Your browser doesn't support javascript.
loading
The Bond Strength of Nanohybrid and Nanoceramic Composites to Feldspathic Porcelain.
Özdemir, Hatice; Yanikoglu, Nuran Dinçkal.
Affiliation
  • Özdemir H; Department of Prosthodontics, Faculty of Dentistry, Atatürk University, Erzurum, Turkey.
  • Yanikoglu ND; Department of Prosthodontics, Faculty of Dentistry, Atatürk University, Erzurum, Turkey.
Contemp Clin Dent ; 8(4): 558-564, 2017.
Article in En | MEDLINE | ID: mdl-29326506
ABSTRACT

BACKGROUND:

Porcelain fracture is the most important problem in fixed prosthetic restorations. The replacement of fractured restoraions isn't often prefer by patients and dentists. Intraoral repair of fractured porcelain is a big alternative for patient and dentist. For this reason, dentists try to improve different surface treatments to increase the bond strength between porcelain and repair materials such as composite resins.

AIMS:

The aim of this study was to evaluate the shear bond strength (SBS) of nano-hybrid (Nh.com) and nano-ceramic composite resins (Nc.com) to this feldspathic porcelains (Vita and Ivoclar). SETTINGS AND

DESIGN:

120 ceramic disc were fabricated from feldspathic porcelain. MATERIALS AND

METHODS:

The following surface treatment was applied on the ceramic surface 1) Hydrofluoric acid+silane, 2) Air-abrasion+silane, 3) Air-abrasion=Control group. Nh.com and Nc.com was placed on the porcelain surface. Half of the specimens were stored in 37 ± 2oC distilled water and another half were subjected to thermocycling before SBS. The samples placed in an universal testing machine and applied shear force until seperation occured. STATISTICAL ANALYSIS USED The data were analyzed by multi-way analysis of variance (ANOVA) and Duncan test (P <0.05).

RESULTS:

The results show that Ivoclar and Vita had almost equal fracture values. Nh.com showed high bond strength than Nc.com. In the Ivoclar porcelain, hydrofluoric acid etching had highest fracture values than other surface treatments, and in the vita porcelain air-abrasion had a little difference from hydrofluoric acid etching.

CONCLUSIONS:

Different surface treatments show different effect on SBS between feldspathic porcelain and composite resins.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Contemp Clin Dent Year: 2017 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Contemp Clin Dent Year: 2017 Document type: Article Affiliation country: