Your browser doesn't support javascript.
loading
A comparison of the response of PADC neutron dosemeters in high-energy neutron fields.
Trompier, F; Boschung, M; Buffler, A; Domingo, C; Cale, E; Chevallier, M-A; Esposito, A; Ferrarini, M; Geduld, D R; Hager, L; Hohmann, E; Mayer, S; Musso, A; Romero-Esposito, M; Röttger, S; Smit, F D; Sashala Naik, A; Tanner, R; Wissmann, F; Caresana, M.
Affiliation
  • Trompier F; Institute for Radiological Protection and Nuclear Safety, BP 17, Fontenay-aux-Roses F-92262, France francois.trompier@irsn.fr.
  • Boschung M; Radiation Metrology Section, Paul Scherrer Institute (PSI), Villigen CH-5232, Switzerland.
  • Buffler A; Department of Physics, University of Cape Town, Rondebosch 7700, South Africa.
  • Domingo C; Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Cale E; Institute for Radiological Protection and Nuclear Safety, BP 40035, Le Vésinet F-78116, France.
  • Chevallier MA; Institute for Radiological Protection and Nuclear Safety, BP 17, Fontenay-aux-Roses F-92262, France.
  • Esposito A; IFNF-LNF, FISMEL, via E. Fermi 40, Frascati 00044, Italy.
  • Ferrarini M; CNAO, Via Privata Campeggi, Pavia 27100, Italy.
  • Geduld DR; Department of Physics, University of Cape Town, Rondebosch 7700, South Africa iThemba Laboratory for Accelerator Based Sciences, Somerset West 7129, South Africa.
  • Hager L; Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ, UK.
  • Hohmann E; Radiation Metrology Section, Paul Scherrer Institute (PSI), Villigen CH-5232, Switzerland.
  • Mayer S; Radiation Metrology Section, Paul Scherrer Institute (PSI), Villigen CH-5232, Switzerland.
  • Musso A; Institute for Radiological Protection and Nuclear Safety, BP 40035, Le Vésinet F-78116, France.
  • Romero-Esposito M; Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Röttger S; Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, Braunschweig 38116, Germany.
  • Smit FD; iThemba Laboratory for Accelerator Based Sciences, Somerset West 7129, South Africa.
  • Sashala Naik A; Dipartimento di Energia, Politecnico di Milano, CESNEF, via Ponzio 34/3, Milano 20133, Italy Mi.Am srl via De Amicis 5, Fabiano di Rivergaro, PC 29029, Italy.
  • Tanner R; Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ, UK.
  • Wissmann F; Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, Braunschweig 38116, Germany.
  • Caresana M; Mi.Am srl via De Amicis 5, Fabiano di Rivergaro, PC 29029, Italy.
Radiat Prot Dosimetry ; 161(1-4): 78-81, 2014 Oct.
Article in En | MEDLINE | ID: mdl-24298170
ABSTRACT
Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutron fields. Irradiations were performed at the iThemba LABS facility in South Africa with neutrons having energies up to 66 and 100 MeV.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Radiation Protection / Radiation Monitoring / Neutrons Limits: Humans Country/Region as subject: Africa / Europa Language: En Journal: Radiat Prot Dosimetry Year: 2014 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Radiation Protection / Radiation Monitoring / Neutrons Limits: Humans Country/Region as subject: Africa / Europa Language: En Journal: Radiat Prot Dosimetry Year: 2014 Document type: Article Affiliation country:
...