vault depths) on a trueness outcome (α=.05). RESULTS: The lowest mean ±standard deviation value was 0.092 ±0.023 mm, found from the SLM framework with deep palatal vault group, while the highest value was 0.194 ±0.017 mm, found from the CON framework with deep palatal vault group. Different fabrication techniques interacted with different palatal vault depths in terms of trueness (P<.05); however, no significant differences were observed in the medium palatal vault groups (P>.05). Additionally, color mapping demonstrated the gaps of metal frameworks among the 6 groups. CONCLUSIONS: With the conventional casting technique, the accuracy of the metal framework was affected by the depth of the palate. For medium palatal vaults, all fabricated frameworks had clinically acceptable fit. For deep palatal vaults, the SLM frameworks showed the lowest discrepancy. As a result, the SLM technique is advised for fabricating a better-fitting metal framework for patients with a deep palatal vault.


Assuntos
Técnica de Fundição Odontológica , Planejamento de Dentadura , Prótese Parcial Removível , Impressão Tridimensional , Humanos , Planejamento de Dentadura/métodos , Técnicas In Vitro , Desenho Assistido por Computador , Modelos Dentários
17.
J Dent ; 147: 105140, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38901823

RESUMO

OBJECTIVES: To evaluate the longevity of cantilevered zirconia-based resin-bonded fixed partial dentures (RBFPDs) in replacing missing posterior teeth, as well as the quality of life and patient satisfaction experienced by those receiving zirconia RBFPDs. METHODS: A prospective single-arm uncontrolled clinical trial was conducted to replace one or more missing premolars or molars with a span of 5 to 8 mm using cantilevered zirconia RBFPDs. Thirty-six participants with 40 prostheses were recruited and underwent a 3-year clinical evaluation. The retainer designs included a minimum thickness of 0.8 mm, a minimum of 200° circumferential wraparound with an occlusal bar, and a connector dimension of 3 × 3 mm. Patient-reported outcomes, including patient satisfaction and Oral Health Impact Profile (OHIP), were assessed. RESULTS: The average age of participants was 45.8 years, and 72.5 % were women. The success rate of the posterior zirconia RBFPDs was 76.2 %, with an estimated mean success duration of 46.1 months. The survival rate was 88.1 %, with an estimated mean survival duration of 49.4 months. Participants were highly satisfied with the treatment, achieving an average satisfaction score of 80.8 ± 11.9. Participants' total OHIP scores decreased from 52.3 to 39.6 after 3 years, indicating a significant improvement in oral health-related quality of life (P = 0.009). CONCLUSIONS: After 3 years, a moderately high survival rate and favourable patient-reported outcomes of posterior cantilevered zirconia RBFPDs were achieved. Therefore, it can be recommended as a conservative treatment option to replace missing posterior teeth, provided that retainer design considerations are taken into account. CLINICAL SIGNIFICANCE: Cantilevered zirconia RBFPDs for posterior teeth can serve as a conservative treatment option that is both aesthetically pleasing and biocompatible. It offers a more cost-effective alternative compared to dental implants, which are often prohibitively expensive for the majority of patients. This approach has the potential to greatly improve patient-reported outcomes.


Assuntos
Planejamento de Dentadura , Prótese Adesiva , Dente Molar , Satisfação do Paciente , Qualidade de Vida , Zircônio , Humanos , Zircônio/química , Feminino , Estudos Prospectivos , Masculino , Pessoa de Meia-Idade , Adulto , Dente Pré-Molar , Resultado do Tratamento , Retenção de Dentadura , Falha de Restauração Dentária , Materiais Dentários/química , Idoso
18.
Indian J Dent Res ; 35(1): 101-103, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38934758

RESUMO

ABSTRACT: Rehabilitation of partially edentulous arches with a cast partial denture is a commonly opted treatment modality where fixed prosthesis is not indicated. However, due to the aesthetic compromise of the various metal components when placed in the esthetic zone, different modifications have been considered for its fabrication. This case report describes a novel way of restoring partially edentulous arches with increased masticatory efficiency and good emergence profile without compromising the patient's esthetic desires. The report describes an aesthetic alternative using thermoplastic denture base clasp like extension for anterior abutment teeth while restoring the missing teeth with a cast partial denture.


Assuntos
Dente Suporte , Bases de Dentadura , Planejamento de Dentadura , Humanos , Arcada Parcialmente Edêntula/reabilitação , Estética Dentária , Grampos Dentários , Feminino , Masculino
19.
BMC Oral Health ; 24(1): 671, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38851680

RESUMO

The latest generation of intraoral scanners can record the prosthetic field with relative ease, high accuracy and comfort for the patient, and have enabled fully digital protocols for designing and manufacturing complete dentures. The present study aims to examine the intaglio surface trueness of 3D printed maxillary dentures produced by fully digital workflow in comparison with dentures produced by analogue clinical and laboratory prosthetic workflow. The edentulous maxillary arch of 15 patients was scanned with an intraoral scanner as well as the intaglio of the delivered conventional denture. The scan of the edentulous arch was imported into a dental design software to produce the denture base which was then 3D printed. The intaglio surface of the finished 3D printed denture bases was digitized and used to assess the trueness of the printed denture bases compared to the intaglio surface of the conventional dentures as well as performing a trueness comparison in relation to the scanned edentulous arches. The dataset (n = 30) was subjected to Kruskal-Wallis test analysis, the significance level being established at α = 0.05. The results of the study showed that the printed group displayed better trueness values with a median of 176.9 µm while the analogue group showed a median of 342 µm. Employing a fully digital workflow to produce 3D-printed denture bases yields a consistent and precise manufacturing method when accounting for the intaglio surface of the denture.


Assuntos
Bases de Dentadura , Planejamento de Dentadura , Impressão Tridimensional , Fluxo de Trabalho , Humanos , Planejamento de Dentadura/métodos , Desenho Assistido por Computador , Feminino , Arcada Edêntula , Prótese Total Superior
20.
J Long Term Eff Med Implants ; 34(4): 33-47, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38842231

RESUMO

This virtual study was designed to evaluate the stress-deformation of a metal fixed partial dentures (FPDs) pontic under different loads using two different connectors. The STL file was generated for a RPD of two implant-supported restorations. The Co-Cr metal substructure was designed with two types of connector design. The pontic is connected to implant-supported crowns with square and round shape connectors. This study was designed for a cementless-retained implant-supported FPD. Finite element modeling (FEM) is used to assess the stress and deformation of the pontic within a metal substructure as the FEM might provide virtual values that could have laboratory and clinical relevance. The Co-Cr alloy mechanical properties like the Poisson ratio and modulus of elasticity were based on the parameters of the three-dimensional structure additive method. Nonparametric analyses (Mann-Whitney U test) was used. The use of square or round connectors often resulted in non-significant changes in stress, and deformation under either three or each loaded point on the occlusal surface of a pontic (P > 0.05). However, the deformation revealed distinct variations between loads of the three points compared to each loaded point (P ≤ 0.05). According to this study data, the pontic occlusal surface appears to be the same in stress and deformation under different loads depending on whether square or round connectors are used. While at the same connector designs, the pontic occlusal surface deformed significantly at three loaded points than it did at each point.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Análise de Elementos Finitos , Humanos , Ligas de Cromo/química , Planejamento de Dentadura , Análise do Estresse Dentário , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA