Your browser doesn't support javascript.
loading
Theory for a non-invasive diagnostic biomarker for craniospinal diseases.
Karimi, Fariba; Neufeld, Esra; Fallahi, Arya; Boraschi, Andrea; Zwanenburg, Jaco J M; Spiegelberg, Andreas; Kurtcuoglu, Vartan; Kuster, Niels.
Affiliation
  • Karimi F; Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland. Electronic address: karimi@itis.swiss.
  • Neufeld E; Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.
  • Fallahi A; Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.
  • Boraschi A; The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland.
  • Zwanenburg JJM; Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Spiegelberg A; The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland.
  • Kurtcuoglu V; The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland; Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland.
  • Kuster N; Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.
Neuroimage Clin ; 37: 103280, 2023.
Article in En | MEDLINE | ID: mdl-36508887
Monitoring intracranial pressure (ICP) and craniospinal compliance (CC) is frequently required in the treatment of patients suffering from craniospinal diseases. However, current approaches are invasive and cannot provide continuous monitoring of CC. Dynamic exchange of blood and cerebrospinal fluid (CSF) between cranial and spinal compartments due to cardiac action transiently modulates the geometry and dielectric properties of the brain. The resulting impedance changes can be measured and might be usable as a non-invasive CC surrogate. A numerically robust and computationally efficient approach based on the reciprocity theorem was developed to compute dynamic impedance changes resulting from small geometry and material property changes. The approach was successfully verified against semi-analytical benchmarks, before being combined with experimental brain pulsation data to study the information content of the impedance variation. The results indicate that the measurable signal is dominated by the pulsatile displacement of the cortical brain surface, with minor contributions from the ventricular surfaces and from changes in brain perfusion. Different electrode setups result in complementary information. The information content from the investigated three electrode pairs was employed to successfully infer subject-specific brain pulsation and motion features. This suggests that non-invasive CC surrogates based on impedance monitoring could be established.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Intracranial Pressure Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Neuroimage Clin Year: 2023 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Intracranial Pressure Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Neuroimage Clin Year: 2023 Document type: Article Country of publication: