PURPOSE:

After total disc replacement with a ball-and-socket joint, reduced range of motion and progression of facet joint degeneration at the index level have been described. The aim of the study was to test the hypothesis that misalignment of the vertebrae adjacent to the implant reduces range of motion and increases facet joint or capsule tensile forces.

METHODS:

A probabilistic finite element analysis was performed using a lumbosacral spine model with an artificial disc at level L5/S1. Misalignment of the L5 vertebra, the gap size of the facet joints, the transection of the posterior longitudinal ligament, and the spinal shape were varied. The model was loaded with pure moments.

RESULTS:

Misalignment of the L5 vertebra reduced the range of motion up to 2°. A 2-mm displacement of the L5 vertebra in the anterior direction already led to facet joint forces of approximately 240 N. Extension, lateral bending, and axial rotation caused maximum facet joint forces between 280 and 380 N, while flexion caused maximum forces of approximately 200 N. A 2-mm displacement in the posterior direction led to capsule forces of approximately 80 N. Additional moments increased the maximum facet capsule forces to values between 120 and 230 N.

CONCLUSIONS:

Misalignment of the vertebrae adjacent to an artificial disc strongly increases facet joint or capsule forces. It might, therefore, be an important reason for unsatisfactory clinical results. In an associated clinical study (Part 2), these findings are validated.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sacrum / Finite Element Analysis / Total Disc Replacement / Intervertebral Disc / Lumbar Vertebrae Type of study: Prognostic_studies Limits: Humans Language: En Journal: Eur Spine J Journal subject: ORTOPEDIA Year: 2013 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sacrum / Finite Element Analysis / Total Disc Replacement / Intervertebral Disc / Lumbar Vertebrae Type of study: Prognostic_studies Limits: Humans Language: En Journal: Eur Spine J Journal subject: ORTOPEDIA Year: 2013 Document type: Article
...