Comparison of safety and effectiveness of micropulse transscleral cyclophotocoagulation and "slow cook" diode laser transscleral cyclophotocoagulation in patients with refractory open-angle glaucoma
Arq. bras. oftalmol
; Arq. bras. oftalmol;88(1): e2023, 2025. tab, graf
Article
in En
|
LILACS-Express
| LILACS
| ID: biblio-1568843
Responsible library:
BR1.1
ABSTRACT
ABSTRACT Purpose:
This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma.Methods:
We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B).Results:
We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was −0.10 ± 0.35 and −0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001).Conclusion:
Both techniques reduced intraocular pressure effectively.
Full text:
1
Collection:
01-internacional
Database:
LILACS
Language:
En
Journal:
Arq Bras Oftalmol
/
Arq. bras. oftalmol
/
Arq. bras. oftalmol. (Online)
/
Arquivos brasileiros de oftalmologia (Impresso)
Journal subject:
OFTALMOLOGIA
Year:
2025
Document type:
Article
Affiliation country:
Country of publication: