Your browser doesn't support javascript.
loading
Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.
Fuller, Daniel; Colwell, Emily; Low, Jonathan; Orychock, Kassia; Tobin, Melissa Ann; Simango, Bo; Buote, Richard; Van Heerden, Desiree; Luan, Hui; Cullen, Kimberley; Slade, Logan; Taylor, Nathan G A.
Affiliation
  • Fuller D; School of Human Kinetics and Recreation, Memorial University, St. John's, NL, Canada.
  • Colwell E; Department of Computer Science, Memorial University, St. John's, NL, Canada.
  • Low J; Division of Community Health and Humanities, Faculty of Medicine, Memorial University, St. John's, NL, Canada.
  • Orychock K; School of Human Kinetics and Recreation, Memorial University, St. John's, NL, Canada.
  • Tobin MA; School of Human Kinetics and Recreation, Memorial University, St. John's, NL, Canada.
  • Simango B; School of Human Kinetics and Recreation, Memorial University, St. John's, NL, Canada.
  • Buote R; Faculty of Medicine, Memorial University, St. John's, NL, Canada.
  • Van Heerden D; School of Human Kinetics and Recreation, Memorial University, St. John's, NL, Canada.
  • Luan H; Faculty of Medicine, Memorial University, St. John's, NL, Canada.
  • Cullen K; Faculty of Engineering, Memorial University, St. John's, NL, Canada.
  • Slade L; Department of Geography, University of Oregon, Eugene, OR, United States.
  • Taylor NGA; School of Human Kinetics and Recreation, Memorial University, St. John's, NL, Canada.
JMIR Mhealth Uhealth ; 8(9): e18694, 2020 09 08.
Article in En | MEDLINE | ID: mdl-32897239
ABSTRACT

BACKGROUND:

Consumer-wearable activity trackers are small electronic devices that record fitness and health-related measures.

OBJECTIVE:

The purpose of this systematic review was to examine the validity and reliability of commercial wearables in measuring step count, heart rate, and energy expenditure.

METHODS:

We identified devices to be included in the review. Database searches were conducted in PubMed, Embase, and SPORTDiscus, and only articles published in the English language up to May 2019 were considered. Studies were excluded if they did not identify the device used and if they did not examine the validity or reliability of the device. Studies involving the general population and all special populations were included. We operationalized validity as criterion validity (as compared with other measures) and construct validity (degree to which the device is measuring what it claims). Reliability measures focused on intradevice and interdevice reliability.

RESULTS:

We included 158 publications examining nine different commercial wearable device brands. Fitbit was by far the most studied brand. In laboratory-based settings, Fitbit, Apple Watch, and Samsung appeared to measure steps accurately. Heart rate measurement was more variable, with Apple Watch and Garmin being the most accurate and Fitbit tending toward underestimation. For energy expenditure, no brand was accurate. We also examined validity between devices within a specific brand.

CONCLUSIONS:

Commercial wearable devices are accurate for measuring steps and heart rate in laboratory-based settings, but this varies by the manufacturer and device type. Devices are constantly being upgraded and redesigned to new models, suggesting the need for more current reviews and research.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Fitness Trackers / Wearable Electronic Devices Type of study: Health_economic_evaluation / Prognostic_studies / Systematic_reviews Limits: Humans Language: En Journal: JMIR Mhealth Uhealth Year: 2020 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Fitness Trackers / Wearable Electronic Devices Type of study: Health_economic_evaluation / Prognostic_studies / Systematic_reviews Limits: Humans Language: En Journal: JMIR Mhealth Uhealth Year: 2020 Document type: Article Affiliation country:
...