Your browser doesn't support javascript.
loading
SESAME: A TOOL FOR NUMERICAL DOSIMETRIC RECONSTRUCTION OF PATIENTS OVEREXPOSURES IN INTERVENTIONAL RADIOLOGY.
Huet, Christelle; Entine, Fabrice; Bassinet, Céline; Dondey, Matthieu; Dreuil, Serge; Georges, Jean-Louis; Etard, Cécile; Clairand, Isabelle.
Affiliation
  • Huet C; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
  • Entine F; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
  • Bassinet C; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
  • Dondey M; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
  • Dreuil S; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
  • Georges JL; Service de Cardiologie, Centre Hospitalier de Versailles André Mignot, 177 rue de Versailles, 78150 Le Chesnay, France.
  • Etard C; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
  • Clairand I; Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Santé et Environnement, 31 Avenue de la Division Leclerc, 92260 Fontenay-aux- Roses, France.
Radiat Prot Dosimetry ; 185(2): 231-238, 2019 Dec 23.
Article in En | MEDLINE | ID: mdl-30753615
ABSTRACT
Radiation overexposure accidents are rare but can have severe health consequences. Evaluating the dose received by the patient is a crucial step in the medical management. For that purpose, for more than 15 years, IRSN has been developing an in-house tool named SESAME for the numerical reconstruction of radiological accidents due to external sources. Recently, two new functionalities were implemented in SESAME to allow accurate reconstructions of interventional radiology (IR) overexposures. The experimental validation of SESAME for the reconstruction of overexposures in IR is presented. First, an anthropomorphic dummy equipped with dosemeters was irradiated following conditions similar to a fluoroscopically guided interventional procedure. Then the procedure was simulated using SESAME. Finally measured doses were compared to calculated doses. Even with a limited amount of data available, SESAME can provide valuable dose information for the medical team in charge of the patient, such as skin dose mapping and dose distribution in depth.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiation Protection / Software / Radiation Monitoring / Risk Assessment / Radioactive Hazard Release / Radiation Exposure / Phantoms, Imaging Type of study: Etiology_studies / Risk_factors_studies Limits: Humans Language: En Journal: Radiat Prot Dosimetry Year: 2019 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiation Protection / Software / Radiation Monitoring / Risk Assessment / Radioactive Hazard Release / Radiation Exposure / Phantoms, Imaging Type of study: Etiology_studies / Risk_factors_studies Limits: Humans Language: En Journal: Radiat Prot Dosimetry Year: 2019 Document type: Article Affiliation country: