Your browser doesn't support javascript.
loading
Predict respiratory distress syndrome by umbilical cord blood gas analysis in newborns with reassuring Apgar score.
De Bernardo, Giuseppe; De Santis, Rita; Giordano, Maurizio; Sordino, Desiree; Buonocore, Giuseppe; Perrone, Serafina.
Affiliation
  • De Bernardo G; Department of Pediatrics, Neonatology and Neonatal Intensive Care Unit, Buon Consiglio Fatebenefratelli Hospital, Via Manzoni 220, 80123, Napoli, Campania, Italy. pinodebtin@gmail.com.
  • De Santis R; School of specialization in Pediatrics, Catholic University of the Sacred Heart Faculty of Medicine and Surgery, Rome, Italy.
  • Giordano M; Faculty of Medicine, Federico II University, Naples, Italy.
  • Sordino D; Department of Emergency, NICU A.O.R.N. Santobono-Pausilipon, Naples, Italy.
  • Buonocore G; Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy.
  • Perrone S; Department of Medicine and Surgery, University of Parma, Parma, Italy.
Ital J Pediatr ; 46(1): 20, 2020 Feb 12.
Article in En | MEDLINE | ID: mdl-32050997
ABSTRACT

BACKGROUND:

Neonatal acidaemia at birth can increase neonatal morbidity and mortality and it is predictive of neonatal asphyxia. The umbilical blood gas analysis is a valid tool for the evaluation of neonatal acidaemia. However, umbilical cord blood gas analysis is commonly performed in high-risk situations or in the setting of Apgar scores < 7 at 5 min.

METHODS:

A retrospective cohort study was conducted from June to December 2018 at the Department of mother's and child's health, Poliambulanza Foundation Hospital Institute. Inclusion criteria were full term newborns with body weight appropriate for gestational age, born by vaginal delivery or caesarean section, reassuring Apgar Score > 7 at 5 min, arterial cord blood gas analysis showing pH < 7.4 or BE <-8 mmol/l or lactate > 6 mmol/l. The aim was to evaluate the predictive role of blood gas analysis for respiratory distress syndrome in newborns with reassuring Apgar Score.

RESULTS:

352 full term newborns were enrolled. Umbilical cord blood artery pH showed an association with respiratory distress syndrome (χ2(1) = 10,084, OR (95% CI) 3,9 × 10- 4(2,9 × 10- 6 - 0,048); p < 0,05). ROC curve revealed that the cut-off point of pH was 7.12, with a sensibility and specificity of 68 and 63%, respectively.

CONCLUSIONS:

Umbilical cord blood artery pH < 7.12 at birth is associated to respiratory distress syndrome in newborns. Blood gas analysis is an important instrument to help health care providers during assistance in the delivery room, but also to early identify newborns at high risk for respiratory distress syndrome and better manage the care of these newborns after birth.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Respiratory Distress Syndrome, Newborn / Fetal Blood Type of study: Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Infant / Male / Newborn / Pregnancy Country/Region as subject: Europa Language: En Journal: Ital J Pediatr Journal subject: PEDIATRIA Year: 2020 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Respiratory Distress Syndrome, Newborn / Fetal Blood Type of study: Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Infant / Male / Newborn / Pregnancy Country/Region as subject: Europa Language: En Journal: Ital J Pediatr Journal subject: PEDIATRIA Year: 2020 Document type: Article Affiliation country:
...