Validation of an atomic absorption rubidium ion efflux assay for KCNQ/M-channels using the ion Channel Reader 8000.
Wang, Kewei; McIlvain, Beal; Tseng, Eugene; Kowal, Dianne; Jow, Flora; Shen, Ru; Zhang, Howard; Shan, Qin Jennifer; He, Lan; Chen, Diana; Lu, Qiang; Dunlop, John.
Affiliation
  • Wang K; Discovery Neuroscience, Wyeth Research, CN-8000, Princeton, NJ 08543, USA. wangk@wyeth.com
Assay Drug Dev Technol ; 2(5): 525-34, 2004 Oct.
Article in En | MEDLINE | ID: mdl-15671650
M-channels (M-current), encoded by KCNQ2/3 K(+) channel genes, have emerged as novel drug targets for a number of neurological disorders. The lack of direct high throughput assays combined with the low throughput of conventional electrophysiology (EP) has impeded rapid screening and evaluation of K(+)-channel modulators. Development of a sensitive and efficient assay for the direct measurement of M-current activity is critical for identifying novel M-channel modulators and subsequent investigation of their therapeutic potential. Using a stable CHO cell line expressing rat KCNQ2/3 K(+) channels confirmed by EP, we have developed and validated a nonradioactive rubidium (Rb(+)) efflux assay in a 96-well plate format. The Rb(+) efflux assay directly measures the activity of functional channels by atomic absorption spectroscopy using the automated Ion Channel Reader (ICR) 8000. The stimulated Rb(+) efflux from KCNQ2/3-expressing cells was blocked by the channel blockers XE991 and linopirdine with IC(50) values of 0.15 microM and 1.3 microM, respectively. Twelve compounds identified as KCNQ2/3 openers were further assessed in this assay, and their EC(50) values were compared with those obtained with EP. A higher positive correlation coefficient between these two assays (r = 0.60) was observed than that between FlexStation membrane potential and EP assays (r = 0.23). To simplify the assay and increase the throughput, we demonstrate that EC(50) values obtained by measuring Rb(+) levels in the supernatant are as robust and consistent as those obtained from the ratio of Rb(+) in supernatant/lysate. By measuring the supernatant only, the throughput of ICR8000 in an eight-point titration is estimated to be 40 compounds per day, which is suitable for a secondary confirmation assay.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Rubidium / Spectrophotometry, Atomic / Potassium Channels, Voltage-Gated Limits: Animals Language: En Journal: Assay Drug Dev Technol Journal subject: FARMACOLOGIA Year: 2004 Document type: Article Affiliation country: Country of publication:
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Rubidium / Spectrophotometry, Atomic / Potassium Channels, Voltage-Gated Limits: Animals Language: En Journal: Assay Drug Dev Technol Journal subject: FARMACOLOGIA Year: 2004 Document type: Article Affiliation country: Country of publication: