Your browser doesn't support javascript.
loading
NATIONWIDE SURVEY OF RADIATION EXPOSURE FOR RADIOFREQUENCY CATHETER ABLATION FOR PULMONARY VEIN ISOLATION AND NONPULMONARY VEIN ISOLATION IN JAPAN.
Ishibashi, Toru; Masuda, Takanori; Kato, Mamoru; Yamashita, Yukari; Takei, Yasutaka; Tsukamoto, Atsuko; Matsumoto, Kazuma; Sakamoto, Hajime.
Affiliation
  • Ishibashi T; Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
  • Masuda T; Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
  • Kato M; Department of Radiological Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Naka-ku, Hiroshima 730-8655, Japan.
  • Yamashita Y; Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
  • Takei Y; Department of Radiological Technology, Faculty of Health Science and Technology, 288 Matsushima, Kurashiki-City, Okayama 701-0193, Japan.
  • Tsukamoto A; Department of Radiology, NTT Medical Center Tokyo, 5-9-22 Higashi-Gotanda, Shinagawa-ku, Tokyo 141-8625, Japan.
  • Matsumoto K; Department of Clinical Radiology, Hyogo College of Medicine College Hospital, 1-3-6 Minatojima, Chuo-ku, Kobe City, Hyogo 663-8501, Japan.
  • Sakamoto H; Department of Radiological Technology, Faculty of Health Science, Juntendo University, 2-1-1 Hongo, bunkyou-ku, Tokyo 113-8421, Japan.
Radiat Prot Dosimetry ; 198(1-2): 16-22, 2022 Feb 18.
Article in En | MEDLINE | ID: mdl-35021232
To propose typical values for the arrhythmia region between pulmonary vein isolation (PVI) and nonpulmonary vein isolation (non-PVI) in Japan. A nationwide questionnaire was posted to 343 facilities, to which 125 facilities (36.4%) responded. Results is the median for PVI and non-PVI were in terms of Ka,r (317 and 196 mGy), PKA (40.8 and 26.3 Gy.cm2), FT (43.0 and 27.3 min), and CI (326 and 102 images). When comparing PVI and non-PVI procedures, there were significant differences in Ka, r, PKA, FT, and CI (p < 0.05). In other words, by classifying into two types, PVI and non-PVI, we contributed to the establishment of typical values in Japan's RFCA.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pulmonary Veins / Atrial Fibrillation / Catheter Ablation / Radiation Exposure Limits: Humans Country/Region as subject: Asia Language: En Journal: Radiat Prot Dosimetry Year: 2022 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pulmonary Veins / Atrial Fibrillation / Catheter Ablation / Radiation Exposure Limits: Humans Country/Region as subject: Asia Language: En Journal: Radiat Prot Dosimetry Year: 2022 Document type: Article Affiliation country: Country of publication: