Your browser doesn't support javascript.
loading
Rapid and label-free detection of Aflatoxin-B1viamicrofluidic electrochemical biosensor based on manganese (III) oxide (Mn3O4) synthesized by co-precipitation route at room temperature.
Singh, Avinash Kumar; Dhiman, Tarun Kumar; Lakshmi, G B V S; Raj, Rishi; Jha, Sandeep Kumar; Solanki, Pratima R.
Affiliation
  • Singh AK; Special Centre for Nanoscience, Jawaharlal Nehru University (JNU), New Delhi-110067, India.
  • Dhiman TK; School of Physical Sciences, JNU, New Delhi-110067, India.
  • Lakshmi GBVS; Special Centre for Nanoscience, Jawaharlal Nehru University (JNU), New Delhi-110067, India.
  • Raj R; Special Centre for Nanoscience, Jawaharlal Nehru University (JNU), New Delhi-110067, India.
  • Jha SK; Indian Institute of Technology, New Delhi-110067, India.
  • Solanki PR; Indian Institute of Technology, New Delhi-110067, India.
Nanotechnology ; 33(28)2022 Apr 22.
Article in En | MEDLINE | ID: mdl-35299158
ABSTRACT
Aflatoxin B1 (AFB1) is the most toxic mycotoxin, naturally occurring in food items, and it causes several types of lethal diseases. Therefore, a rapid and convenient detection method for AFB1 is the first step toward overcoming the effect of AFB1. The current work presents the development of an efficient microfluidic electrochemical-based biosensor using tri-manganese tetroxide nanoparticles (Mn3O4nps) for AFB1 detection. The Mn3O4nps were synthesized at room temperature through the co-precipitation route. Its phase purity, structural and morphological studies have been characterized through x-ray diffraction, Raman spectroscopy, energy-dispersive x-ray, Fourier transform infrared spectroscopy and transmission electron microscopy. The mask-less UV-lithography was carried out to fabricate the three-electrode chip and microfluidic channel of the microfluidic electrochemical biosensing system. The designed microfluidic immunosensor (BSA/Ab-AFB1/Mn3O4/ITO) was fabricated using the three-electrode chip, microfluidic channel in poly-dimethyl siloxane. The fabricated sensor exhibited the 3.4µA ml ng-1cm-2sensitivity and had the lowest lower detection limit of 0.295 pg ml-1with the detection range of 1 pg ml-1to 300 ng ml-1. Additionally, the spiked study was also performed with this immunoelectrode and a recovery rate was obtained of 108.2%.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Aflatoxins Type of study: Diagnostic_studies Language: En Journal: Nanotechnology Year: 2022 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Aflatoxins Type of study: Diagnostic_studies Language: En Journal: Nanotechnology Year: 2022 Document type: Article Affiliation country: