ABSTRACT

PURPOSE:

To develop and assess a "hybrid" method that combines a first-pass analytical approach and the Patlak plot (PP) to improve assessment of low blood-brain barrier permeability from dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) data. MATERIALS AND

METHODS:

Seven patients with vestibular schwannoma were enrolled. T1 -W DCE imaging was acquired on a 1.5T scanner. Normal-appearing white matter (NAWM) was divided into four regions of interest (ROIs) based on the magnitude of changes in longitudinal relaxation rate (ΔR1) after gadolinium administration. Kinetic analysis of ROI-averaged contrast agent concentration curves was performed using both the conventional PP and the hybrid method. Computer simulated uptake curves that resemble those from NAWM were analyzed with both methods. Percent deviations (PD) of the "measured" values from the "true" values were calculated to evaluate accuracy and precision of the two methods.

RESULTS:

The simulation showed that, at a noise level of 4% (a noise level similar to the in vivo data) and using a signal intensity (SI) averaging scheme, the new hybrid method achieved a PD of 0.9 ± 2.7% for vp , and a PD of -5.4 ± 5.9% for Ktrans . In comparison, the PP method obtained a PD of 3.6 ± 11.3% for vp , and -8.3 ± 12.8% for Ktrans . One-way analyses of variance (ANOVAs) showed significant variations from the four WM regions (P < 10-15 for ΔR1; P < 10-6 for Ktrans ; P < 10-4 for vp ).

CONCLUSION:

Both computer simulation and in vivo studies demonstrate improved reliability in vp and Ktrans estimates with the hybrid method. LEVEL OF EVIDENCE 3 Technical Efficacy Stage 1 J. MAGN. RESON. IMAGING 2017;4679-93.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Capillary Permeability / Blood-Brain Barrier / Neuroma, Acoustic / Magnetic Resonance Angiography / Diffusion Magnetic Resonance Imaging / Multimodal Imaging / White Matter Type of study: Diagnostic_studies / Prognostic_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: J Magn Reson Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2017 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Capillary Permeability / Blood-Brain Barrier / Neuroma, Acoustic / Magnetic Resonance Angiography / Diffusion Magnetic Resonance Imaging / Multimodal Imaging / White Matter Type of study: Diagnostic_studies / Prognostic_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: J Magn Reson Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2017 Document type: Article Affiliation country: