Measuring the Area of the Interventricular Septum in the 4-Chamber View: A New Technique to Evaluate the Fetus at Risk for Septal Hypertrophy.
J Ultrasound Med
; 41(12): 2939-2953, 2022 Dec.
Article
in En
| MEDLINE
| ID: mdl-35305032
ABSTRACT
OBJECTIVES:
One of the problems for the clinician who desires to measure the interventricular septum (IVS) in a high-risk fetus is to know where to make the measurement. The purpose of this study was to use speckle-tracking analysis to measure the IVS area, 24-segment widths, and length at end-diastole (ED) and end-systole (ES) in normal fetuses.METHODS:
From the 4-chamber view, speckle-tracking analysis was performed at ED and ES on the IVS in 200 normal fetuses. The following were computed and regressed against gestational age (GA) and fetal biometric (FB) measurements area, length, and the 24-segment transverse widths from the apex to the crux. The 24-segment width/length ratio was also measured. The speckle-tracking measurements of the ED area and length were compared using a point-to-point measurement tool available on all ultrasound machines.RESULTS:
The ED and ES areas, lengths, and 24-segment widths increased with GA and FB. The ED and ES areas were virtually identical. The 24-segment width/length ratio decreased from the apex to the crux of the septum. There was no significant difference in the measurement of the ED area and the length between speckle-tracking and the point-to-point measurements.CONCLUSIONS:
Measurement of the area and length of the IVS are simple to obtain and provide a new diagnostic tool to evaluate the fetus at risk for IVS hypertrophy which may be observed in fetuses of mothers with pregestational and gestational diabetes.Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Ventricular Septum
/
Fetal Heart