Your browser doesn't support javascript.
loading
Carbon Quantum Dot-Modified Carbon Paste Electrode-Based Sensor for Selective and Sensitive Determination of Adrenaline.
Shankar, S Sharath; Shereema, Rayamarakkar M; Ramachandran, Vishnu; Sruthi, T V; Kumar, V B Sameer; Rakhi, R B.
Affiliation
  • Shankar SS; Chemical Sciences & Technology Division (CSTD), CSIR-National Institute for Interdisciplinary Science & Technology (CSIR-NIIST), Trivandrum 695019, India.
  • Shereema RM; Department of Biochemistry & Molecular Biology, Central University of Kerala, Periye, Kasaragod 671316, India.
  • Ramachandran V; Chemical Sciences & Technology Division (CSTD), CSIR-National Institute for Interdisciplinary Science & Technology (CSIR-NIIST), Trivandrum 695019, India.
  • Sruthi TV; Department of Biochemistry & Molecular Biology, Central University of Kerala, Periye, Kasaragod 671316, India.
  • Kumar VBS; Department of Biochemistry & Molecular Biology, Central University of Kerala, Periye, Kasaragod 671316, India.
  • Rakhi RB; Department of Biochemistry & Molecular Biology, Central University of Kerala, Periye, Kasaragod 671316, India.
ACS Omega ; 4(4): 7903-7910, 2019 Apr 30.
Article in En | MEDLINE | ID: mdl-31459878
A carbon quantum dot-based carbon paste electrode was fabricated and used for the determination of adrenaline (AD) at the nanomolar level. This fabricated electrode exhibited tremendous electrocatalytic activity for the oxidation of adrenaline in supporting electrolyte (PBS of pH 7.4). Scan rate variation studies with the modified electrode revealed that the overall electrode process was controlled by a diffusion process. A lower detection limit of 6 nM was achieved by chronoamperometry. Interference by biological molecules such as serotonin (5-HT) and ascorbic acid (AA) in the electrochemical oxidation of AD on the fabricated electrode was tested. It was observed that with the modified electrode, the selective determination of AD was possible. Further, with the fabricated electrode, simultaneous analysis of AA, AD, and 5-HT was performed, and it was observed that the overlapped peaks of these analytes on the naked electrode were well resolved into three peaks on the modified electrode. Along with decent sensitivity and selectivity, the electrode also showed higher stability and antifouling nature. The real-time application of the projected scheme was proven by employing the said electrode for adrenaline in adrenaline bitartrate injections.

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: ACS Omega Year: 2019 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: ACS Omega Year: 2019 Document type: Article Affiliation country: Country of publication: