Your browser doesn't support javascript.
loading
Multi-Scope Feature Extraction for Intracranial Aneurysm 3D Point Cloud Completion.
Ma, Wuwei; Yang, Xi; Wang, Qiufeng; Huang, Kaizhu; Huang, Xiaowei.
Affiliation
  • Ma W; School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou 215123, China.
  • Yang X; School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou 215123, China.
  • Wang Q; School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou 215123, China.
  • Huang K; Data Science Research Center, Duke Kunshan University, Kunshan 215316, China.
  • Huang X; Department of Computer Science, University of Liverpool, Liverpool L69 3BX, UK.
Cells ; 11(24)2022 12 17.
Article in En | MEDLINE | ID: mdl-36552872
ABSTRACT
3D point clouds are gradually becoming more widely used in the medical field, however, they are rarely used for 3D representation of intracranial vessels and aneurysms due to the time-consuming data reconstruction. In this paper, we simulate the incomplete intracranial vessels (including aneurysms) in the actual collection from different angles, then propose Multi-Scope Feature Extraction Network (MSENet) for Intracranial Aneurysm 3D Point Cloud Completion. MSENet adopts a multi-scope feature extraction encoder to extract the global features from the incomplete point cloud. This encoder utilizes different scopes to fuse the neighborhood information for each point fully. Then a folding-based decoder is applied to obtain the complete 3D shape. To enable the decoder to intuitively match the original geometric structure, we engage the original points coordinates input to perform residual linking. Finally, we merge and sample the complete but coarse point cloud from the decoder to obtain the final refined complete 3D point cloud shape. We conduct extensive experiments on both 3D intracranial aneurysm datasets and general 3D vision PCN datasets. The results demonstrate the effectiveness of the proposed method on three evaluation metrics compared to baseline our model increases the F-score to 0.379 (+21.1%)/0.320 (+7.7%), reduces Chamfer Distance score to 0.998 (-33.8%)/0.974 (-6.4%), and reduces the Earth Mover's Distance to 2.750 (17.8%)/2.858 (-0.8%).
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Intracranial Aneurysm Type of study: Prognostic_studies Limits: Humans Language: En Journal: Cells Year: 2022 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Intracranial Aneurysm Type of study: Prognostic_studies Limits: Humans Language: En Journal: Cells Year: 2022 Document type: Article Affiliation country:
...