Your browser doesn't support javascript.
loading
Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair.
Weiser, Lukas; Nüchtern, Jakob V; Sellenschloh, Kay; Püschel, Klaus; Morlock, Michael M; Rueger, Johannes M; Hoffmann, Michael; Lehmann, Wolfgang; Großterlinden, Lars G.
Affiliation
  • Weiser L; Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany. l.weiser@uke.de.
  • Nüchtern JV; Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany.
  • Sellenschloh K; Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany.
  • Püschel K; Institute of Forensic Medicine, Hamburg-Eppendorf University Medical Center, Hamburg, Germany.
  • Morlock MM; Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany.
  • Rueger JM; Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany.
  • Hoffmann M; Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany.
  • Lehmann W; Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany.
  • Großterlinden LG; Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 2025-2031, 2017 Jul.
Article in En | MEDLINE | ID: mdl-26685688
ABSTRACT

PURPOSE:

To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints.

METHODS:

An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing.

RESULTS:

Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.).

CONCLUSION:

Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Orthopedic Fixation Devices / Acromioclavicular Joint / Materials Testing / Joint Dislocations / Surgical Tape / Ligaments, Articular Type of study: Clinical_trials Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Knee Surg Sports Traumatol Arthrosc Journal subject: MEDICINA ESPORTIVA / TRAUMATOLOGIA Year: 2017 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Orthopedic Fixation Devices / Acromioclavicular Joint / Materials Testing / Joint Dislocations / Surgical Tape / Ligaments, Articular Type of study: Clinical_trials Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Knee Surg Sports Traumatol Arthrosc Journal subject: MEDICINA ESPORTIVA / TRAUMATOLOGIA Year: 2017 Document type: Article Affiliation country: