High-throughput method for a kinetics analysis of the high-pressure inactivation of microorganisms using microplates.
Hasegawa, Toshimi; Hayashi, Manabu; Nomura, Kazuki; Hayashi, Mayumi; Kido, Miyuki; Ohmori, Tsuneo; Fukuda, Masao; Iguchi, Akinori; Ueno, Shigeaki; Shigematsu, Toru; Hirayama, Masao; Fujii, Tomoyuki.
Affiliation
  • Hasegawa T; Department of Food Science, Faculty of Applied Life Sciences, Niigata University of Pharmacy and Applied Life Sciences, 265-1 Higashijima, Akiha-ku, Niigata, Niigata 956-8603, Japan.
J Biosci Bioeng ; 113(6): 788-91, 2012 Jun.
Article in En | MEDLINE | ID: mdl-22382011
ABSTRACT
Using microplates as pressure and cultivation vessels, a high-throughput method was developed for analyzing the high-pressure inactivation kinetics of microorganisms. The loss of viability from a high-pressure treatment, measured based on the growth delay during microplate cultivation, showed reproducibility with the conventional agar plate method and was applicable for the kinetics analysis.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pressure / Disinfection / Microbial Viability Language: En Journal: J Biosci Bioeng Journal subject: ENGENHARIA BIOMEDICA / MICROBIOLOGIA Year: 2012 Document type: Article Affiliation country: