Discordance between Flow-Cytometry Crossmatch and Single Antigen Bead (SAB) Assay: An Uncommon Finding and its Resolution.
Mehra, Simmi; Tiwari, Aseem Kumar; Aggarwal, Geet; Arora, Dinesh; Saini, Abhishek; Rajvanshi, Chhavi; Kumari, Poonam; Dorwal, Pranav.
Affiliation
  • Mehra S; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Tiwari AK; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Aggarwal G; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Arora D; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Saini A; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Rajvanshi C; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Kumari P; Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon, Haryana, India.
  • Dorwal P; Section Head, Flow Cytometry, Waikato Hospital, Hamilton, New Zealand.
Indian J Nephrol ; 30(1): 55-57, 2020.
Article in En | MEDLINE | ID: mdl-32015606

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Indian J Nephrol Year: 2020 Document type: Article Affiliation country: