Your browser doesn't support javascript.
loading
A tandem giant magnetoresistance assay for one-shot quantification of clinically relevant concentrations of N-terminal pro-B-type natriuretic peptide in human blood.
Meng, Fanda; Huo, Weisong; Lian, Jie; Zhang, Lei; Shi, Xizeng; Jesorka, Aldo; Gao, Yunhua.
Affiliation
  • Meng F; Institute of Basic Medicine, The First Affiliated Hospital of Shandong First Medical University, Jinan, 250014, China. mengfind@163.com.
  • Huo W; Institute of Basic Medicine, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, 250062, China. mengfind@163.com.
  • Lian J; Department of Chemistry and Chemical Engineering, Chalmers University of Technology, SE-412 96, Gothenburg, Sweden. mengfind@163.com.
  • Zhang L; Dongguan Bosh Biotechnologies, Ltd., Dongguan, 523808, China.
  • Shi X; College of Criminal Investigation, People's Public Security University of China, Beijing, 100038, China.
  • Jesorka A; Dongguan Bosh Biotechnologies, Ltd., Dongguan, 523808, China.
  • Gao Y; Dongguan Bosh Biotechnologies, Ltd., Dongguan, 523808, China.
Anal Bioanal Chem ; 413(11): 2943-2949, 2021 May.
Article in En | MEDLINE | ID: mdl-33624128
ABSTRACT
We report a microfluidic sandwich immunoassay constructed around a dual-giant magnetoresistance (GMR) sensor array to quantify the heart failure biomarker NT-proBNP in human plasma at the clinically relevant concentration levels between 15 pg/mL and 40 ng/mL. The broad dynamic range was achieved by differential coating of two identical GMR sensors operated in tandem, and combining two standard curves. The detection limit was determined as 5 pg/mL. The assay, involving 53 plasma samples from patients with different cardiovascular diseases, was validated against the Roche Cobas e411 analyzer. The salient features of this system are its wide concentration range, low detection limit, small sample volume requirement (50 µL), and the need for a short measurement time of 15 min, making it a prospective candidate for practical use in point of care analysis.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Peptide Fragments / Immunoassay / Natriuretic Peptide, Brain / Lab-On-A-Chip Devices / Heart Failure Limits: Aged / Humans Language: En Journal: Anal Bioanal Chem Year: 2021 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Peptide Fragments / Immunoassay / Natriuretic Peptide, Brain / Lab-On-A-Chip Devices / Heart Failure Limits: Aged / Humans Language: En Journal: Anal Bioanal Chem Year: 2021 Document type: Article Affiliation country:
...