Your browser doesn't support javascript.
loading
Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19.
Yadav, Shalu; Sadique, Mohd Abubakar; Ranjan, Pushpesh; Khan, Raju.
Affiliation
  • Yadav S; CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India.
  • Sadique MA; CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India.
  • Ranjan P; CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India.
  • Khan R; CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India. Electronic address: khan.raju@gmail.com.
Anal Chim Acta ; 1265: 341326, 2023 Jul 18.
Article in En | MEDLINE | ID: mdl-37230571
Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Metal Nanoparticles / COVID-19 / Graphite Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Anal Chim Acta Year: 2023 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Metal Nanoparticles / COVID-19 / Graphite Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Anal Chim Acta Year: 2023 Document type: Article Affiliation country: Country of publication: