Your browser doesn't support javascript.
loading
[Analysis of variability in determining intact parathyroid hormone (iPTH) according to the method used to process the sample]. / Análisis de la variabilidad en la determinación de la hormona paratiroidea (PTH-i) según el método empleado para procesar la muestra.
Morales García, A I; Górriz Teruel, J L; Plancha Mansanet, M C; Escudero Quesada, V; Pallardó Mateu, L M.
Affiliation
  • Morales García AI; Servicio de Nefrología, Hospital Universitario Dr. Peset, Valencia. amoralesg@senefro.org
Nefrologia ; 29(4): 331-5, 2009.
Article in Es | MEDLINE | ID: mdl-19668305
BACKGROUND: The measurement of i-PTH circulating is not easy due to its analytical variablity. Variability that appears in the process that goes from the sample collection to the final result determination. There are several important aspects that can influence within the pre-test variability: type of sample (serum o plasma), temperature, time elapses from blood extraction to freezing and from freezing to i-PTH quantification. Blood coming from centres far from our laboratory do not always meet the required processing conditions. Our aim was to study the stability of i-PTH with varying conditions of temperature and time until freezing in patients with chronic kidney disease (CKD). METHODS: We have analyzed 294 blood samples of 49 patients with chronic kidney disease (18 transplantated patients (36.7%) and 31 patients in haemodyalisis (63.3%)). The blood samples were collected using tubes treated with ethylenediaminotetraacetic acid (EDTA); these samples were subjected to different conditions of temperature and time before they were frozen, constituting 6 groups: blood centrifuged and plasma immediately frozen (group A or reference group); blood maintained 1 hour at room temperature and plasma stored at 2-8 masculineC during 0, 8 and 24 hours (groups B,C,D); blood maintained 3 hours at room temperature and plasma stored at 2-8 masculineC during 0 and 8 hours (groups E,F). The intact PTH (i-PTH) was measured using the immunoradiometric assay (IRMA Total Intact Scantibodies assay). We have analyzed the differences between the PTH-i mean values in the referenced groud and the others. We have applied the tests of homogeneity variance and normality and we have perform a comparation by pairs with the t-test including the Bonferroni correction. RESULTS: The mean value of intact-PTH in the referente Group was 202.5+/-199.72 pg/ml. The means values of intact-PTH in the other groups were 196 +/- 203.23 pg/ml, 202.8 +/- 200.2 pg/ml, 200.06 +/- 194.87 pg/ml, 204.08 +/- 204.073 pg/ml, 197.94 +/- 182.31 pg/ml. The results were practically identical for each group. We did not find important differences with respect to the reference group (p = 0.87, p = 0,99, p = 0,95, p = 0,96, p = 0,90 when comparing with groups 2a, 2b, 2c, 3a y 3b). CONCLUSIONS: The use of EDTA maintain the PTH stability during a longer period without the necessity of freezing the samples immediately. These results can help to state strategies to management the samples in patients with ERC.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Parathyroid Hormone Limits: Adult / Female / Humans / Male / Middle aged Language: Es Journal: Nefrologia Year: 2009 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Parathyroid Hormone Limits: Adult / Female / Humans / Male / Middle aged Language: Es Journal: Nefrologia Year: 2009 Document type: Article Country of publication: