Your browser doesn't support javascript.
loading
Comparison of the ASTA MicroIDSys and VITEK MS matrix-assisted laser desorption/ionization time-of-flight mass spectrometry systems for identification of clinical bacteria and yeasts.
Jung, Jin; Kim, Soo-Young; Park, Yeon-Joon; Lee, Jaewoong; Suk, Hyun Soo; Ha, Sung Il; Shin, Jeong Seob; Park, Kang Gyun; Kim, Yeongsic.
Affiliation
  • Jung J; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Kim SY; Department of Laboratory Medicine, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, South Korea. Electronic address: vsykim@catholic.ac.kr.
  • Park YJ; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Lee J; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Suk HS; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Ha SI; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Shin JS; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Park KG; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Kim Y; Department of Laboratory Medicine, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, South Korea.
J Infect Chemother ; 26(12): 1328-1333, 2020 Dec.
Article in En | MEDLINE | ID: mdl-32855038
The ASTA MicroIDSys system (ASTA, Suwon, Korea) is a newly developed Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) system for identification of microorganisms. We compared the performance of the ASTA MicroIDSys system with that of the VITEK MS system (bioMérieux, Marcy l'Etoile, France) for identifying clinical microorganisms. A total 2055 isolates including 1910 bacteria and 145 yeasts were tested. Among them, the VITEK MS correctly identified 1999 (97.3%) isolates to species level and 26 (1.3%) to the genus level. The ASTA MicroIDSys correctly identified 1988 (96.7%) isolates to species level and 28 (1.4%) to the genus level. The VITEK MS and ASTA MicroIDSys misidentified one isolate and four (0.2%) isolates, respectively, and provided no identification for 29 (1.4%) and 35 (1.7%) isolates, respectively. The performance of the ASTA MicroIDSys was comparable to that of the VITEK MS for identification of clinically relevant bacterial and yeast isolates.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bacteria / Lasers Type of study: Diagnostic_studies Limits: Humans Country/Region as subject: Asia / Europa Language: En Journal: J Infect Chemother Journal subject: MICROBIOLOGIA / TERAPIA POR MEDICAMENTOS Year: 2020 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bacteria / Lasers Type of study: Diagnostic_studies Limits: Humans Country/Region as subject: Asia / Europa Language: En Journal: J Infect Chemother Journal subject: MICROBIOLOGIA / TERAPIA POR MEDICAMENTOS Year: 2020 Document type: Article Affiliation country: Country of publication: