ABSTRACT
In the GAMMA 10/PDX tandem mirror, plasma with strong ion-temperature anisotropy is produced by using the ion cyclotron range of frequency waves. This anisotropy of ion temperature causes several Alfvén-Ion-Cyclotron (AIC) waves to spontaneously excite in the frequency range just below the ion cyclotron frequency. In addition, difference-frequency (DF) waves are excited in the radial inner region of the plasma by wave-wave coupling among the AIC waves. The radial density profiles were measured at multi-axial positions using a frequency-modulation reflectometer with an axial array of microwave antennas, and an axial variation of the density was found to be significant. In addition, a relative phase difference of the DF wave between axially separated two points was first obtained by finely choosing the probing frequency of the reflectometers with a maximum coherence used as a measure, indicating that the DF wave is a propagating wave, while the pump AIC waves are standing waves in the axial region of measurement.