Your browser doesn't support javascript.
loading
Determination of antioxidant activity by in situ synthesis of AgNPs using in-tube SPME coupled on-line to capillary liquid chromatography.
Prieto-Blanco, María Carmen; Pardo-Puñal, María; Moliner-Martínez, Yolanda; Campíns-Falcó, Pilar.
Affiliation
  • Prieto-Blanco MC; Grupo QANAP, Departamento de Química, Facultade de Ciencias, Instituto Universitario de Medio Ambiente (IUMA), Universidade da Coruña, Campus da Zapateira, 15071, A Coruña, Spain. m.c.prieto.blanco@udc.gal.
  • Pardo-Puñal M; Grupo MINTOTA, Departament de Química Analítica, Facultat de Química, Universitat de Valencia C/ Dr. Moliner 50, E46100, Burjassot, Valencia, Spain.
  • Moliner-Martínez Y; Grupo MINTOTA, Departament de Química Analítica, Facultat de Química, Universitat de Valencia C/ Dr. Moliner 50, E46100, Burjassot, Valencia, Spain.
  • Campíns-Falcó P; Grupo MINTOTA, Departament de Química Analítica, Facultat de Química, Universitat de Valencia C/ Dr. Moliner 50, E46100, Burjassot, Valencia, Spain.
Mikrochim Acta ; 190(8): 299, 2023 07 18.
Article in En | MEDLINE | ID: mdl-37462815
ABSTRACT
A chromatographic system based on in-tube SPME coupled to capillary LC-DAD has been used to study the synthesis of silver nanoparticles using polyphenols in different scenarios excess of the reducing agent or of the silver salt, addition of the cationic surfactants, and thermal synthesis. The optimized synthesis conditions allowed to quantify the polyphenols used as reducing agents, such as Trolox and chlorogenic acid. Two chromatographic peaks with different absorption spectrum were monitored during the syntheses. Depending on the molar relationship, a linear relation between the area of the chromatographic peaks and the concentration of the silver or polyphenol was established. For stabilization of silver nanoparticles, different cationic surfactants were used allowing to evaluate the role of anion (chloride and bromide) and of the alkyl chain. The proposed methodology can be used to determine chlorogenic acid up to 3 mM with a detection limit of 34 µM at λ= 400 nm. Chlorogenic acid was determined in dietary products with successful results. Precision (RSD=10%) and recovery (97-100%) were also satisfactory.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Metal Nanoparticles / Antioxidants Language: En Journal: Mikrochim Acta Year: 2023 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Metal Nanoparticles / Antioxidants Language: En Journal: Mikrochim Acta Year: 2023 Document type: Article Affiliation country: