Your browser doesn't support javascript.
loading
Percutaneous decompression of lumbar spinal stenosis with a new interspinous device.
Masala, Salvatore; Fiori, Roberto; Bartolucci, Dario Alberto; Volpi, Tommaso; Calabria, Eros; Novegno, Federica; Simonetti, Giovanni.
Affiliation
  • Masala S; Department of Diagnostic and Molecular Imaging, Interventional Radiology, Nuclear Medicine and Radiation Therapy, University of Rome Tor Vergata, viale Oxford 81, 00133, Rome, Italy.
Cardiovasc Intervent Radiol ; 35(2): 368-74, 2012 Apr.
Article in En | MEDLINE | ID: mdl-21626258
OBJECTIVE: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. METHODS: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. RESULTS: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. CONCLUSIONS: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prostheses and Implants / Spinal Stenosis / Decompression, Surgical / Lumbar Vertebrae Type of study: Diagnostic_studies / Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Cardiovasc Intervent Radiol Year: 2012 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prostheses and Implants / Spinal Stenosis / Decompression, Surgical / Lumbar Vertebrae Type of study: Diagnostic_studies / Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Cardiovasc Intervent Radiol Year: 2012 Document type: Article Affiliation country: Country of publication: