Your browser doesn't support javascript.
loading
Latent signal models: Learning compact representations of signal evolution for improved time-resolved, multi-contrast MRI.
Arefeen, Yamin; Xu, Junshen; Zhang, Molin; Dong, Zijing; Wang, Fuyixue; White, Jacob; Bilgic, Berkin; Adalsteinsson, Elfar.
Affiliation
  • Arefeen Y; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Xu J; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Zhang M; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Dong Z; Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • Wang F; Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • White J; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Bilgic B; Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • Adalsteinsson E; Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA.
Magn Reson Med ; 90(2): 483-501, 2023 08.
Article in En | MEDLINE | ID: mdl-37093775
PURPOSE: To improve time-resolved reconstructions by training auto-encoders to learn compact representations of Bloch-simulated signal evolution and inserting the decoder into the forward model. METHODS: Building on model-based nonlinear and linear subspace techniques, we train auto-encoders on dictionaries of simulated signal evolution to learn compact, nonlinear, latent representations. The proposed latent signal model framework inserts the decoder portion of the auto-encoder into the forward model and directly reconstructs the latent representation. Latent signal models essentially serve as a proxy for fast and feasible differentiation through the Bloch equations used to simulate signal. This work performs experiments in the context of T2 -shuffling, gradient echo EPTI, and MPRAGE-shuffling. We compare how efficiently auto-encoders represent signal evolution in comparison to linear subspaces. Simulation and in vivo experiments then evaluate if reducing degrees of freedom by incorporating our proxy for the Bloch equations, the decoder portion of the auto-encoder, into the forward model improves reconstructions in comparison to subspace constraints. RESULTS: An auto-encoder with 1 real latent variable represents single-tissue fast spin echo, EPTI, and MPRAGE signal evolution to within 0.15% normalized RMS error, enabling reconstruction problems with 3 degrees of freedom per voxel (real latent variable + complex scaling) in comparison to linear models with 4-8 degrees of freedom per voxel. In simulated/in vivo T2 -shuffling and in vivo EPTI experiments, the proposed framework achieves consistent quantitative normalized RMS error improvement over linear approaches. From qualitative evaluation, the proposed approach yields images with reduced blurring and noise amplification in MPRAGE-shuffling experiments. CONCLUSION: Directly solving for nonlinear latent representations of signal evolution improves time-resolved MRI reconstructions.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Algorithms / Magnetic Resonance Imaging Type of study: Prognostic_studies / Qualitative_research Language: En Journal: Magn Reson Med Journal subject: DIAGNOSTICO POR IMAGEM Year: 2023 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Algorithms / Magnetic Resonance Imaging Type of study: Prognostic_studies / Qualitative_research Language: En Journal: Magn Reson Med Journal subject: DIAGNOSTICO POR IMAGEM Year: 2023 Document type: Article Affiliation country: Country of publication: