Your browser doesn't support javascript.
loading
Motion artifacts in standard clinical setting obscure disease-specific differences in quantitative susceptibility mapping.
Meineke, J; Wenzel, F; De Marco, M; Venneri, A; Blackburn, D J; Teh, K; Wilkinson, I D; Katscher, U.
Affiliation
  • Meineke J; Tomographic Imaging, Philips Research Europe, Hamburg, Germany.
Phys Med Biol ; 63(14): 14NT01, 2018 07 09.
Article in En | MEDLINE | ID: mdl-29897342
ABSTRACT
As quantitative susceptibility mapping (QSM) is maturing, more clinical applications are being explored. With this comes the question whether QSM is sufficiently robust and reproducible to be directly used in a clinical setting where patients are possibly not cooperative and/or unable to suppress involuntary movements sufficiently. Twenty-nine patients with Alzheimer's disease, 31 patients with mild cognitive impairment and 41 healthy controls were scanned on a 3 T scanner, including a multi-echo gradient-echo sequence for QSM and an inversion-prepared segmented gradient-echo sequence (T1-TFE, MPRAGE). The severity of motion artifacts (excessive/strong/noticeable/invisible) was categorized via visual inspection by two independent raters. Quantitative susceptibility was reconstructed using 'joint background-field removal and segmentation-enhanced dipole inversion', based on segmented subcortical gray-matter regions, as well as using 'morphology enabled dipole inversion'. Statistical analysis of the susceptibility maps was performed per region. A large fraction of the data showed motion artifacts, visible in both magnitude images and susceptibility maps. No statistically significant susceptibility differences were found between groups including motion-affected data. Considering only subjects without visible motion, significant susceptibility differences were observed in caudate nucleus as well as in putamen. Motion-effects can obscure statistically significant differences in QSM between patients and controls. Additional measures to restrict and/or compensate for subject motion should be taken for QSM in standard clinical settings to avoid risk of false findings.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Brain Mapping / Magnetic Resonance Imaging / Artifacts / Alzheimer Disease / Movement Type of study: Observational_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Phys Med Biol Year: 2018 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Brain Mapping / Magnetic Resonance Imaging / Artifacts / Alzheimer Disease / Movement Type of study: Observational_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Phys Med Biol Year: 2018 Document type: Article Affiliation country: