Your browser doesn't support javascript.
loading
Quality control assurance of strontium-90 in foodstuffs by LSC.
Lopes, I; Mourato, A; Abrantes, J; Carvalhal, G; Madruga, M J; Reis, M.
Affiliation
  • Lopes I; Instituto Superior Técnico, Campus Tecnológico e Nuclear, Laboratório de Proteção e Segurança Radiológica, Estrada Nacional 10 (ao km 139,7), Bobadela LRS 2695-066, Portugal. Electronic address: ilopes@ctn.ist.utl.pt.
  • Mourato A; Instituto Superior Técnico, Campus Tecnológico e Nuclear, Laboratório de Proteção e Segurança Radiológica, Estrada Nacional 10 (ao km 139,7), Bobadela LRS 2695-066, Portugal.
  • Abrantes J; Instituto Superior Técnico, Campus Tecnológico e Nuclear, Laboratório de Proteção e Segurança Radiológica, Estrada Nacional 10 (ao km 139,7), Bobadela LRS 2695-066, Portugal.
  • Carvalhal G; Instituto Superior Técnico, Campus Tecnológico e Nuclear, Laboratório de Proteção e Segurança Radiológica, Estrada Nacional 10 (ao km 139,7), Bobadela LRS 2695-066, Portugal.
  • Madruga MJ; Instituto Superior Técnico, Campus Tecnológico e Nuclear, Laboratório de Proteção e Segurança Radiológica, Estrada Nacional 10 (ao km 139,7), Bobadela LRS 2695-066, Portugal.
  • Reis M; Instituto Superior Técnico, Campus Tecnológico e Nuclear, Laboratório de Proteção e Segurança Radiológica, Estrada Nacional 10 (ao km 139,7), Bobadela LRS 2695-066, Portugal.
Appl Radiat Isot ; 93: 29-32, 2014 Nov.
Article in En | MEDLINE | ID: mdl-24560851
ABSTRACT
A method based on the separation of Sr-90 by extraction chromatography and beta determination by Liquid Scintillation Counting (LSC) technique was used for strontium analysis in food samples. The methodology consisted in prior sample treatment (drying and incineration) followed by radiochemical separation of Sr-90 by extraction chromatography, using the Sr-resin. The chemical yield was determined by gravimetric method, adding stable strontium to the matrix. Beta activity (Sr-90/Y-90) was determined using a low background liquid scintillation spectrometer (Tri-Carb 3170 TR/SL, Packard). The accuracy and the precision of the method, was performed previously through recovery trials with Sr-90 spiked samples, using the same type of matrices (milk, complete meals, meat and vegetables). A reference material (IAEA_321) was now used to measure the accuracy of the procedure. Participation in interlaboratory comparison exercises was also performed in order to establish an external control on the measurements and to ensure the adequacy of the method.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Scintillation Counting / Strontium Radioisotopes / Food Contamination, Radioactive Type of study: Evaluation_studies Limits: Humans Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2014 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Scintillation Counting / Strontium Radioisotopes / Food Contamination, Radioactive Type of study: Evaluation_studies Limits: Humans Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2014 Document type: Article