Time-scale detection of microemboli in flowing blood with Doppler ultrasound.
Krongold, B S; Sayeed, A M; Moehring, M A; Ritcey, J A; Spencer, M P; Jones, D L.
Affiliation
  • Krongold BS; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign 61801, USA. krongold@uiuc.edu
IEEE Trans Biomed Eng ; 46(9): 1081-9, 1999 Sep.
Article in En | MEDLINE | ID: mdl-10493071
ABSTRACT
Small formed elements and gas bubbles in flowing blood, called microemboli, can be detected using Doppler ultrasound. In this application, a pulsed constant-frequency ultrasound signal insonates a volume of blood in the middle cerebral artery, and microemboli moving through its sample volume produce a Doppler-shifted transient reflection. Current detection methods include searching for these transients in a short-time Fourier transform (STFT) of the reflected signal. However, since the embolus transit time through the Doppler sample volume is inversely proportional to the embolus velocity (Doppler-shift frequency), a matched-filter detector should in principle use a wavelet transform, rather than a short-time Fourier transform, for optimal results. Closer examination of the Doppler shift signals usually shows a chirping behavior apparently due to acceleration or deceleration of the emboli during their transit through the Doppler sample volume. These variations imply that a linear wavelet detector is not optimal. We apply linear and quadratic time-frequency and time-scale detectors to a set of noise-corrupted embolus data. Our results show improvements of about 1 dB using the time-scale detectors versus an STFT-based detector signifying that embolus detection is best approached as a time-scale problem. A time-scale-chirp detector is also applied and is found to have the overall best performance by about 0.5-0.7 dB while coming fairly close (about 0.75 dB) to a theoretical upper bound.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Signal Processing, Computer-Assisted / Intracranial Embolism and Thrombosis / Ultrasonography, Doppler Type of study: Diagnostic_studies Limits: Humans Language: En Journal: IEEE Trans Biomed Eng Year: 1999 Document type: Article Affiliation country:
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Signal Processing, Computer-Assisted / Intracranial Embolism and Thrombosis / Ultrasonography, Doppler Type of study: Diagnostic_studies Limits: Humans Language: En Journal: IEEE Trans Biomed Eng Year: 1999 Document type: Article Affiliation country: