Lead: a hidden "untested" risk in neonatal blood transfusion.
Aly, Sanaa Mohamed; Omran, Ahmed; Abdalla, Mohamed Osama; Gaulier, Jean-Michel; El-Metwally, Dina.
Affiliation
  • Aly SM; Forensic Medicine and Clinical Toxicology Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt. sasydayem@hotmail.com.
  • Omran A; Pediatrics and Neonatology Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt.
  • Abdalla MO; Clinical Pathology Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt.
  • Gaulier JM; CHU Lille, Unité Fonctionnelle de Toxicologie, F-59000, Lille, France.
  • El-Metwally D; Pediatrics and Neonatology Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt.
Pediatr Res ; 85(1): 50-54, 2019 01.
Article in En | MEDLINE | ID: mdl-30297876
ABSTRACT

BACKGROUND:

Neonates may be exposed to lead (Pb) through blood transfusions from donors. Pb exposure has neurological, cardiovascular, renal, and other adverse effects. The study aimed to (i) determine the blood lead levels (BLLs) in different blood product units (whole blood, packed red blood cells (pRBCs), platelets, and plasma transfused to neonates) and (ii) estimate the proportion of units with high BLLs.

METHODS:

Residual blood from blood bank bags that were used for neonatal transfusion were collected 25 samples from each type of blood product except for whole blood (10 samples). The Pb analysis was performed using the atomic absorption method. The study was conducted at the Suez Canal University Hospital, Egypt.

RESULTS:

The mean of BLL in pRBCs, platelets, plasma, and whole blood were 136, 199, 108, and 130 µg/L, respectively; 60% contained Pb above 50 µg/L. The highest BLLs were in platelet units.

CONCLUSIONS:

The present study showed for the first time that platelets and plasma in addition to whole blood and pRBCs used for neonatal transfusions are sources of Pb. Re-evaluation of the guidelines is mandatory for the safety of the neonates. Long-term neurodevelopment assessment of neonates exposed to high Pb is warranted.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Banks / Blood Donors / Blood Platelets / Blood Transfusion / Erythrocytes / Lead / Lead Poisoning Type of study: Etiology_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male / Middle aged / Newborn Country/Region as subject: Africa Language: En Journal: Pediatr Res Year: 2019 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Banks / Blood Donors / Blood Platelets / Blood Transfusion / Erythrocytes / Lead / Lead Poisoning Type of study: Etiology_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male / Middle aged / Newborn Country/Region as subject: Africa Language: En Journal: Pediatr Res Year: 2019 Document type: Article Affiliation country: