Your browser doesn't support javascript.
loading
[99mTc]Technetium-Labeled Niosomes: Radiolabeling, Quality Control, and In Vitro Evaluation.
Ekinci, Meliha; Çaliskan, Emine Esin; Çakar, Burak; Ilem-Özdemir, Derya; Uyanikgil, Yigit; Çetin Uyanikgil, Emel Öykü.
Affiliation
  • Ekinci M; Faculty of Pharmacy, Department of Radiopharmacy, Ege University, Bornova, 35040 Izmir, Türkiye.
  • Çaliskan EE; Faculty of Pharmacy, Department of Pharmaceutical Technology, Department of Biopharmaceutics and Pharmacokinetics, Ege University, 35100 Izmir, Türkiye.
  • Çakar B; Faculty of Medicine, Department of Histology and Embryology, Ege University, 35040 Izmir, Türkiye.
  • Ilem-Özdemir D; Faculty of Pharmacy, Department of Radiopharmacy, Ege University, Bornova, 35040 Izmir, Türkiye.
  • Uyanikgil Y; Faculty of Medicine, Department of Histology and Embryology, Ege University, 35040 Izmir, Türkiye.
  • Çetin Uyanikgil EÖ; Health Science Institute, Department of Stem Cell, Ege University, 35040 Izmir, Türkiye.
ACS Omega ; 8(7): 6279-6288, 2023 Feb 21.
Article in En | MEDLINE | ID: mdl-36844604
ABSTRACT
The aim of this research was to develop technetium-99m ([99mTc]Tc)-radiolabeled niosomes and evaluate the cancer cell incorporation capacity of radiolabeled niosomes. For this purpose, niosome formulations were developed by film hydration method, and prepared niosomes were characterized to particle size, polydispersity index (PdI), ζ-potential value, and image profile. Then, niosomes were radiolabeled with [99mTc]Tc using stannous salts (chloride) as a reducing agent. The radiochemical purity (RP) and stability in different mediums of the niosomes were assessed by ascending radioactive thin-layer chromatography (RTLC) and radioactive ultrahigh-performance liquid chromatography (R-UPLC) methods. Also, the partition coefficient value of radiolabeled niosomes was determined. The cell incorporation of [99mTc]Tc-labeled niosome formulations, as well as reduced/hydrolyzed (R/H)-[99mTc]NaTcO4 in the HT-29 (human colorectal adenocarcinoma) cells, was then assessed. According to the obtained results, the spherical niosomes had a particle size of 130.5 ± 1.364 nm, a PdI value of 0.250 ± 0.023, and a negative charge of -35.4 ± 1.06 mV. The niosome formulations were effectively radiolabeled with [99mTc]Tc using 500 µg mL-1 stannous chloride for 15 min, and RP was found to be over 95%. [99mTc]Tc-niosomes showed good in vitro stability in every system for up to 6 h. The log P value of radiolabeled niosomes was found as -0.66 ± 0.02. Compared to R/H-[99mTc]NaTcO4 (34.18 ± 1.56%), the incorporation percentages of [99mTc]Tc-niosomes (88.45 ± 2.54%) were shown to be higher in cancer cells. In conclusion, the newly developed [99mTc]Tc-niosomes showed good prototype for potential use in nuclear medicine imaging in the near future. However, further investigations, such as drug encapsulation and biodistribution studies, should be performed, and our studies are continuing.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ACS Omega Year: 2023 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ACS Omega Year: 2023 Document type: Article